W DOC AIRBUS | TSM A320F

Loss of the Yaw Damper Change-Over between the FAC 1 and the FAC 2


TASK 22-66-00-810-820-A
Loss of the Yaw Damper Change-Over between the FAC 1 and the FAC 2


1. Possible Causes
  • FAC-2 [1CC2]
  • wiring of the YAW OPP ENGD COM and YAW OPP ENGD MON discretes (from the FAC 2 (1CC2) to the first terminal block)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-60-00-710-002
Operational Test of the Automatic Change-Over Function
AMM 22-66-34-000-002
Removal of the FAC
AMM 22-66-34-400-002
Installation of the FAC
ASM 226804
AMM 22-96-00-710-001
Operational Test of the AFS
3. Fault Confirmation
Subtask 22-66-00-710-086-A
A. Test
   (1) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FAC 2.
4. Fault Isolation
Subtask 22-66-00-810-069-A
A. If the test gives the maintenance message AFS: FAC 2/YD ENGD CHG-OV:
   (1) If the fault continues:
  • do a check and repair the wiring of the YAW OPP ENGD COM and YAW OPP ENGD MON discretes (from the FAC 2 (1CC2) to the first terminal block), ASM 226804.
Subtask 22-66-00-710-087-A
B. Do the operational test of the automatic change-over function AMM 22-60-00-710-002.
[Rev.8 from Aug 2018] 2026.04.04 04:25:17 UTC