W DOC AIRBUS | TSM A320F

Loss of the Rudder Travel-Limiting Change-Over between the FAC 2 and the FAC 1


TASK 22-66-00-810-817-A
Loss of the Rudder Travel-Limiting Change-Over between the FAC 2 and the FAC 1


1. Possible Causes
  • FAC-1 [1CC1]
  • wiring of the RTL OPP ENGD COM and RTL OPP ENGD MON discretes (from the FAC 1 (1CC1) to the first terminal block)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-60-00-710-002
Operational Test of the Automatic Change-Over Function
AMM 22-66-34-000-002
Removal of the FAC
AMM 22-66-34-400-002
Installation of the FAC
ASM 226802
AMM 22-96-00-710-001
Operational Test of the AFS
3. Fault Confirmation
Subtask 22-66-00-710-080-A
A. Test
   (1) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FAC 1.
4. Fault Isolation
Subtask 22-66-00-810-066-A
A. If the test gives the maintenance message AFS: FAC1/RTL ENGD CHG-OV:
   (1) If the fault continues:
  • do a check and repair the wiring of the RTL OPP ENGD COM and RTL OPP ENGD MON discretes (from the FAC 1 (1CC1) to the first terminal block), ASM 226802.
Subtask 22-66-00-710-081-A
B. Do the operational test of the automatic change-over function AMM 22-60-00-710-002.
[Rev.8 from Aug 2018] 2026.04.04 04:25:17 UTC