EIS Stop Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
To have the six Display Units (DU) in standby condition (they are energized but no image is shown).
2. Job Set-up Information
A. Work Zones and Access Panels
3. Job Set-up
Subtask 31-60-00-860-053-A
Subtask 31-60-00-860-052-A
[Rev.10 from 2021]
2026.04.01 00:37:38 UTC
EIS Stop Procedure
ZONE: 210
1. Reason for the JobTo have the six Display Units (DU) in standby condition (they are energized but no image is shown).
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
Subtask 31-60-00-860-053-A
A. Aircraft Maintenance Configuration
(1) On the center pedestal, on the SWITCHING panel 8VU, set the selector switches to NORM.
4. Procedure(1) On the center pedestal, on the SWITCHING panel 8VU, set the selector switches to NORM.
Subtask 31-60-00-860-052-A
A. Set the six Display Units (DU) to the standby position:
| ACTION | RESULT |
|---|---|
| 1.On the CAPT lighting/LOUD SPEAKER control panel 301VU: | |
|
|
|
|
| 2.On the center pedestal, on the ECAM control panel: | |
|
|
|
|
| 3.On the F/O lighting/LOUD SPEAKER control panel 500VU: | |
|
|
|
|