Loss of the FAC 2 Bus Feedback
TASK 22-66-00-810-806-A
Loss of the FAC 2 Bus Feedback
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-66-00-710-058-A
Subtask 22-66-00-810-055-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:16 UTC
Loss of the FAC 2 Bus Feedback
1. Possible Causes
- FAC-2 [1CC2]
the wiring of the FAC OWN COM bus on the FAC 2 (1CC2) (from pins AE/10A, 10B to the terminal block 1840VT) wiring of the FAC OWN MON bus on the FAC 2 (1CC2)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-66-34-000-002 | Removal of the FAC |
| AMM 22-66-34-400-002 | Installation of the FAC |
| AWM 226902 | |
| AMM 22-96-00-710-001 | Operational Test of the AFS |
Subtask 22-66-00-710-058-A
A. Test
(1) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FAC 2.
4. Fault Isolation(1) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FAC 2.
Subtask 22-66-00-810-055-A
A. If the test gives the maintenance message AFS: FAC 2/C-M ARINC LINK:
Subtask 22-66-00-710-059-A - replace the FAC-2 [1CC2] , AMM 22-66-34-000-002 and AMM 22-66-34-400-002.
- do a check of
the wiring of the FAC OWN COM bus on the FAC 2 (1CC2) (from pins AE/10A, 10B to the terminal block 1840VT) , AWM 226902.
- repair the above mentioned wiring.
- do a check and repair the
wiring of the FAC OWN MON bus on the FAC 2 (1CC2) (from pins AE/12A, 12B to pin AB/7J, 7K) AWM 226902.
B. Do the test given in Para. 3.