Loss of the Reception of the SFCC 2 SLATS EXTD Discrete by the FAC 2
TASK 22-66-00-810-855-A
Loss of the Reception of the SFCC 2 SLATS EXTD Discrete by the FAC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-66-00-865-072-A
Subtask 22-66-00-810-117-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:25:20 UTC
Loss of the Reception of the SFCC 2 SLATS EXTD Discrete by the FAC 2
1. Possible Causes
- FAC-2 [1CC2]
wiring of the SLATS EXTD discrete from the FAC 2 (1CC2) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-66-34-000-002 | Removal of the FAC |
| AMM 22-66-34-400-002 | Installation of the FAC |
| ASM 226801 | |
| AMM 22-91-00-710-001 | Ground Scanning of the AFS |
Subtask 22-66-00-865-072-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 22-66-00-710-158-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | FLIGHT CONTROLS/SLT/CTL/SYS2 | 7CV | R21 |
Subtask 22-66-00-810-117-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message AFS: FAC2-SFCC2 CKT:
Subtask 22-66-00-810-117-B ** ON A/C NOT FOR ALL - replace the FAC-2 [1CC2] AMM 22-66-34-000-002 and AMM 22-66-34-400-002.
- do a check and repair the
wiring of the SLATS EXTD discrete from the FAC 2 (1CC2) to the first terminal block ASM 226801.
A. If the test gives the maintenance message AFS: SFCC2-FAC2 CKT:
Subtask 22-66-00-710-159-A - replace the FAC-2 [1CC2] AMM 22-66-34-000-002 and AMM 22-66-34-400-002.
- do a check and repair the
wiring of the SLATS EXTD discrete from the FAC 2 (1CC2) to the first terminal block ASM 226801.
B. Do the test given in Para. 3