W DOC AIRBUS | TSM A320F

FAC 1 FAULT Legend Comes on without ECAM Warning


TASK 22-66-00-810-836-A
FAC 1 FAULT Legend Comes on without ECAM Warning


1. Possible Causes
  • FAC-1 [1CC1]
  • wiring of the FAC ENGD SW COM and FAC ENGD SW MON discretes (from the FAC 1 (1CC1) to the FLT CTL/FAC 1 pushbutton switch (12CC1))
  • wiring of the 28VDC and GND FAC discretes (from the FAC 1 (1CC1) to the FLT CTL/FAC 1 pushbutton switch (12CC1))
  • RELAY-FAC1 ENGAGED [11CC1]
  • wiring of the FAC ENGD COM and FAC ENGD MON discretes (from the FAC 1 (1CC1) to the FAC 1 ENGAGED relay (11CC1))
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 226501
AMM 22-66-34-000-002
Removal of the FAC
AMM 22-66-34-400-002
Installation of the FAC
AMM 22-96-00-710-001
Operational Test of the AFS
3. Fault Confirmation
Subtask 22-66-00-710-118-A
A. Test
   (1) Do the operational tests of the AFS AMM 22-96-00-710-001 and read the result for the FAC 1:
     (a) with the FLT CTL/FAC1 pushbutton switch (12CC1) released.
     (b) with the FLT CTL/FAC1 pushbutton switch (12CC1) pushed.
4. Fault Isolation
Subtask 22-66-00-810-086-A
A. If only the first test gives the maintenance message AFS: FAC1/P-B SW 12CC1:
   (1) If the fault continues:
  • do a check and repair the wiring of the FAC ENGD SW COM and FAC ENGD SW MON discretes (from the FAC 1 (1CC1) to the FLT CTL/FAC 1 pushbutton switch (12CC1)), ASM 226501.
Subtask 22-66-00-810-087-A
B. If only the second test gives the maintenance message AFS: FAC1/P-B SW 12CC1:
   (1) If the fault continues:
  • do a check of the wiring of the FAC ENGD SW COM and FAC ENGD SW MON discretes (from the FAC 1 (1CC1) to the FLT CTL/FAC 1 pushbutton switch (12CC1)) ASM 226501.
     (a) If there is no continuity:
  • repair the above wiring.
     (b) If there is continuity:
  • do a check and repair the wiring of the 28VDC and GND FAC discretes (from the FAC 1 (1CC1) to the FLT CTL/FAC 1 pushbutton switch (12CC1)), ASM 226501.
Subtask 22-66-00-810-088-A
C. If the two tests do not give the maintenance message:
   (1) If the fault continues:
  • replace the RELAY-FAC1 ENGAGED [11CC1] .
   (2) If the fault continues:
  • do a check and repair the wiring of the FAC ENGD COM and FAC ENGD MON discretes (from the FAC 1 (1CC1) to the FAC 1 ENGAGED relay (11CC1)) ASM 226501.
Subtask 22-66-00-710-119-A
D. Do the test given in Para. 3.A.1.(b).
[Rev.8 from Aug 2018] 2026.04.04 04:25:18 UTC