W DOC AIRBUS | TSM A320F

Loss of the Reception of the ELAC OPP Bus by the FAC 1


TASK 22-66-00-810-847-A
Loss of the Reception of the ELAC OPP Bus by the FAC 1


1. Possible Causes
  • wiring between terminal block 1846VT6 pin V and terminal block 1833VT10 pin T
  • wiring between terminal block 1846VT7 pin V and terminal block 1833VT10 pin K
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-91-00-710-001
Ground Scanning of the AFS
AWM 279228
3. Fault Confirmation
Subtask 22-66-00-865-064-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUFLIGHT CONTROLS/ELAC2/NORM/SPLY15CE2R20
Subtask 22-66-00-710-142-A
B. Test
   (1) Do the Ground Scanning of the AFS AMM 22-91-00-710-001.
4. Fault Isolation
Subtask 22-66-00-810-103-B
A. If the test gives the maintenance message AFS: ELAC2/BUS WIRG/FAC1:
  • do a check and repair the:
    . wiring between terminal block 1846VT6 pin V and terminal block 1833VT10 pin T
    . wiring between terminal block 1846VT7 pin V and terminal block 1833VT10 pin K
    AWM 279228.
Subtask 22-66-00-710-143-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:25:19 UTC