Installation of the Green Engine Pump
TASK 29-11-51-400-040-A
Installation of the Green Engine Pump
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 29-11-51-860-053-A ** ON A/C NOT FOR ALL
Subtask 29-11-51-640-050-B ** ON A/C NOT FOR ALL
Subtask 29-11-51-860-072-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:18:07 UTC
Installation of the Green Engine Pump
WARNING:
OBEY THE HYDRAULIC SAFETY PROCEDURES.
WARNING:
DO NOT TOUCH THE HYDRAULIC SYSTEM COMPONENTS FOR A SHORT TIME AFTER THE ENGINE IS SHUTDOWN. THE ENGINE COMPONENTS STAY HOT FOR SOME TIME AND CAN CAUSE INJURY.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION:
DO NOT LET HYDRAULIC FLUID FALL ON THE ENGINE. UNWANTED HYDRAULIC FLUID MUST BE REMOVED IMMEDIATELY WITH A CLEAN LINT FREE CLOTH. THE FLUID CAN CAUSE DAMAGE TO THE SURFACE PROTECTION AND TO SOME PARTS.
FIN: 1030GK ** ON A/C NOT FOR ALL
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.02ABA1) | Phosphate Ester Hydraulic Fluid-General Power - - |
| (Material No.03ABA1) | Synthetic base Lubricating Oil-Turbine Engine - - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 195BB, 197CB, 437AL |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 50 | PACKING | AIPC 29-11-51-01-040 |
| 25 | NUT | AIPC 29-11-51-02-010 |
| 30 | GASKET | AIPC 29-11-51-02-020 |
| 45 | PACKING | AIPC 29-11-51-02-040 |
| 40 | PACKING | AIPC 29-11-51-02-060 |
| 35 | BACK-UP RING | AIPC 29-11-51-02-071 |
| 55 | PACKING | AIPC 29-11-51-02-073 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 29-10-00-720-001-A | Functional Check of Hydraulic Fire Shut-Off Valves |
| TASK 29-10-00-864-001-A | Depressurize the Green Hydraulic System |
| TASK 29-11-51-860-040-A | Hydraulic Maintenance Procedure after an Engine Installation (with Engine Pump Installed) or after an Engine Pump Installation |
| TASK 29-14-00-614-001-A | Depressurization of the Hydraulic Reservoirs |
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
Subtask 29-11-51-860-053-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that the Green hydraulic system is depressurized (Ref. AMM TASK 29-10-00-864-001).
(3) Make sure that the Green hydraulic reservoir is depressurized (Ref. AMM TASK 29-14-00-614-001).
(4) Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to pressurize the Green hydraulic system:
(6) Make sure that the left fan cowl door 437AL is open (Ref. AMM TASK 71-13-00-010-040).
(7) On the ECAM control panel:
Subtask 29-11-51-941-055-A ** ON A/C NOT FOR ALL (1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that the Green hydraulic system is depressurized (Ref. AMM TASK 29-10-00-864-001).
(3) Make sure that the Green hydraulic reservoir is depressurized (Ref. AMM TASK 29-14-00-614-001).
(4) Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to pressurize the Green hydraulic system:
- on the ground service panel 197CB.
(6) Make sure that the left fan cowl door 437AL is open (Ref. AMM TASK 71-13-00-010-040).
(7) On the ECAM control panel:
- Make sure that the HYD key is pushed.
- Make sure that the ENG1/FIRE pushbutton is released.
- Make sure that the fire shut-off valve (1046GK) is closed.
B. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(3) Make sure that the WARNING NOTICE(S) is in position to tell persons not to pressurize the Green hydraulic system:
Subtask 29-11-51-865-054-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
- make sure that WARNING NOTICE(S) is (are) in position to tell persons not to start the engine.
(3) Make sure that the WARNING NOTICE(S) is in position to tell persons not to pressurize the Green hydraulic system:
- In the cockpit, on the HYD section of the panel 40VU.
- Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off
- Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to energize the FADEC 1(2).
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/G HYD/PUMP ENG1/CTL | 1701GK | R35 |
| 121VU | HYDRAULIC/G HYD/PUMP ENG1/MONG | 1702GK | R34 |
Subtask 29-11-51-640-050-B ** ON A/C NOT FOR ALL
A. Preparation before Installation
(3) Remove the blanking covers from the threads of the unions (10) and (15), reducer (20) and pump (5) ports.
(4) Apply Phosphate Ester Hydraulic Fluid-General Power - - (Material No.02ABA1) on the new AIPC 29-11-51-02-071 BACK-UP RING (35) and the new AIPC 29-11-51-02-060 PACKING (40), AIPC 29-11-51-02-040 PACKING (45) and AIPC 29-11-51-02-073 PACKING (55).
(5) Install the back-up ring (35) and the packing (55) on the reducer (20).
(7) TORQUE the reducer (20) to between 1450 and 1350 lbf.in (16.39 and 15.26 m.daN )
.
Subtask 29-11-51-420-054-A ** ON A/C NOT FOR ALL CAUTION:
DO NOT APPLY LUBRICANT ON POLYAMIDE-TYPE INTERNAL COUPLING- SHAFTS WHEN YOU INSTALL THE SHAFT ON THE PUMP. IF YOU APPLY LUBRICANT, DAMAGE CAN OCCUR.
(1) Apply Synthetic base Lubricating Oil-Turbine Engine - - (Material No.03ABA1) on the new AIPC 29-11-51-01-040 PACKING (50). CAUTION:
MAKE SURE THAT THE PACKING IS IN THE CORRECT LOCATION ON THE SPLINE SHAFT. IF THE PACKING IS NOT IN THE SQUARE SECTION GROOVE, THERE IS A RISK OF OIL LEAKAGE.
CAUTION:
WHEN YOU HANDLE THE COUPLING SHAFT PACKING, MAKE SURE THAT YOU DO NOT PUT IT IN CONTACT WITH THE ALKYL PHOSPHATE ESTER BASE FLUIDS USED IN THE PUMP. IF THE PACKING COMES IN CONTACT WITH THE ALKYL PHOSPHATE ESTER BASE FLUIDS, THIS WILL DECREASE ITS SERVICE LIFE TIME.
(2) Install the packing (50) in the square section groove on the input splined shaft of the pump (5). (3) Remove the blanking covers from the threads of the unions (10) and (15), reducer (20) and pump (5) ports.
(4) Apply Phosphate Ester Hydraulic Fluid-General Power - - (Material No.02ABA1) on the new AIPC 29-11-51-02-071 BACK-UP RING (35) and the new AIPC 29-11-51-02-060 PACKING (40), AIPC 29-11-51-02-040 PACKING (45) and AIPC 29-11-51-02-073 PACKING (55).
(5) Install the back-up ring (35) and the packing (55) on the reducer (20).
CAUTION:
BE CAREFUL WHEN YOU INSTALL/CONNECT PARTS ON THE PUMP TO MAKE SURE THAT THE HYDRAULIC FLUID DOES NOT FLOW OUT. THE PUMP IS FULL OF HYDRAULIC FLUID.
(6) Install the reducer (20) in the pump (5) pressure port. (7) TORQUE the reducer (20) to between 1450 and 1350 lbf.in (16.39 and 15.26 m.daN )
. B. Installation of the Union
(1) Install the AIPC 29-11-51-02-040 PACKING (45) on the union (15).
(2) Install the union (15) in the pump (5) case drain port.
(3) TORQUE the union (15) to between 290 and 270 lbf.in (3.28 and 3.05 m.daN )
.
(4) Install the AIPC 29-11-51-02-060 PACKING (40) on the union (10).
(5) Install the union (10) in the pump (5) suction port.
(6) TORQUE the union (10) to between 940 and 860 lbf.in (10.62 and 9.72 m.daN )
.
(7) Install the new AIPC 29-11-51-02-020 GASKET (30) on the mount pad.
(8) Install the new mount AIPC 29-11-51-02-010 NUT (25) loosely on the four studs in the pump mount pad.
Subtask 29-11-51-420-053-A ** ON A/C NOT FOR ALL (1) Install the AIPC 29-11-51-02-040 PACKING (45) on the union (15).
(2) Install the union (15) in the pump (5) case drain port.
(3) TORQUE the union (15) to between 290 and 270 lbf.in (3.28 and 3.05 m.daN )
. (4) Install the AIPC 29-11-51-02-060 PACKING (40) on the union (10).
(5) Install the union (10) in the pump (5) suction port.
(6) TORQUE the union (10) to between 940 and 860 lbf.in (10.62 and 9.72 m.daN )
. (7) Install the new AIPC 29-11-51-02-020 GASKET (30) on the mount pad.
(8) Install the new mount AIPC 29-11-51-02-010 NUT (25) loosely on the four studs in the pump mount pad.
C. Installation of the Green Engine Pump Vickers
(1) Put the pump (5) on the mount pad with the nuts (25) through the large end of the holes in the pump base.
(2) Turn the pump (5) counterclockwise until it touches the studs.
(3) Do a running torque check of the nuts (25) with a torque wrench.
(b) Set the torque wrench to 9.5 lbf.in (0.11 m.daN) and turn each nut in the tightening direction. The nut(s) must not turn before the set torque value.
(c) If the nut(s) turn before you get 9.5 lbf.in (0.11 m.daN) torque, replace the nut(s) and do 4.C.(3) again for each replacement nut.
(d) If the nut(s) pass the running torque check, do not remove the nut(s) from the stud(s) and do step 4.C.(4).
(4) TORQUE the nuts (25) to between 320 and 260 lbf.in (3.62 and 2.94 m.daN )
.
(5) Make sure that the blanking covers are removed from the hose couplings, the pump unions (10), (15) and the reducer (20) before installation.
(6) Connection of the case drain hose
(7) TORQUE the case drain hose coupling nut to between 245 and 215 lbf.in (2.77 and 2.43 m.daN )
.
(9) Connect the suction hose to the adapter (70).
(10) TORQUE the coupling nut of the suction hose to the adapter (70) to between 900 and 800 lbf.in (10.17 and 9.04 m.daN )
.
(11) TORQUE the coupling nut of the adapter (70) to the union (10) to between 900 and 800 lbf.in (10.17 and 9.04 m.daN )
.
(13) TORQUE the pressure hose coupling nut to between 1000 and 900 lbf.in (11.30 and 10.17 m.daN )
.
(14) Remove the blanking cap from the electrical connector (1030GKA).
(15) Connect the electrical connector (1030GKA) to the pump (35).
(a) Make sure that all the electrical connections are clean and in the correct condition.
(b) Align the master-key (largest key) on the connector with the master-key in the receptacle.
(c) Use light hand pressure and push the connector in the receptacle. Turn the coupling nut clockwise to engage the connector threads.
(d) Tighten the connection.
Subtask 29-11-51-420-065-A ** ON A/C NOT FOR ALL (1) Put the pump (5) on the mount pad with the nuts (25) through the large end of the holes in the pump base.
(2) Turn the pump (5) counterclockwise until it touches the studs.
(3) Do a running torque check of the nuts (25) with a torque wrench.
CAUTION:
DISCARD THE NUT(S) IF YOU CAN TURN THEM BY HAND WITH NO RESISTANCE.
(a) Install new nuts (25) on the studs of the mount pad and turn the nuts until resistance is felt. (b) Set the torque wrench to 9.5 lbf.in (0.11 m.daN) and turn each nut in the tightening direction. The nut(s) must not turn before the set torque value.
(c) If the nut(s) turn before you get 9.5 lbf.in (0.11 m.daN) torque, replace the nut(s) and do 4.C.(3) again for each replacement nut.
(d) If the nut(s) pass the running torque check, do not remove the nut(s) from the stud(s) and do step 4.C.(4).
(4) TORQUE the nuts (25) to between 320 and 260 lbf.in (3.62 and 2.94 m.daN )
. (5) Make sure that the blanking covers are removed from the hose couplings, the pump unions (10), (15) and the reducer (20) before installation.
(6) Connection of the case drain hose
CAUTION:
BE CAREFUL WHEN YOU INSTALL/CONNECT PARTS ON THE PUMP TO MAKE SURE THAT THE HYDRAULIC FLUID DOES NOT FLOW OUT. THE PUMP IS FULL OF HYDRAULIC FLUID.
(a) Connect the case drain hose to the union (15) in the pump (5) case drain port. (7) TORQUE the case drain hose coupling nut to between 245 and 215 lbf.in (2.77 and 2.43 m.daN )
. NOTE: Use a second WRENCH - TORQUE to hold the union (15) when you torque the case drain hose coupling nut.
(8) Connect the suction hose adapter (70) to the union (10) in the pump (5) suction port. (9) Connect the suction hose to the adapter (70).
(10) TORQUE the coupling nut of the suction hose to the adapter (70) to between 900 and 800 lbf.in (10.17 and 9.04 m.daN )
. (11) TORQUE the coupling nut of the adapter (70) to the union (10) to between 900 and 800 lbf.in (10.17 and 9.04 m.daN )
. NOTE: Use a second wrench to hold the union (10) when you torque the adapter (70) coupling nut.
(12) Connect the pressure hose to the reducer (20) in the pump (5) pressure port. (13) TORQUE the pressure hose coupling nut to between 1000 and 900 lbf.in (11.30 and 10.17 m.daN )
. (14) Remove the blanking cap from the electrical connector (1030GKA).
(15) Connect the electrical connector (1030GKA) to the pump (35).
(a) Make sure that all the electrical connections are clean and in the correct condition.
(b) Align the master-key (largest key) on the connector with the master-key in the receptacle.
(c) Use light hand pressure and push the connector in the receptacle. Turn the coupling nut clockwise to engage the connector threads.
(d) Tighten the connection.
CAUTION:
YOU MUST NOT STOP AT THE COLORED COUPLING INDICATOR LINE ON THE RECEPTACLE WHEN YOU TIGHTEN THE CONNECTOR. IF YOU STOP AT THE COLORED LINE THE CONNECTION WILL NOT BE TIGHT. THIS CAN CAUSE MECHANICAL AND/OR ELECTRICAL FAILURE.
1 With the threads correctly engaged, continue to turn the coupling nut clockwise with your hand until the connection is tight. Make sure that you cannot see the colored coupling indicator line on the receptacle when the connection is fully tight. NOTE: If you move the connector from side to side when you turn the coupling nut it will make it easier to tighten.
(e) Use PLIERS - CONNECTOR, JAW, SOFT. CAUTION:
YOU MUST NOT USE PLIERS WITH METAL JAWS TO TIGHTEN OR LOOSEN THE CONNECTOR. THE METAL JAWS WILL CAUSE DAMAGE TO THE CONNECTOR.
1 Turn the connector ring from one eighth to a quarter of a turn with PLIERS - CONNECTOR, JAW, SOFT or a WRENCH GLENAIR TG70 - STRAP to make sure that the connector is tight. Stop before the pliers or strap wrench slip on the connector ring. D. Installation of the Abex Green Engine-Pump
(1) Put the pump (5) on the mount pad with the new AIPC 29-11-51-02-010 NUT (25) through the large end of the holes in the pump (5) base.
(2) Turn the pump (5) counterclockwise until it touches the studs.
(3) Do a running torque check of the nuts (25) with the WRENCH - TORQUE:
(b) Set the torque wrench to 9.5 lbf.in (0.11 m.daN) and turn each nut in the tightening direction. The nuts must not turn before the set torque value.
(c) If the nuts turn before you get a torque of 9.5 lbf.in (0.11 m.daN), replace the nuts and do Step 4.C.(3) again. Do this step again for each nut that you replace.
(d) If the result of the running torque check is satisfactory, do not remove the nuts from the studs and do Step 4.C.(4).
(4) TORQUE the nuts (25) to between 320 and 260 lbf.in (3.62 and 2.94 m.daN )
.
(5) Make sure that the blanking covers are removed from the hose couplings, pump unions (10) and (15) and reducer (20) before installation.
(6) Connect the case drain hose as follows:
(7) TORQUE the case-drain hose coupling-nut to between 245 and 215 lbf.in (2.77 and 2.43 m.daN )
.
(9) Connect the suction hose to the adapter (70).
(10) TORQUE the coupling nut of the suction hose on the adapter (70) to between 900 and 800 lbf.in (10.17 and 9.04 m.daN )
.
(11) TORQUE the coupling nut of the adapter (70) on the union (10) to between 900 and 800 lbf.in (10.17 and 9.04 m.daN )
.
(13) TORQUE the pressure hose coupling-nut to between 945 and 855 lbf.in (10.68 and 9.66 m.daN )
.
(15) Connect the electrical connector (1030GKA) to the pump (35).
(a) Make sure that the electrical connectors are clean and in the correct condition.
(b) Align the master-key (largest key) on the connector with the master-key in the receptacle.
(c) Use light hand pressure and push the connector in the receptacle. Turn the coupling nut clockwise to engage the connector threads.
(d) Tighten the connection as follows:
1 With the threads correctly engaged, continue to turn the coupling nut clockwise with your hand until the connection is tight.
1 Turn the connector ring from one eighth to a quarter of a turn with the PLIERS - CONNECTOR, JAW, SOFT or WRENCH GLENAIR TG70 - STRAP.
2 Make sure that the connector is tight. Stop before the PLIERS - CONNECTOR, JAW, SOFT or WRENCH GLENAIR TG70 - STRAP wrench slips on the connector ring.
Subtask 29-11-51-865-055-A ** ON A/C NOT FOR ALL (1) Put the pump (5) on the mount pad with the new AIPC 29-11-51-02-010 NUT (25) through the large end of the holes in the pump (5) base.
(2) Turn the pump (5) counterclockwise until it touches the studs.
(3) Do a running torque check of the nuts (25) with the WRENCH - TORQUE:
CAUTION:
DISCARD THE NUT(S) IF YOU CAN TURN THEM BY HAND WITH NO RESISTANCE.
(a) Install the nuts (25) on the studs of the mount pad and turn the nuts (25) until you fill resistance. (b) Set the torque wrench to 9.5 lbf.in (0.11 m.daN) and turn each nut in the tightening direction. The nuts must not turn before the set torque value.
(c) If the nuts turn before you get a torque of 9.5 lbf.in (0.11 m.daN), replace the nuts and do Step 4.C.(3) again. Do this step again for each nut that you replace.
(d) If the result of the running torque check is satisfactory, do not remove the nuts from the studs and do Step 4.C.(4).
(4) TORQUE the nuts (25) to between 320 and 260 lbf.in (3.62 and 2.94 m.daN )
. (5) Make sure that the blanking covers are removed from the hose couplings, pump unions (10) and (15) and reducer (20) before installation.
(6) Connect the case drain hose as follows:
CAUTION:
BE CAREFUL WHEN YOU INSTALL/CONNECT PARTS ON THE PUMP TO MAKE SURE THAT THE HYDRAULIC FLUID DOES NOT FLOW OUT. THE PUMP IS FULL OF HYDRAULIC FLUID.
(a) Connect the case drain hose to the union (15) in the pump (5) case drain port. (7) TORQUE the case-drain hose coupling-nut to between 245 and 215 lbf.in (2.77 and 2.43 m.daN )
. NOTE: You can use a second WRENCH - TORQUE to hold the union (15) when you torque the case-drain hose coupling-nut.
(8) Connect the suction hose adapter (70) to the union (10) in the pump (5) suction port. (9) Connect the suction hose to the adapter (70).
(10) TORQUE the coupling nut of the suction hose on the adapter (70) to between 900 and 800 lbf.in (10.17 and 9.04 m.daN )
. (11) TORQUE the coupling nut of the adapter (70) on the union (10) to between 900 and 800 lbf.in (10.17 and 9.04 m.daN )
. NOTE: You can use a second WRENCH - TORQUE to hold the union (10) when you torque the adapter (70) coupling nut.
(12) Connect the pressure hose to the reducer (20) in the pump (5) pressure port. (13) TORQUE the pressure hose coupling-nut to between 945 and 855 lbf.in (10.68 and 9.66 m.daN )
. NOTE: You can use a second WRENCH - TORQUE to hold the reducer (20) when you torque the pressure hose coupling-nut.
(14) Remove the blanking cap from the electrical connector (1030GKA). (15) Connect the electrical connector (1030GKA) to the pump (35).
(a) Make sure that the electrical connectors are clean and in the correct condition.
(b) Align the master-key (largest key) on the connector with the master-key in the receptacle.
(c) Use light hand pressure and push the connector in the receptacle. Turn the coupling nut clockwise to engage the connector threads.
(d) Tighten the connection as follows:
1 With the threads correctly engaged, continue to turn the coupling nut clockwise with your hand until the connection is tight.
CAUTION:
YOU MUST NOT STOP AT THE COLORED COUPLING INDICATOR LINE ON THE RECEPTACLE WHEN YOU TIGHTEN THE CONNECTOR. IF YOU STOP AT THE COLORED LINE THE CONNECTION WILL NOT BE TIGHT. THIS CAN CAUSE MECHANICAL AND/OR ELECTRICAL FAILURE.
2 Make sure that you cannot see the color indicator line of the coupling on the receptacle when the connection is fully tight.NOTE: If you move the connector from side to side when you turn the coupling nut, it will make it easier to tighten it.
(e) Use the PLIERS - CONNECTOR, JAW, SOFT as follows: 1 Turn the connector ring from one eighth to a quarter of a turn with the PLIERS - CONNECTOR, JAW, SOFT or WRENCH GLENAIR TG70 - STRAP.
2 Make sure that the connector is tight. Stop before the PLIERS - CONNECTOR, JAW, SOFT or WRENCH GLENAIR TG70 - STRAP wrench slips on the connector ring.
E. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 29-11-51-860-060-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/G HYD/PUMP ENG1/CTL | 1701GK | R35 |
| 121VU | HYDRAULIC/G HYD/PUMP ENG1/MONG | 1702GK | R34 |
F. Do the hydraulic maintenance procedure after an engine pump installation (Ref. AMM TASK 29-11-51-860-040).
5. Close-upSubtask 29-11-51-860-072-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) On the ECAM control panel, push the HYD key:
Subtask 29-11-51-942-051-A ** ON A/C NOT FOR ALL (1) On the ECAM control panel, push the HYD key:
- On the SD, the HYD page comes into view.
- Push the ENG1/FIRE pushbutton switch.
- Make sure that the fire shut-off valve (1046GK) is opened.
B. Remove the Safety Precautions
(1) Remove the WARNING NOTICE(S).
(2) Remove the CONTAINER 5 L (1.32 USGAL).
(3) Make sure that the work area is clean and clear of tools and other items.
Subtask 29-11-51-410-051-A ** ON A/C NOT FOR ALL Subtask 29-11-51-862-050-A ** ON A/C NOT FOR ALL (1) Remove the WARNING NOTICE(S).
(2) Remove the CONTAINER 5 L (1.32 USGAL).
(3) Make sure that the work area is clean and clear of tools and other items.
Green Engine Pump (Vickers)