22-66 FLIGHT AUGMENTATION COMPUTER (FAC)
- PB.201 FLIGHT AUGMENTATION COMPUTER (FAC) - FAULT ISOLATION PROCEDURES
-
22-66-00-810-801-A
[8]
Failure of the FAC 1 -
22-66-00-810-802-A
[8]
Failure of the FAC 2 -
22-66-00-810-803-A
[8]
Loss of the FAC 1 GENERAL Bus -
22-66-00-810-804-A
[8]
Loss of the FAC 2 GENERAL Bus -
22-66-00-810-805-A
[8]
Loss of the FAC 1 Bus Feedback -
22-66-00-810-806-A
[8]
Loss of the FAC 2 Bus Feedback -
22-66-00-810-807-A
[8]
Loss of the FAC 1 HLTY MON OWN Discrete Signal -
22-66-00-810-808-A
[8]
Loss of the FAC 1 HLTY MON OPP Discrete Signal -
22-66-00-810-809-A
[8]
Loss of the FAC 2 HLTY MON OPP Discrete Signal -
22-66-00-810-810-A
[8]
Loss of the FAC 2 HLTY MON OWN Discrete Signal -
22-66-00-810-811-A
[8]
Loss of the FAC 1 HLTY COM OPP Discrete Signal -
22-66-00-810-812-A
[8]
Loss of the FAC 2 HLTY COM OPP Discrete Signal -
22-66-00-810-813-A
[8]
Loss of the Reception of the FAC 1 GENERAL Bus by the FAC 2 -
22-66-00-810-814-A
[8]
Loss of the Reception of the FAC 2 GENERAL Bus by the FAC 1 -
22-66-00-810-815-A
[8]
Loss of the Rudder Trim Change-Over between the FAC 2 and the FAC 1 -
22-66-00-810-816-A
[8]
Loss of the Rudder Trim Change-Over between the FAC 1 and the FAC 2 -
22-66-00-810-817-A
[8]
Loss of the Rudder Travel-Limiting Change-Over between the FAC 2 and the FAC 1 -
22-66-00-810-818-A
[8]
Loss of the Rudder Travel-Limiting Change-Over between the FAC 1 and the FAC 2 -
22-66-00-810-819-A
[8]
Loss of the Yaw Damper Change-Over between the FAC 2 and the FAC 1 -
22-66-00-810-820-A
[8]
Loss of the Yaw Damper Change-Over between the FAC 1 and the FAC 2 -
22-66-00-810-821-A
[8]
Loss of the Reception of the AP 1 ENGD Discrete Signal by the FAC 1 -
22-66-00-810-822-A
[8]
Loss of the Reception of the AP2 ENGD Discrete Signal by the FAC 1 -
22-66-00-810-823-A
[8]
Loss of the Reception of the AP1 ENGD Discrete Signal by the FAC 2 -
22-66-00-810-824-A
[8]
Loss of the Reception of the AP2 ENGD Discrete Signal by the FAC 2 -
22-66-00-810-825-A
[8]
Loss of the Reception of the FMGC1 OWN B Bus by the FAC 1 -
22-66-00-810-826-A
[8]
Loss of the Reception of the FMGC1 OWN B Bus by the FAC 2 -
22-66-00-810-827-A
[8]
Loss of the Reception of the FMGC2 OWN B Bus by the FAC 1 -
22-66-00-810-828-A
[8]
Loss of the Reception of the FMGC2 OWN B Bus by the FAC 2 -
22-66-00-810-829-A
[8]
Loss of the Parity Pin Program on the FAC 1 -
22-66-00-810-830-A
[8]
Loss of the Parity Pin Program on the FAC 2 -
22-66-00-810-833-A
[8]
Loss of the Reception of the LGCIU 1 Bus by the FAC 1 -
22-66-00-810-834-A
[8]
Loss of the Reception of the LGCIU 2 Bus by the FAC 2 -
22-66-00-810-835-A
[8]
Loss of the Data from the ADIRUs to the AFS -
22-66-00-810-836-A
[8]
FAC 1 FAULT Legend Comes on without ECAM Warning -
22-66-00-810-837-A
[8]
FAC 2 FAULT Legend Comes on without ECAM Warning -
22-66-00-810-838-A
[8]
FAC 1 FAULT Legend does not Come on with ECAM Warning -
22-66-00-810-839-A
[8]
FAC 2 FAULT Legend does not Come on with ECAM Warning -
22-66-00-810-840-A
[8]
FAC 1 OFF Legend does not Come on when the FAC 1 Function Disengages -
22-66-00-810-841-A
[8]
FAC 2 OFF Legend does not Come on when the FAC 2 Function Disengages -
22-66-00-810-842-A
[8]
Loss of the Reception of the ELAC OWN Bus by the FAC 1 MON or the FAC 1 COM -
22-66-00-810-843-A
[8]
Loss of the Reception of the ELAC OPP Bus by the FAC 1 MON or the FAC 1 COM -
22-66-00-810-844-A
[8]
Loss of the Reception of the ELAC OWN Bus by the FAC 2 MON or the FAC 2 COM -
22-66-00-810-845-A
[8]
Loss of the Reception of the ELAC OPP Bus by the FAC 2 MON or the FAC 2 COM -
22-66-00-810-846-A
[8]
Loss of the Reception of the ELAC OWN Bus by the FAC 1 -
22-66-00-810-847-A
[8]
Loss of the Reception of the ELAC OPP Bus by the FAC 1 -
22-66-00-810-848-A
[8]
Loss of the Reception of the ELAC OWN Bus by the FAC 2 -
22-66-00-810-849-A
[8]
Loss of the Reception of the ELAC OPP Bus the FAC 2 -
22-66-00-810-850-A
[8]
Loss of the Reception of the ELAC 1 Discretes by One FAC or One FMGC -
22-66-00-810-851-A
[8]
Loss of the Reception of the ELAC 2 Discretes by One FAC or One FMGC -
22-66-00-810-852-A
[8]
Loss of the Reception of the SFCC 1 Bus by the FAC 1 -
22-66-00-810-853-A
[8]
Loss of the Reception of the SFCC 2 Bus by the FAC 2 -
22-66-00-810-854-A
[8]
Loss of the Reception of the SFCC 1 SLATS EXTD Discrete by the FAC 1 -
22-66-00-810-855-A
[8]
Loss of the Reception of the SFCC 2 SLATS EXTD Discrete by the FAC 2 -
22-66-00-810-856-A
[8]
Loss of the Reception of the ADIRU 1 Bus by One FAC or One FMGC -
22-66-00-810-857-A
[8]
Loss of the Reception of the ADIRU 2 Bus by One FAC or One FMGC -
22-66-00-810-858-A
[8]
Loss of the Reception of the ADIRU 3 Bus by One FAC or One FMGC -
22-66-00-810-859-A
[8]
Loss of the Data between the ADIRUs and the FAC 1 -
22-66-00-810-860-A
[8]
Loss of the Data between the ADIRUs and the FAC 2 -
22-66-00-810-861-A
[8]
Loss of the Reception of the NOSE GEAR PRESSED Discrete by the FAC 1 -
22-66-00-810-862-A
[8]
Loss of the Reception of the NOSE GEAR PRESSED Discrete by the FAC 2 -
22-66-00-810-863-A
[8]
Loss of the Reception of the ENG STP Discretes by the FAC 1 -
22-66-00-810-864-A
[8]
Loss of the Reception of the ENG STP Discretes by the FAC 2 -
22-66-00-810-865-A
[8]
Discrepancy between the Speed Limits of the PFD 1 and the PFD 2 -
22-66-00-810-866-A
[8]
Loss of the ELAC Functions by the FAC 1 -
22-66-00-810-867-A
[8]
Loss of the ELAC Functions by the FAC 2 -
22-66-00-810-868-A
[8]
FIDS/FAC1 BITE Inoperative -
22-66-00-810-869-A
[8]
FIDS/FAC2 BITE Inoperative -
22-66-00-810-870-A
[8]
FIDS/FMGC1 BITE Inoperative -
22-66-00-810-871-A
[8]
FIDS/FMGC2 BITE Inoperative -
22-66-00-810-872-A
[8]
Loss of the Speed Limits on the Two PFDs -
22-66-00-810-873-A
[8]
FAC 1 Inoperative -
22-66-00-810-874-A
[8]
FAC 2 Inoperative -
22-66-00-810-877-A
[8]
Loss of the Data between the FAC 1 and the FMGC 1 -
22-66-00-810-878-A
[8]
Loss of the Data between the FAC 2 and the FMGC 1 -
22-66-00-810-879-A
[8]
Loss of the Data between the FAC 1 and the FMGC 2 -
22-66-00-810-880-A
[8]
Loss of the Data between the FAC 2 and the FMGC 2 -
22-66-00-810-881-A
[8]
Loss of the SFCC 1 Data -
22-66-00-810-882-A
[8]
Loss of the SFCC 2 Data -
22-66-00-810-883-A
[8]
Access to the MODE MENU Page on the MCDU Inoperative -
22-66-00-810-885-A
[8]
Loss of WINDSHEAR function seen by FAC1 and FAC2 -
22-66-00-810-886-A
[8]
Loss of Yaw Damper and Rudder Trim and Rudder Travel Limitation Functions on the FAC 1 -
22-66-00-810-887-A
[8]
Loss of Yaw Damper and Rudder Trim and Rudder Travel Limitation Functions on the FAC 2 -
22-66-00-810-888-A
[8]
Loss of WINDSHEAR displays (PFD, ECAM) and aural warning -
22-66-00-810-889-A
[8]
Wrong VLS, F, S or Green Dot displays (PFD) -
22-66-00-810-890-A
[8]
Loss of FAC 1 -
22-66-00-810-891-A
[8]
Loss of FAC 2 -
22-66-00-810-892-A
[8]
Failure of the FAC 1 on the rudder trim function (Auto-trim) -
22-66-00-810-893-A
[8]
Wrong speed computation -
22-66-00-810-894-A
[8]
Loss of YD, RT and RTL functions (one of the two sides or the two sides) -
22-66-00-810-895-A
[8]
Wrong ELACs failure during Ground Scanning test without hydraulics -
22-66-00-810-898-A
[8]
Failure of the Angle of Attack Sensor 1 -
22-66-00-810-899-A
[8]
Failure of the Angle of Attack Sensor 2 -
22-66-00-810-900-A
[8]
Failure of the Angle of Attack Sensor 3 -
22-66-00-810-901-A
[8]
Failure of the Angle of Attack Sensors -
22-66-00-810-902-A
[8]
Loss of the TCAS Function of the FMGC Detected by the FAC -
22-66-00-810-903-A
[8]
ROPS Function Inoperative on FAC1 -
22-66-00-810-904-A
[8]
ROPS Function Inoperative on FAC2 -
22-66-00-810-905-A
[8]
ROPS Function Does Not Operate
-