W DOC AIRBUS | AMM A320F

EIS Stop Procedure


TASK 31-60-00-860-002-A
EIS Stop Procedure


ZONE: 210
1. Reason for the Job
To have the six Display Units (DU) in standby condition (they are energized but no image is shown).
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
3. Job Set-up
Subtask 31-60-00-860-053-A
A. Aircraft Maintenance Configuration
   (1) On the center pedestal, on the SWITCHING panel 8VU, set the selector switches to NORM.

4. Procedure
Subtask 31-60-00-860-052-A
A. Set the six Display Units (DU) to the standby position:
ACTION
RESULT
1.On the CAPT lighting/LOUD SPEAKER control panel 301VU:

  • turn the PFD potentiometer counterclockwise to the minimum standby position but not to OFF.
  • the CAPT Primary Flight Display (PFD) is black, or at least very dimmed.
  • turn the ND potentiometer counterclockwise to the standby position.
  • the CAPT Navigation Display (ND) is black, or at least very dimmed.
2.On the center pedestal, on the ECAM control panel:

  • turn the UPPER DISPLAY potentiometer counterclockwise to the standby position.
  • the upper ECAM DU is black, or at least very dimmed.
  • turn the LOWER DISPLAY potentiometer counterclockwise to the standby position.
  • the lower ECAM DU is black, or at least very dimmed
3.On the F/O lighting/LOUD SPEAKER control panel 500VU:

  • turn the ND potentiometer counterclockwise to the standby position.
  • the F/O ND is black, or at least very dimmed.
  • turn the PFD potentiometer counterclockwise to the standby position.
  • the F/O PFD is black, or at least very dimmed.
[Rev.10 from 2021] 2026.04.01 00:37:38 UTC