W DOC AIRBUS | TSM A320F

Loss of the Parity Pin Program on the FAC 1


TASK 22-66-00-810-829-A
Loss of the Parity Pin Program on the FAC 1


1. Possible Causes
  • FAC-1 [1CC1]
  • wiring of the ground signal at the programming pins of the FAC 1 (1CC1)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-66-34-000-002
Removal of the FAC
AMM 22-66-34-400-002
Installation of the FAC
ASM 226701
AMM 22-96-00-710-001
Operational Test of the AFS
3. Fault Confirmation
Subtask 22-66-00-710-096-A
A. Test
   (1) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FAC 1.
4. Fault Isolation
Subtask 22-66-00-810-074-A
A. If the test gives the maintenance message AFS : FAC1/PARITY PIN PRG:
   (1) If the fault continues:
  • do a check and repair the wiring of the ground signal at the programming pins of the FAC 1 (1CC1), ASM 226701.
Subtask 22-66-00-710-097-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:25:18 UTC