Loss of the Reception of the ELAC OPP Bus by the FAC 2 MON or the FAC 2 COM
TASK 22-66-00-810-845-A
Loss of the Reception of the ELAC OPP Bus by the FAC 2 MON or the FAC 2 COM
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-66-00-865-062-A
Subtask 22-66-00-810-101-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:19 UTC
Loss of the Reception of the ELAC OPP Bus by the FAC 2 MON or the FAC 2 COM
1. Possible Causes
- FAC-2 [1CC2]
wiring of the ELAC OPP bus from the FAC 2 (1CC2) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-66-34-000-002 | Removal of the FAC |
| AMM 22-66-34-400-002 | Installation of the FAC |
| ASM 226901 | |
| AMM 22-96-00-710-001 | Operational Test of the AFS |
Subtask 22-66-00-865-062-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 22-66-00-710-138-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | FLIGHT CONTROLS/ELAC1/NORM/SPLY | 15CE1 | B11 |
B. Test
(1) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FAC 2.
4. Fault Isolation(1) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FAC 2.
Subtask 22-66-00-810-101-A
A. If the test gives the maintenance message AFS: FAC2/ELAC1 BUS WIRG:
Subtask 22-66-00-710-139-A - replace the FAC-2 [1CC2] , AMM 22-66-34-000-002 and AMM 22-66-34-400-002.
- do a check and repair the
wiring of the ELAC OPP bus from the FAC 2 (1CC2) to the first terminal block ASM 226901.
B. Do the test given in Para. 3.