Failure of the Angle of Attack Sensors
TASK 22-66-00-810-901-A
Failure of the Angle of Attack Sensors
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 22-66-00-700-054-A
Subtask 22-66-00-810-186-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:25 UTC
Failure of the Angle of Attack Sensors
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 34-11-00-810-861-A | Different Angle of Attack Value on the three ADIRUs |
| AMM 34-11-19-000-001 | Removal of the Angle of Attack Sensor |
| AMM 34-11-19-400-001 | Installation of the Angle of Attack Sensor |
Subtask 22-66-00-700-054-A
A. Not Applicable
4. Fault IsolationSubtask 22-66-00-810-186-A
A. If the maintenance message AFS: AOA PROBE DISAGREE is shown:
- do a visual check of the angle of attack sensors 1 (3FP1), 2 (3FP2) and 3 (3FP3).
- SENSOR-ANGLE OF ATTACK, 1 [3FP1] or/and
- SENSOR-ANGLE OF ATTACK, 2 [3FP2] or/and
- SENSOR-ANGLE OF ATTACK, 3 [3FP3]
AMM 34-11-19-000-001 and AMM 34-11-19-400-001.
- do the trouble shooting related to the different angle of attack value on the three ADIRUs (Ref. TSM TASK 34-11-00-810-861).