Failure of the Angle of Attack Sensor 3
TASK 22-66-00-810-900-A
Failure of the Angle of Attack Sensor 3
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-66-00-700-053-A
Subtask 22-66-00-810-185-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:24 UTC
Failure of the Angle of Attack Sensor 3
1. Possible Causes
- SENSOR-ANGLE OF ATTACK, 3 [3FP3]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-11-19-000-001 | Removal of the Angle of Attack Sensor |
| AMM 34-11-19-400-001 | Installation of the Angle of Attack Sensor |
Subtask 22-66-00-700-053-A
A. Not Applicable
4. Fault IsolationSubtask 22-66-00-810-185-A
A. If the maintenance message AFS: AOA PROBE 3 is shown:
- replace the SENSOR-ANGLE OF ATTACK, 3 [3FP3] AMM 34-11-19-000-001 and AMM 34-11-19-400-001.