Loss of the Reception of the ELAC OWN Bus by the FAC 1
TASK 22-66-00-810-846-A
Loss of the Reception of the ELAC OWN Bus by the FAC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-66-00-865-063-A
Subtask 22-66-00-810-102-B
[Rev.8 from Aug 2018]
2026.04.04 04:25:19 UTC
Loss of the Reception of the ELAC OWN Bus by the FAC 1
1. Possible Causes
- wiring between terminal block 1835VT18 pin V and terminal block 1831VT9 pin K
- wiring between terminal block 1835VT19 pin V and terminal block 1831VT9 pin C
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-91-00-710-001 | Ground Scanning of the AFS |
| AWM 279229 |
Subtask 22-66-00-865-063-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 22-66-00-710-140-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | FLIGHT CONTROLS/ELAC1/NORM/SPLY | 15CE1 | B11 |
Subtask 22-66-00-810-102-B
A. If the test gives the maintenance message AFS: ELAC1/BUS WIRG/FAC1:
Subtask 22-66-00-710-141-A - do a check and repair the:
. wiring between terminal block 1835VT18 pin V and terminal block 1831VT9 pin K
. wiring between terminal block 1835VT19 pin V and terminal block 1831VT9 pin C
AWM 279229.
B. Do the test given in Para. 3.