Loss of WINDSHEAR displays (PFD, ECAM) and aural warning
TASK 22-66-00-810-888-A
Loss of WINDSHEAR displays (PFD, ECAM) and aural warning
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-66-00-710-213-A 4. Fault Isolation
Subtask 22-66-00-810-165-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:23 UTC
Loss of WINDSHEAR displays (PFD, ECAM) and aural warning
1. Possible Causes
FAC1,2 DMC 1,2 FWC 1,2
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-60-00-710-004 | Operational Test of the Windshear Function |
| AMM 22-91-00-710-001 | Ground Scanning of the AFS |
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| AMM 31-60-00-740-004 | EIS System Test |
Subtask 22-66-00-710-213-A 4. Fault Isolation
Subtask 22-66-00-810-165-A
A. If the test not OK with:
. WINDSHEAR not present on PFD and no aural warning
. or/and WINDSHEAR DET FAULT/WINDSHEAR DET not present on ECAM.
(a) do the EIS system test (DMC1 for Capt PFD/EWD, DMC2 for the f/O PFD/SD) (DMC 1,2 ) AMM 31-60-00-740-004.
(b) do the ground scanning of the Central Warning system (FWC 1,2 ) AMM 31-50-00-710-001.
Refer to the above Para. 4.A.(1).
Subtask 22-66-00-810-167-A . WINDSHEAR not present on PFD and no aural warning
. or/and WINDSHEAR DET FAULT/WINDSHEAR DET not present on ECAM.
- do the ground scanning of the AFS (
FAC1,2 ) AMM 22-91-00-710-001.
- do the trouble shooting procedure related to the maintenance message.
(a) do the EIS system test (DMC1 for Capt PFD/EWD, DMC2 for the f/O PFD/SD) (
(b) do the ground scanning of the Central Warning system (
Refer to the above Para. 4.A.(1).
B. If the test not OK with:
. WINDSHEAR not present on PFD but aural warning present:
Subtask 22-66-00-710-214-A . WINDSHEAR not present on PFD but aural warning present:
- Refer to Para. 4.A.(2)(a) (DMC1 & 2).
- Refer to Para. 4.A.(2)(b).
C. Do the test given in Para. 3.