W DOC AIRBUS | TSM A320F

Loss of the TCAS Function of the FMGC Detected by the FAC


TASK 22-66-00-810-902-A
Loss of the TCAS Function of the FMGC Detected by the FAC


1. Possible Causes
  • wiring from the T2CAS computer pins AE/7C, 7D to the FMGC 1 pins AB/3J, 3K and AD/12A, 12B
  • wiring from the T2CAS computer pins AE/7G, 7H to the FMGC 2 pins AB/3J, 3K and AD/12A, 12B
  • wiring from the FAC 1 pins AB/10J, 10K to the terminal block 1860VT
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AWM 226909
ASM 228601
AWM 228618
3. Fault Confirmation
Subtask 22-66-00-740-053-A ** ON A/C NOT FOR ALL
A. Not applicable, you cannot confirm this fault on the ground.
4. Fault Isolation
Subtask 22-66-00-810-187-A ** ON A/C NOT FOR ALL
A. On the Post Flight Report (PFR), do a check for a maintenance message related to the TCAS failure:
   (1) If there is a maintenance message related to the TCAS failure:
  • Do the related trouble shooting procedure.
   (2) If there is no maintenance message related to the TCAS failure:
  • On the PFR, do a check for a maintenance message related to the FMGC/TCAS:
     (a) If there is a maintenance message related to the FMGC/TCAS:
  • For FMGC 1, do a check and repair the wiring from the T2CAS computer pins AE/7C, 7D to the FMGC 1 pins AB/3J, 3K and AD/12A, 12B ASM 228601.
  • For FMGC 2, do a check and repair the wiring from the T2CAS computer pins AE/7G, 7H to the FMGC 2 pins AB/3J, 3K and AD/12A, 12B ASM 228601.
     (b) If there is no maintenance message related to the FMGC/TCAS:
  • Do a check and repair the wiring from the FAC 1 pins AB/10J, 10K to the terminal block 1860VT AWM 226909 AWM 228618.
[Rev.8 from Aug 2018] 2026.04.04 04:25:25 UTC