Loss of the Reception of the ELAC OWN Bus by the FAC 2 MON or the FAC 2 COM


TASK 22-66-00-810-844-A
Loss of the Reception of the ELAC OWN Bus by the FAC 2 MON or the FAC 2 COM


1. Possible Causes
  • FAC-2 [1CC2]
  • wiring of the ELAC OWN bus from the FAC 2 (1CC2) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-66-34-000-002
Removal of the FAC
AMM 22-66-34-400-002
Installation of the FAC
ASM 226901
AMM 22-96-00-710-001
Operational Test of the AFS
3. Fault Confirmation
Subtask 22-66-00-865-061-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUFLIGHT CONTROLS/ELAC2/NORM/SPLY15CE2R20
Subtask 22-66-00-710-136-A
B. Test
   (1) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FAC 2.
4. Fault Isolation
Subtask 22-66-00-810-100-A
A. If the test gives the maintenance message AFS: FAC2/ELAC2 BUS WIRG:
   (1) If the fault continues:
  • do a check and repair the wiring of the ELAC OWN bus from the FAC 2 (1CC2) to the first terminal block ASM 226901.
Subtask 22-66-00-710-137-A
B. Do the test given in Para. 3.