Operational Test of the Yellow Hydraulic System
TASK 29-13-00-710-002-A
Operational Test of the Yellow Hydraulic System
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 29-13-00-865-050-A
Subtask 29-13-00-710-051-A ** ON A/C NOT FOR ALL
Subtask 29-13-00-710-051-B ** ON A/C NOT FOR ALL
Subtask 29-13-00-710-051-C ** ON A/C NOT FOR ALL
Subtask 29-13-00-710-051-D ** ON A/C NOT FOR ALL
5. Close-up
Subtask 29-13-00-860-053-A
[Rev.10 from 2021]
2026.04.01 07:50:46 UTC
Operational Test of the Yellow Hydraulic System
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-12-29-611-001-A | Fill the Hydraulic Fluid Reservoir with a Hand Pump |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 29-14-00-614-002-A | Pressurization of the Hydraulic Reservoirs through the Ground Connector |
| TASK 29-14-00-614-002-A-01 | Pressurization of the Hydraulic Reservoirs with the Auxiliary Power Unit (APU) |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
| TASK 71-00-00-710-001-A | Dry Motoring Check |
| TASK 71-00-00-710-001-B | Dry Motoring Check |
| TASK 71-00-00-710-045-A | Test No.1 : Dry Motor Leak Check |
| TASK 71-00-00-860-817-A | Motor the Engine (Dry Method) |
Subtask 29-13-00-865-050-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 29-13-00-860-052-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | HYDRAULIC/SOL VALVES/G/Y/PTU | 1801GL | N34 |
| 121VU | HYDRAULIC/Y HYD/PUMP ENG2/MONG | 3700GD | Q37 |
| 121VU | HYDRAULIC/Y HYD/PUMP ENG2/CTL | 3701GD | Q36 |
B. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
(3) On the ECAM control panel on the center pedestal, press the HYD pushbutton switch P/BSW. Make sure that the HYD page is shown on the lower Display Unit (DU) of the ECAM.
(4) Make sure that the ECAM does not show any of these conditions;
(6) If necessary, add fluid to the reservoir (Ref. AMM TASK 12-12-29-611-001).
(7) On the overhead panel 40VU, press the PTU/AUTO P/BSW (the OFF light comes on).
(8) On the overhead panel 40VU, make sure that the YELLOW/ENG 2 PUMP P/BSW is set to on. (FAULT and OFF lights are out).
4. Procedure(1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
(3) On the ECAM control panel on the center pedestal, press the HYD pushbutton switch P/BSW. Make sure that the HYD page is shown on the lower Display Unit (DU) of the ECAM.
(4) Make sure that the ECAM does not show any of these conditions;
- low air pressure in the Yellow reservoir,
- low fluid level in the Yellow reservoir.
(6) If necessary, add fluid to the reservoir (Ref. AMM TASK 12-12-29-611-001).
(7) On the overhead panel 40VU, press the PTU/AUTO P/BSW (the OFF light comes on).
(8) On the overhead panel 40VU, make sure that the YELLOW/ENG 2 PUMP P/BSW is set to on. (FAULT and OFF lights are out).
Subtask 29-13-00-710-051-A ** ON A/C NOT FOR ALL
WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
CAUTION:
DO NOT START OR DRY MOTOR THE ENGINES WITH A HYDRAULIC GROUND POWER SUPPLY CONNECTED TO THE AIRCRAFT. IF YOU DO, YOU CAN CAUSE DAMAGE TO THE ENGINE PUMPS.
A. Operational Test of the Yellow Hydraulic System | ACTION | RESULT |
|---|---|
| 1.Dry-motor the right (No. 2) engine (Ref. AMM TASK 71-00-00-710-001). |
|
2.On the overhead panel 40VU:
| On the overhead panel 40VU:
|
| | On the ECAM lower DU:
|
On the overhead panel 40VU:
| On the overhead panel 40VU:
|
| | On the ECAM lower DU:
|
| 3.Stop the dry-motoring of the right (No. 2) engine (Ref. AMM TASK 71-00-00-710-001). | On the ECAM lower DU:
|
WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
CAUTION:
DO NOT START OR DRY MOTOR THE ENGINES WITH A HYDRAULIC GROUND POWER SUPPLY CONNECTED TO THE AIRCRAFT. IF YOU DO, YOU CAN CAUSE DAMAGE TO THE ENGINE PUMPS.
A. Operational Test of the Yellow Hydraulic System | ACTION | RESULT |
|---|---|
| 1.Dry-motor the right (No. 2) engine (Ref. AMM TASK 71-00-00-710-001). |
|
2.On the overhead panel 40VU:
| On the overhead panel 40VU:
|
| | On the ECAM lower DU:
|
On the overhead panel 40VU:
| On the overhead panel 40VU:
|
| | On the ECAM lower DU:
|
| 3.Stop the dry-motoring of the right (No. 2) engine (Ref. AMM TASK 71-00-00-710-001). | On the ECAM lower DU:
|
WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
CAUTION:
DO NOT START OR DRY MOTOR THE ENGINES WITH A HYDRAULIC GROUND POWER SUPPLY CONNECTED TO THE AIRCRAFT. IF YOU DO, YOU CAN CAUSE DAMAGE TO THE ENGINE PUMPS.
A. Operational Test of the Yellow Hydraulic System | ACTION | RESULT |
|---|---|
| 1.Dry-motor the right (No. 2) engine (Ref. AMM TASK 71-00-00-710-045). |
|
2.On the overhead panel 40VU:
| On the overhead panel 40VU:
|
| | On the ECAM lower DU:
|
On the overhead panel 40VU:
| On the overhead panel 40VU:
|
| | On the ECAM lower DU:
|
| 3.Stop the dry-motoring of the right (No. 2) engine (Ref. AMM TASK 71-00-00-710-045). | On the ECAM lower DU:
|
WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
CAUTION:
DO NOT START OR DRY MOTOR THE ENGINES WITH A HYDRAULIC GROUND POWER SUPPLY CONNECTED TO THE AIRCRAFT. IF YOU DO, YOU CAN CAUSE DAMAGE TO THE ENGINE PUMPS.
A. Operational Test of the Yellow Hydraulic System | ACTION | RESULT |
|---|---|
| 1.Dry-motor the right (No. 2) engine (Ref. AMM TASK 71-00-00-860-817). |
|
2.On the overhead panel 40VU:
| On the overhead panel 40VU:
|
| | On the ECAM lower DU:
|
On the overhead panel 40VU:
| On the overhead panel 40VU:
|
| | On the ECAM lower DU:
|
| 3.Stop the dry-motoring of the right (No. 2) engine (Ref. AMM TASK 71-00-00-860-817). | On the ECAM lower DU:
|
Subtask 29-13-00-860-053-A
A. Put the aircraft back to the serviceable condition.
(1) On the overhead panel 40VU, press and release the PTU/AUTO P/BSW, (the OFF light goes out).
(2) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(3) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
(1) On the overhead panel 40VU, press and release the PTU/AUTO P/BSW, (the OFF light goes out).
(2) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(3) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).