Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
Self explanatory
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 24-41-00-860-051-A
Subtask 24-41-00-861-052-A
[Rev.10 from 2021]
2026.03.31 23:24:06 UTC
Energize the Aircraft Electrical Circuits from the APU
WARNING:
MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-31-31-660-001-A | Cold Weather Maintenance - Indicating/Recording systems and Navigation |
| TASK 12-34-24-869-002-A | Aircraft Grounding (Earthing) for the Maintenance Operations |
| TASK 12-34-24-869-002-A-01 | Aircraft Grounding (Earthing) during Transit, Turnaround or Overnight Stop |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 49-00-00-860-005-A | APU Start by External Power |
| TASK 49-00-00-860-005-A-01 | APU Start by Batteries |
| TASK 49-00-00-860-008-A | APU Start by External Power |
| TASK 49-00-00-860-008-A-01 | APU Start by Batteries |
Subtask 24-41-00-860-051-A
A. Aircraft Maintenance Configuration
4. ProcedureNOTE: In the avionics compartment, if the temperature is below -15 deg.C (5.00 deg.F), do the cold-weather maintenance procedure (Ref. AMM TASK 12-31-31-660-001).
(1) Ground (Earth) the aircraft if necessary (Ref. AMM TASK 12-34-24-869-002): - For grounding (earthing) you must obey the local area regulations.
- the GEN1, GEN2, APU GEN, BUS TIE and AC ESS FEED pushbutton switches are pushed,
Subtask 24-41-00-861-052-A
A. Energize the aircraft electrical circuit from the APU.
(1) Start the APU:
(Ref. AMM TASK 31-60-00-860-001).
(3) On the ECAM control panel, push the ELEC key (on the lower ECAM DU, the ELEC page comes into view).
(4) Make sure that the APU energizes the aircraft electrical circuit correctly.
(5) On the VENTILATION section of the panel 22VU:
(1) Start the APU:
- GTCP 36-300 (Ref. AMM D/O 49-00-00-86)
or - APS 3200 (Ref. AMM TASK 49-00-00-860-005)
or - 131-9(A) (Ref. AMM TASK 49-00-00-860-008).
(Ref. AMM TASK 31-60-00-860-001).
(3) On the ECAM control panel, push the ELEC key (on the lower ECAM DU, the ELEC page comes into view).
(4) Make sure that the APU energizes the aircraft electrical circuit correctly.
(5) On the VENTILATION section of the panel 22VU:
- make sure that the FAULT legends of the BLOWER and EXTRACT pushbutton switches are off.
NOTE: This is an indication of the correct operation of the avionics equipment ventilation.