W DOC AIRBUS | AMM A320F

Pressurization of the Hydraulic Reservoirs through the Ground Connector


TASK 29-14-00-614-002-A
Pressurization of the Hydraulic Reservoirs through the Ground Connector


WARNING: MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
ZONE: 195
FIN: 1000GQ
FIN: 2000GQ
FIN: 3000GQ
1. Reason for the Job
To pressurize the hydraulic reservoirs through the ground connector.
NOTE: The reservoirs are pressurized through the air pressurization manifold, thus they are pressurized at the same time.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
Torque wrench: range to between 1.9 and 1.7 m.daN (14.01 and 12.54 lbf.ft ) T
97A29102035000
1
CONNECTOR-PRESSURIZING,HYDRAULIC TANK
98D29003501000
1
FILL UNIT-AIR PRESSURIZING TOOL, HYDRAULIC RESERVOIR
98D29003501003
1
FILL UNIT - AIR
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
195
HYDRAULIC COMPT AND FAIRINGS
195BB, 196BB, 197CB, 197EB, 197FB, 198CB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 29-10-00-200-002-A
Check Reservoir Air Pressure on Reservoir Gauge
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
TASK 32-12-00-410-001-A
Close the Main Gear Doors after Access
3. Job Set-up
Subtask 29-14-00-865-060-A
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUHYD/HYD PWR/B WARN/& CTL2702GJC12
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN30
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN31
** ON A/C ALL
123VUB HYD/ELEC PUMP2701GJAB09
123VUY HYD/ELEC/PUMP3802GXAB06
123VUY HYD/ELEC/ELEC PUMP/NORM3801GXAB03
Subtask 29-14-00-010-051-A
B. Get Access
   (1) Open the applicable access door:
For the ground service panel of the Green hydraulic system
For the ground service panel of the Blue hydraulic system
For the ground service panel of the Yellow hydraulic system
   (2) Open the access doors 195BB, 196BB and 197FB.
   (3) Open one of the main doors of the main gear (Ref. AMM TASK 32-12-00-010-001).
Subtask 29-14-00-869-051-A
C. Make sure that the applicable reservoir depressurization valve (1087GM, 2087GM or 3087GM) is closed.
4. Procedure
Subtask 29-14-00-614-050-B
A. Pressurizing
   (1) Remove the cap from the ground connector.
   (2) Connect the 98D29003501000 FILL UNIT-AIR PRESSURIZING TOOL, HYDRAULIC RESERVOIR or 98D29003501003 FILL UNIT - AIR to the ground connector.
NOTE: If the pressurizing tool is not available, you can use an alternative supply of air. The supply must have a pressure of 5 bar (73 psi) and it must have a filter of 5 microns or better.
As alternative to the air source, you can use the nitrogen source with 97A29102035000 CONNECTOR-PRESSURIZING,HYDRAULIC TANK.
   (3) Turn the nut counterclockwise to open the ground connector.
   (4) Fill the reservoir with air until 50 psi (3 bar) is shown on the reservoir pressure gages 1383GM, 2383GM and 3383GM.
   (5) Turn the nut clockwise to close the ground connector.
   (6) TORQUE the nut to between 1.9 and 1.7 m.daN (14.01 and 12.54 lbf.ft ) T.
NOTE: Obey the limits (Ref. AMM TASK 29-10-00-200-002), if there is a decrease of the air pressure in the reservoirs.
5. Close-up
Subtask 29-14-00-860-055-A
A. Put the system back to the serviceable condition.
   (1) Remove the pressurizing tool.
   (2) Install the cap on the ground connector.
Subtask 29-14-00-410-051-A
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the access door 195BB, 196BB and 197FB.
   (3) Close the applicable access panels (doors):
For the ground service panel of the Green hydraulic system
For the ground service panel of the Blue hydraulic system
For the ground service panel of the Yellow hydraulic system
   (4) Close the main door of the main gear (Ref. AMM TASK 32-12-00-410-001).
Subtask 29-14-00-865-051-A
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUHYD/HYD PWR/B WARN/& CTL2702GJC12
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN30
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN31
** ON A/C ALL
123VUB HYD/ELEC PUMP2701GJAB09
123VUY HYD/ELEC/PUMP3802GXAB06
123VUY HYD/ELEC/ELEC PUMP/NORM3801GXAB03
[Rev.10 from 2021] 2026.04.01 00:24:07 UTC