W DOC AIRBUS | AMM A320F

Check Clogging Indicators on Return, Case Drain, Ground Servicing, HP Delivery, HP Bleed Air and LP Bleed Air, Water Separator Filters and Reservoir Pressurization Filter


TASK 29-10-00-210-002-A
Check Clogging Indicators on Return, Case Drain, Ground Servicing, HP Delivery, HP Bleed Air and LP Bleed Air, Water Separator Filters and Reservoir Pressurization Filter


WARNING: OBEY THE HYDRAULIC SAFETY PROCEDURES.
WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
ZONE: 100
ZONE: 195
ZONE: 196
ZONE: 197
ZONE: 734
FIN: 1002GM
FIN: 1048GM
FIN: 1084GM
FIN: 1132GM
FIN: 1360GM
FIN: 2002GM
FIN: 2048GM
FIN: 2084GM
FIN: 3002GM
FIN: 3048GM
FIN: 3084GM
1. Reason for the Job
Refer to the MPD TASK: 290000-05
CHECK CLOGGING INDICATORS ON RETURN, CASE DRAIN, GROUND SERVICING, HP DELIVERY, HP BLEED AIR AND LP BLEED AIR WATER SEPARATOR FILTERS AND RESERVOIR PRESSURIZATION FILTER.
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
100
LOWER HALF FUSELAGE INCLUDING RADOME
195
HYDRAULIC COMPT AND FAIRINGS
196
HYDRAULIC COMPT AND FAIRINGS
197
REAR FAIRING
734
MAIN DOOR
195BB, 196BB, 197CB, 197FB, 437AL, 438AR, 447AL, 448AR
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 29-11-00-710-001-A
Operational Test of the Green Hydraulic System
TASK 29-11-43-000-011-A
Removal of the Differential Pressure Indicator (DPI)
TASK 29-11-43-000-042-A
Removal of the Engine-Pump Case-Drain Filter Differential Pressure Indicator
TASK 29-11-43-000-043-A
Removal of the Engine-Pump Case-Drain Filter Differential Pressure Indicator
TASK 29-11-43-400-011-A
Installation of the Differential Pressure Indicator (DPI)
TASK 29-11-43-400-042-A
Installation of the Engine-Pump Case-Drain Filter Differential Pressure Indicator
TASK 29-11-43-400-043-A
Installation of the Engine-Pump Case-Drain Filter Differential Pressure Indicator
TASK 29-11-43-610-010-A
Servicing of the Engine-Pump Case-Drain Filter
TASK 29-11-43-610-040-A
Servicing of the Engine-Pump Case-Drain Filter
TASK 29-11-43-610-041-A
Servicing the Engine-Pump Case-Drain Filter
TASK 29-11-43-610-802-A
Servicing of the Engine-Pump Case-Drain Filter
TASK 29-11-44-610-001-A
Servicing of the LP-Filter
TASK 29-11-44-960-001-A
Replacement of the Clogging Indicator
TASK 29-11-45-610-001-A
Servicing of the HP-Filter
TASK 29-11-45-960-001-A
Replacement of the Clogging Indicator
TASK 29-11-51-000-010-A
Removal of the Engine Pump
TASK 29-11-51-000-040-A
Removal of the Green Engine Pump
TASK 29-11-51-000-041-A
Removal of the Green Engine Pump
TASK 29-11-51-000-805-A
Removal of the Green Engine Driven Pump
TASK 29-11-51-400-010-A
Installation of the Engine Pump
TASK 29-11-51-400-040-A
Installation of the Green Engine Pump
TASK 29-11-51-400-041-A
Installation of the Green Engine Pump
TASK 29-11-51-400-805-A
Installation of the Green Engine-Driven Pump
TASK 29-12-00-710-001-A
Functional Check of Blue Electrical Pump Pressure by Reading ECAM Indication
TASK 29-12-43-610-001-A
Servicing of the Electric-Pump Case-Drain Filter
TASK 29-12-43-960-001-A
Replacement of the Clogging Indicator
TASK 29-12-44-610-001-A
Servicing of the LP-Filter
TASK 29-12-44-960-001-A
Replacement of the Clogging Indicator
TASK 29-12-45-610-001-A
Servicing of the HP-Filter
TASK 29-12-45-960-001-A
Replacement of the Clogging Indicator
TASK 29-12-51-000-001-A
Removal of the Electric Pump
TASK 29-12-51-400-001-A
Installation of the Electric Pump
TASK 29-13-00-710-002-A
Operational Test of the Yellow Hydraulic System
TASK 29-13-43-000-012-A
Removal of the Differential Pressure Indicator (DPI)
TASK 29-13-43-000-805-A
Removal of the Engine-Pump Case-Drain Filter Differential Pressure Indicator (DPI)
TASK 29-13-43-400-012-A
Installation of the Differential Pressure Indicator (DPI)
TASK 29-13-43-400-805-A
Installation of the Engine-Pump Case-Drain Filter Differential Pressure Indicator (DPI)
TASK 29-13-43-610-010-A
Servicing of the Engine-Pump Case-Drain Filter
TASK 29-13-43-610-040-A
Servicing of the Engine Pump Case-Drain Filter
TASK 29-13-43-610-041-A
Servicing of the Engine Pump Case-Drain Filter
TASK 29-13-43-610-802-A
Servicing of the Engine-Pump Case-Drain Filter
TASK 29-13-44-610-001-A
Servicing of the LP-Filter
TASK 29-13-44-960-001-A
Replacement of the Clogging Indicator
TASK 29-13-45-610-001-A
Servicing of the HP-Filter
TASK 29-13-45-960-001-A
Replacement of the Clogging Indicator
TASK 29-13-51-000-003-A
Removal of the Yellow Engine Pump
TASK 29-13-51-000-004-A
Removal of the Yellow Engine Pump
TASK 29-13-51-000-010-A
Removal of the Engine Pump
TASK 29-13-51-000-806-A
Removal of the Yellow Engine Driven Pump
TASK 29-13-51-400-003-A
Installation of the Yellow Engine Pump
TASK 29-13-51-400-004-A
Installation of the Yellow Engine Pump
TASK 29-13-51-400-010-A
Installation of the Engine Pump
TASK 29-13-51-400-806-A
Installation of the Yellow Engine-Driven Pump
TASK 29-14-00-720-001-A
Functional Test of the Pressurizing System of the Hydraulic Reservoirs
TASK 29-14-41-000-002-A
Removal of the Reservoir Pressurization Unit
TASK 29-14-41-000-803-A
Removal of the Differential Pressure Indicator
TASK 29-14-41-400-002-A
Installation of the Reservoir Pressurization Unit
TASK 29-14-41-400-803-A
Installation of the Differential Pressure Indicator
TASK 29-14-41-610-002-A
Servicing of the Reservoir Pressurization Filter
TASK 29-14-42-000-002-A
Removal of the Filter Element of the Water Separator
TASK 29-14-42-400-002-A
Installation of the Filter Element of the Water Separator
TASK 29-16-11-610-001-A
Servicing of the HP-Filter
TASK 29-16-11-960-001-A
Replacement of the Clogging Indicator
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
TASK 32-12-00-410-001-A
Close the Main Gear Doors after Access
TASK 71-13-00-010-040-A
Opening of the Fan Cowl Doors
TASK 71-13-00-010-040-B
Opening of the Fan Cowl Doors
TASK 71-13-00-010-802-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
TASK 71-13-00-410-040-B
Closing of the Fan Cowl Doors
TASK 71-13-00-410-802-A
Closing of the Fan Cowl Doors
F Location of the Filters ** ON A/C NOT FOR ALL
F Location of the Filters ** ON A/C NOT FOR ALL
F Location of the Filters ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 29-10-00-010-075-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) Open one main door of the main gear (Ref. AMM TASK 32-12-00-010-001).
   (2) Open access doors 195BB 196BB 197CB 197FB.
   (3) Open fan cowl doors 437AL 438AR 447AL 448AR (Ref. AMM D/O 71-13-00-01).
Subtask 29-10-00-010-075-B ** ON A/C NOT FOR ALL
A. Get Access
   (1) Open one main door of the main gear (Ref. AMM TASK 32-12-00-010-001).
   (2) Open access doors 195BB 196BB 197CB 197FB.
   (3) Open fan cowl doors 437AL 438AR 447AL 448AR (Ref. AMM TASK 71-13-00-010-040).
Subtask 29-10-00-010-075-C ** ON A/C NOT FOR ALL
A. Get Access
   (1) Open one main door of the main gear (Ref. AMM TASK 32-12-00-010-001).
   (2) Open access doors 195BB 196BB 197CB 197FB.
   (3) Open fan cowl doors 437AL 438AR 447AL 448AR (Ref. AMM TASK 71-13-00-010-802).
Subtask 29-10-00-010-075-D ** ON A/C NOT FOR ALL
A. Get Access
   (1) Open one main door of the main gear (Ref. AMM TASK 32-12-00-010-001).
   (2) Open access doors 195BB 196BB 197CB 197FB.
   (3) Open fan cowl doors 437AL 438AR 447AL 448AR (Ref. AMM TASK 71-13-00-010-040).
4. Procedure
Subtask 29-10-00-210-059-A
A. Do a Check of the Clogging Indicators of the Hydraulic System Filters
   (1) Use the procedures that follow to look at the clogging indicators of these filters:
  • The low pressure (return) filter (1002GM) of the Green hydraulic system
  • The high pressure (delivery) filter (1048GM) of the Green hydraulic system
  • The case drain filter (2084GM) of the electric pump of the Blue hydraulic system
  • The low pressure (return) filter (2002GM) of the Blue hydraulic system
  • The high pressure (delivery) filter (2048GM) of the Blue hydraulic system
  • The low pressure (return) filter (3002GM) of the Yellow hydraulic system
  • The high pressure (delivery) filter (3048GM) of the Yellow hydraulic system
  • The (ground service) filter (1132GM) of the reservoir filling system
  • The reservoir pressurization filter of the reservoir pressurization unit (1360GM)
  • The water separator filter of the reservoir pressurization unit (1360GM).
  • The engine driven pump (EDP) case drain filter (1084GM) of the Green hydraulic system.
  • The EDP case drain filter (3084GM) of the Yellow hydraulic system.
Subtask 29-10-00-210-060-A ** ON A/C NOT FOR ALL
B. Check of the Filters in the Green Hydraulic System
   (1) For the low pressure (return) filter (1002GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no more maintenance is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do an operational test of the Green hydraulic system (Ref. AMM TASK 29-11-00-710-001).
       3 If the red indicator button is out (after the operational test):
         a Push the red indicator button in to set it again.
         b Replace the filter element (Ref. AMM TASK 29-11-44-610-001).
       4 If the red indicator button is not out (after the operational test):
         a Do a check the clogging indicator again after the next flight, if the red indicator button is out:
         b Do a check the clogging indicator again in less than 5 flight cycles (FC), if the red indicator button is out:
   (2) For the high pressure (delivery) filter (1048GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no more maintenance is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do an operational test of the Green hydraulic system (Ref. AMM TASK 29-11-00-710-001).
       3 If the red indicator button is out (after the operational test):
         a Push the red indicator button in to set it again.
         b Replace the filter element (Ref. AMM TASK 29-11-45-610-001).
       4 If the red indicator button is not out (after the operational test):
         a Do a check the clogging indicator again after the next flight, if the red indicator button is out:
         b Do a check the red indicator button again in less than five FC, if the red indicator button is out:
   (3) For the EDP case drain filter (1084GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no more maintenance is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do an operational test of the Green hydraulic system (Ref. AMM TASK 29-11-00-710-001).
       3 If the red indicator button is out (after the operational test):
         a Push the red indicator button in to set it again.
         b Replace the cartridge of the related case drain filter (Ref. AMM TASK 29-11-43-610-010).
         c Examine the removed cartridge for contamination:
       4 If the red indicator button is not out (after the operational test):
         a Do a check the clogging indicator again after the next flight, if the red indicator button is out:
         b Examine the removed cartridge for contamination:
         c Do a check the red indicator button again in less than five FC, if the red indicator button is out:
Subtask 29-10-00-210-060-B ** ON A/C NOT FOR ALL
B. Check of the Filters in the Green Hydraulic System
   (1) For the low pressure (return) filter (1002GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no more maintenance is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do an operational test of the Green hydraulic system (Ref. AMM TASK 29-11-00-710-001).
       3 If the red indicator button is out (after the operational test):
         a Push the red indicator button in to set it again.
         b Replace the filter element (Ref. AMM TASK 29-11-44-610-001).
       4 If the red indicator button is not out (after the operational test):
         a Do a check the clogging indicator again after the next flight, if the red indicator button is out:
         b Do a check the clogging indicator again in less than 5 flight cycles (FC), if the red indicator button is out:
   (2) For the high pressure (delivery) filter (1048GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no more maintenance is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do an operational test of the Green hydraulic system (Ref. AMM TASK 29-11-00-710-001).
       3 If the red indicator button is out (after the operational test):
         a Push the red indicator button in to set it again.
         b Replace the filter element (Ref. AMM TASK 29-11-45-610-001).
       4 If the red indicator button is not out (after the operational test):
         a Do a check the clogging indicator again after the next flight, if the red indicator button is out:
         b Do a check the red indicator button again in less than five FC, if the red indicator button is out:
   (3) For the EDP case drain filter (1084GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no more maintenance is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do an operational test of the Green hydraulic system (Ref. AMM TASK 29-11-00-710-001).
       3 If the red indicator button is out (after the operational test):
         a Push the red indicator button in to set it again.
         b Replace the cartridge of the related case drain filter (Ref. AMM TASK 29-11-43-610-040).
         c Examine the removed cartridge for contamination:
       4 If the red indicator button is not out (after the operational test):
         a Do a check the clogging indicator again after the next flight, if the red indicator button is out:
         b Examine the removed cartridge for contamination:
         c Do a check the red indicator button again in less than five FC, if the red indicator button is out:
Subtask 29-10-00-210-060-C ** ON A/C NOT FOR ALL
B. Check of the Filters in the Green Hydraulic System
   (1) For the low pressure (return) filter (1002GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no more maintenance is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do an operational test of the Green hydraulic system (Ref. AMM TASK 29-11-00-710-001).
       3 If the red indicator button is out (after the operational test):
         a Push the red indicator button in to set it again.
         b Replace the filter element (Ref. AMM TASK 29-11-44-610-001).
       4 If the red indicator button is not out (after the operational test):
         a Do a check the clogging indicator again after the next flight, if the red indicator button is out:
         b Do a check the clogging indicator again in less than 5 flight cycles (FC), if the red indicator button is out:
   (2) For the high pressure (delivery) filter (1048GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no more maintenance is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do an operational test of the Green hydraulic system (Ref. AMM TASK 29-11-00-710-001).
       3 If the red indicator button is out (after the operational test):
         a Push the red indicator button in to set it again.
         b Replace the filter element (Ref. AMM TASK 29-11-45-610-001).
       4 If the red indicator button is not out (after the operational test):
         a Do a check the clogging indicator again after the next flight, if the red indicator button is out:
         b Do a check the red indicator button again in less than five FC, if the red indicator button is out:
   (3) For the EDP case drain filter (1084GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no more maintenance is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do an operational test of the Green hydraulic system (Ref. AMM TASK 29-11-00-710-001).
       3 If the red indicator button is out (after the operational test):
         a Push the red indicator button in to set it again.
         b Replace the cartridge of the related case drain filter (Ref. AMM TASK 29-11-43-610-802).
         c Examine the removed cartridge for contamination:
       4 If the red indicator button is not out (after the operational test):
         a Do a check the clogging indicator again after the next flight, if the red indicator button is out:
         b Examine the removed cartridge for contamination:
Subtask 29-10-00-210-060-D ** ON A/C NOT FOR ALL
B. Check of the Filters in the Green Hydraulic System
   (1) For the low pressure (return) filter (1002GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no more maintenance is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do an operational test of the Green hydraulic system (Ref. AMM TASK 29-11-00-710-001).
       3 If the red indicator button is out (after the operational test):
         a Push the red indicator button in to set it again.
         b Replace the filter element (Ref. AMM TASK 29-11-44-610-001).
       4 If the red indicator button is not out (after the operational test):
         a Do a check the clogging indicator again after the next flight, if the red indicator button is out:
         b Do a check the clogging indicator again in less than 5 flight cycles (FC), if the red indicator button is out:
   (2) For the high pressure (delivery) filter (1048GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no more maintenance is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do an operational test of the Green hydraulic system (Ref. AMM TASK 29-11-00-710-001).
       3 If the red indicator button is out (after the operational test):
         a Push the red indicator button in to set it again.
         b Replace the filter element (Ref. AMM TASK 29-11-45-610-001).
       4 If the red indicator button is not out (after the operational test):
         a Do a check the clogging indicator again after the next flight, if the red indicator button is out:
         b Do a check the red indicator button again in less than five FC, if the red indicator button is out:
   (3) For the EDP case drain filter (1084GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no more maintenance is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do an operational test of the Green hydraulic system (Ref. AMM TASK 29-11-00-710-001).
       3 If the red indicator button is out (after the operational test):
         a Push the red indicator button in to set it again.
         b Replace the cartridge of the related case drain filter (Ref. AMM TASK 29-11-43-610-041).
         c Examine the removed cartridge for contamination:
       4 If the red indicator button is not out (after the operational test):
         a Do a check the clogging indicator again after the next flight, if the red indicator button is out:
         b Examine the removed cartridge for contamination:
         c Do a check the red indicator button again in less than five FC, if the red indicator button is out:
Subtask 29-10-00-210-061-A
C. Do a Check of the Filters in the Blue Hydraulic System
   (1) For the case drain filter (2084GM) of the electric pump:
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no further action is necessary.
       2 If the red indicator is out:
         a Push the red indicator button in to set it again.
         b Do the functional check of the Blue hydraulic system (Ref. AMM TASK 29-12-00-710-001).
       3 If the red indicator button is out (after the functional check):
         a Push the red indicator button in to set it again.
         b Replace the element of the related case drain filter (Ref. AMM TASK 29-12-43-610-001).
         c Examine the removed filter element for contamination:
       4 If the red indicator button is not out (after the functional check):
         a Check the clogging indicator again after the next flight, if the red indicator button is out:
         b Examine the removed filter element for contamination:
         c Check the red indicator button again in less than 5 FC, if the red indicator button is out:
   (2) For the low pressure (return) filter (2002GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no further action is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do the functional check of the Blue hydraulic system (Ref. AMM TASK 29-12-00-710-001).
       3 If the red indicator button is out (after the functional check):
         a Push the red indicator button in to set it again.
         b Replace the filter element (Ref. AMM TASK 29-12-44-610-001).
       4 If the red indicator button is not out (after the functional check):
         a Check the clogging indicator again after the next flight, if the red indicator button is out:
         b Check the red indicator button again in less than 5 FC, if the red indicator button is out:
   (3) For the high pressure (delivery) filter (2048GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no further action is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do the functional check of the Blue hydraulic system (Ref. AMM TASK 29-12-00-710-001).
       3 If the red indicator button is out (after the functional check):
         a Push the red indicator button in to set it again.
         b Replace the filter element (Ref. AMM TASK 29-12-45-610-001).
       4 If the red indicator button is not out (after the functional check):
         a Check the clogging indicator again after the next flight, if the red indicator button is out:
         b Check the red indicator button again in less than 5 FC, if the red indicator button is out:
Subtask 29-10-00-210-062-A ** ON A/C NOT FOR ALL
D. Do a Check of the Filters in the Yellow Hydraulic System
   (1) For the low pressure (return) filter (3002GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no more maintenance is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do an operational test of the Yellow hydraulic system (Ref. AMM TASK 29-13-00-710-002).
       3 If the red indicator button is out (after the operational test):
         a Push the red indicator button in to set it again.
         b Replace the filter element (Ref. AMM TASK 29-13-44-610-001).
       4 If the red indicator button is not out (after the operational test):
         a Do a check the clogging indicator again after the next flight, if the red indicator button is out:
         b Do a check the red indicator button again in less than five FC, if the red indicator button is out:
   (2) For the high pressure (delivery) filter (3048GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no more maintenance is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do an operational test of the Yellow hydraulic system (Ref. AMM TASK 29-13-00-710-002).
       3 If the red indicator button is out (after the operational test):
         a Push the red indicator button in to set it again.
         b Replace the filter element (Ref. AMM TASK 29-13-45-610-001).
       4 If the red indicator is not out (after the operational test):
         a Do a check the clogging indicator again after the next flight, if the red indicator button is out:
         b Do a check the red indicator button again in less than 5 FC, if the red indicator button is out:
   (3) For the EDP case drain filter (3084GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no more maintenance is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do an operational test of the Yellow hydraulic system (Ref. AMM TASK 29-13-00-710-002).
       3 If the red indicator button is out (after the operational test):
         a Push the red indicator button in to set it again.
         b Replace the cartridge of the related case drain filter (Ref. AMM TASK 29-13-43-610-010).
         c Examine the removed cartridge for contamination:
       4 If the red indicator button is not out (after the operational test):
         a Do a check the clogging indicator again after the next flight, if the red indicator button is out:
         b Examine the removed cartridge for contamination:
         c Do a check the red indicator button again in less than five FC, if the red indicator button is out:
Subtask 29-10-00-210-062-B ** ON A/C NOT FOR ALL
D. Do a Check of the Filters in the Yellow Hydraulic System
   (1) For the low pressure (return) filter (3002GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no more maintenance is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do an operational test of the Yellow hydraulic system (Ref. AMM TASK 29-13-00-710-002).
       3 If the red indicator button is out (after the operational test):
         a Push the red indicator button in to set it again.
         b Replace the filter element (Ref. AMM TASK 29-13-44-610-001).
       4 If the red indicator button is not out (after the operational test):
         a Do a check the clogging indicator again after the next flight, if the red indicator button is out:
         b Do a check the red indicator button again in less than five FC, if the red indicator button is out:
   (2) For the high pressure (delivery) filter (3048GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no more maintenance is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do an operational test of the Yellow hydraulic system (Ref. AMM TASK 29-13-00-710-002).
       3 If the red indicator button is out (after the operational test):
         a Push the red indicator button in to set it again.
         b Replace the filter element (Ref. AMM TASK 29-13-45-610-001).
       4 If the red indicator is not out (after the operational test):
         a Do a check the clogging indicator again after the next flight, if the red indicator button is out:
         b Do a check the red indicator button again in less than 5 FC, if the red indicator button is out:
   (3) For the EDP case drain filter (3084GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no more maintenance is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do an operational test of the Yellow hydraulic system (Ref. AMM TASK 29-13-00-710-002).
       3 If the red indicator button is out (after the operational test):
         a Push the red indicator button in to set it again.
         b Replace the cartridge of the related case drain filter (Ref. AMM TASK 29-13-43-610-040).
         c Examine the removed cartridge for contamination:
       4 If the red indicator button is not out (after the operational test):
         a Do a check the clogging indicator again after the next flight, if the red indicator button is out:
         b Examine the removed cartridge for contamination:
         c Do a check the red indicator button again in less than five FC, if the red indicator button is out:
Subtask 29-10-00-210-062-C ** ON A/C NOT FOR ALL
D. Do a Check of the Filters in the Yellow Hydraulic System
   (1) For the low pressure (return) filter (3002GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no more maintenance is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do an operational test of the Yellow hydraulic system (Ref. AMM TASK 29-13-00-710-002).
       3 If the red indicator button is out (after the operational test):
         a Push the red indicator button in to set it again.
         b Replace the filter element (Ref. AMM TASK 29-13-44-610-001).
       4 If the red indicator button is not out (after the operational test):
         a Do a check the clogging indicator again after the next flight, if the red indicator button is out:
         b Do a check the red indicator button again in less than five FC, if the red indicator button is out:
   (2) For the high pressure (delivery) filter (3048GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no more maintenance is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do an operational test of the Yellow hydraulic system (Ref. AMM TASK 29-13-00-710-002).
       3 If the red indicator button is out (after the operational test):
         a Push the red indicator button in to set it again.
         b Replace the filter element (Ref. AMM TASK 29-13-45-610-001).
       4 If the red indicator is not out (after the operational test):
         a Do a check the clogging indicator again after the next flight, if the red indicator button is out:
         b Do a check the red indicator button again in less than 5 FC, if the red indicator button is out:
   (3) For the EDP case drain filter (3084GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no more maintenance is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do an operational test of the Yellow hydraulic system (Ref. AMM TASK 29-13-00-710-002).
       3 If the red indicator button is out (after the operational test):
         a Push the red indicator button in to set it again.
         b Replace the cartridge of the related case drain filter (Ref. AMM TASK 29-13-43-610-802).
         c Examine the removed cartridge for contamination:
       4 If the red indicator button is not out (after the operational test):
         a Do a check the clogging indicator again after the next flight, if the red indicator button is out:
         b Examine the removed cartridge for contamination:
Subtask 29-10-00-210-062-D ** ON A/C NOT FOR ALL
D. Do a Check of the Filters in the Yellow Hydraulic System
   (1) For the low pressure (return) filter (3002GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no more maintenance is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do an operational test of the Yellow hydraulic system (Ref. AMM TASK 29-13-00-710-002).
       3 If the red indicator button is out (after the operational test):
         a Push the red indicator button in to set it again.
         b Replace the filter element (Ref. AMM TASK 29-13-44-610-001).
       4 If the red indicator button is not out (after the operational test):
         a Do a check the clogging indicator again after the next flight, if the red indicator button is out:
         b Do a check the red indicator button again in less than five FC, if the red indicator button is out:
   (2) For the high pressure (delivery) filter (3048GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no more maintenance is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do an operational test of the Yellow hydraulic system (Ref. AMM TASK 29-13-00-710-002).
       3 If the red indicator button is out (after the operational test):
         a Push the red indicator button in to set it again.
         b Replace the filter element (Ref. AMM TASK 29-13-45-610-001).
       4 If the red indicator is not out (after the operational test):
         a Do a check the clogging indicator again after the next flight, if the red indicator button is out:
         b Do a check the red indicator button again in less than 5 FC, if the red indicator button is out:
   (3) For the EDP case drain filter (3084GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no more maintenance is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do an operational test of the Yellow hydraulic system (Ref. AMM TASK 29-13-00-710-002).
       3 If the red indicator button is out (after the operational test):
         a Push the red indicator button in to set it again.
         b Replace the cartridge of the related case drain filter (Ref. AMM TASK 29-13-43-610-041).
         c Examine the removed cartridge for contamination:
       4 If the red indicator button is not out (after the operational test):
         a Do a check the clogging indicator again after the next flight, if the red indicator button is out:
         b Examine the removed cartridge for contamination:
Subtask 29-10-00-210-063-A
E. Do a Check of the Filters in the Reservoir Pressurization Unit (1360GM) and the Reservoir Filling System
   (1) For the reservoir pressurization filter:
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no further action is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do a functional test of the pressurizing system for the reservoirs (Ref. AMM TASK 29-14-00-720-001).
       3 If the red indicator button is out (after the functional test):
         a Push the red indicator button in to set it again.
         b Replace the filter element (Ref. AMM TASK 29-14-41-610-002).
       4 If the red indicator button is not out (after the functional test):
         a Check the clogging indicator again after the next flight, if the red indicator button is out:
         b Check the red indicator button again in less than 5 FC, if the red indicator button is out:
   (2) For the water separator filter:
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no further action is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do a functional test of the pressurizing system for the reservoirs (Ref. AMM TASK 29-14-00-720-001).
       3 If the red indicator button is out (after the functional test):
         a Push the red indicator button in to set it again.
         b Replace the filter element (Ref. AMM TASK 29-14-42-000-002) and (Ref. AMM TASK 29-14-42-400-002).
       4 If the red indicator button is not out (after the functional test):
         a Check the clogging indicator again after the next flight, if the red indicator button is out:
         b Check the red indicator button again in less than 5 FC, if the red indicator button is out:
   (3) For the (ground service) filter (1132GM):
     (a) Make sure that the red indicator button is not out.
       1 If the red indicator button is not out, then no further action is necessary.
       2 If the red indicator button is out:
         a Push the red indicator button in to set it again.
         b Do a test of the filling system (Ref. AMM TASK 29-16-11-610-001).
       3 If the red indicator button is out (after the test):
         a Push the red indicator button in to set it again.
         b Replace the filter element (Ref. AMM TASK 29-16-11-610-001).
       4 If the red indicator button is not out (after the test), then no further action is necessary.
       5 After the aircraft goes back to the main base, do a new check of the clogging indicator.
         a If the red indicator button is out:
5. Close-up
Subtask 29-10-00-410-075-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the main door of the main gear (Ref. AMM TASK 32-12-00-410-001).
   (3) Close fan cowl doors 437AL 438AR 447AL 448AR (Ref. AMM D/O 71-13-00-41).
   (4) Close access doors 195BB 196BB 197CB 197FB.
Subtask 29-10-00-410-075-B ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the main door of the main gear (Ref. AMM TASK 32-12-00-410-001).
   (3) Close fan cowl doors 437AL 438AR 447AL 448AR (Ref. AMM TASK 71-13-00-410-040).
   (4) Close access doors 195BB 196BB 197CB 197FB.
Subtask 29-10-00-410-075-C ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the main door of the main gear (Ref. AMM TASK 32-12-00-410-001).
   (3) Close fan cowl doors 437AL 438AR 447AL 448AR (Ref. AMM TASK 71-13-00-410-802).
   (4) Close access doors 195BB 196BB 197CB 197FB.
Subtask 29-10-00-410-075-D ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the main door of the main gear (Ref. AMM TASK 32-12-00-410-001).
   (3) Close fan cowl doors 437AL 438AR 447AL 448AR (Ref. AMM TASK 71-13-00-410-040).
   (4) Close access doors 195BB 196BB 197CB 197FB.
[Rev.10 from 2021] 2026.04.01 04:08:48 UTC