FIDS/FAC1 BITE Inoperative


TASK 22-66-00-810-868-A
FIDS/FAC1 BITE Inoperative


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-66-34-000-002
Removal of the FAC
AMM 22-66-34-400-002
Installation of the FAC
AMM 22-96-00-710-001
Operational Test of the AFS
AMM 22-97-00-710-001
Operational Test of the LAND CAT III Capability
AMM 24-41-00-861-002
Energize the Aircraft Electrical Circuits from the External Power
AMM 24-41-00-862-002
De-energize the Aircraft Electrical Circuits Supplied from the External Power
3. Fault Confirmation
Subtask 22-66-00-860-056-A
A. Job Set-up
   (1) Aircraft Maintenance Configuration
     (a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
Subtask 22-66-00-865-080-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUAUTO FLT/FAC1/28VDC5CC1B04
49VUAUTO FLT/MCDU/111CA1B01
121VUAUTO FLT/MCDU/211CA2N20
Subtask 22-66-00-710-179-A
C. Test
   (1) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FAC 1.
   (2) Do the operational test of the LAND CAT III Capability AMM 22-97-00-710-001.
4. Fault Isolation
Subtask 22-66-00-810-138-A
A. If the test gives the maintenance related to FIDS-FAC1:
  • open the circuit breaker 5CC1
  • after 15 s, close this circuit breaker
  • do the Test in Para 3.C.
   (1) If the fault continues:
   (2) If the test gives no maintenance message related to FIDS-FAC1:
  • no maintenance action is required.
Subtask 22-66-00-710-180-A
B. Do the test given in Para. 3.
5. Close-up
Subtask 22-66-00-860-057-A
A. Put the aircraft back to its initial configuration.
   (1) On the MCDU, push the line key adjacent to the RETURN indication until the CFDS menu page comes into view.
   (2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.