ROPS Function Inoperative on FAC2
TASK 22-66-00-810-904-A
ROPS Function Inoperative on FAC2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-66-00-710-224-A ** ON A/C NOT FOR ALL
Subtask 22-66-00-810-189-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:25:25 UTC
ROPS Function Inoperative on FAC2
1. Possible Causes
wiring from TAWS computer 1WZ (GPWC) pins AB/1C, 1D to the FAC2 computer (1CC2) pins AA/14J, 14K
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 31-32-00-810-934-A | Failure of the Digital Links |
| ASM 226901 | |
| AMM 34-48-00-740-002 | BITE Test of the GPWS |
| ASM 344801 |
Subtask 22-66-00-710-224-A ** ON A/C NOT FOR ALL
A. Not applicable, you cannot confirm this fault on the ground.
4. Fault IsolationSubtask 22-66-00-810-189-A ** ON A/C NOT FOR ALL
A. If the AFS:TAWS XMTR/FAC2 1CC2 failure message is shown on the Post Flight Report (PFR):
(1) Do the BITE test of the TAWS (GPWS) AMM 34-48-00-740-002.
(a) If the test is not OK, do the related trouble shooting procedure.
(b) If the test is OK:
1 Do a check of the ARINC links between FAC2 and its receivers (Ref. TSM TASK 31-32-00-810-934) with ASM 344801.
2 Do a check and repair thewiring from TAWS computer 1WZ (GPWC) pins AB/1C, 1D to the FAC2 computer (1CC2) pins AA/14J, 14K ASM 226901.
3 If the wiring is OK:
(1) Do the BITE test of the TAWS (GPWS) AMM 34-48-00-740-002.
(a) If the test is not OK, do the related trouble shooting procedure.
(b) If the test is OK:
1 Do a check of the ARINC links between FAC2 and its receivers (Ref. TSM TASK 31-32-00-810-934) with ASM 344801.
2 Do a check and repair the
3 If the wiring is OK:
- Print any TSD for FAC2 and send it back to Airbus for subsequent analysis.