W DOC AIRBUS | TSM A320F

FAC 2 FAULT Legend Comes on without ECAM Warning


TASK 22-66-00-810-837-A
FAC 2 FAULT Legend Comes on without ECAM Warning


1. Possible Causes
  • FAC-2 [1CC2]
  • wiring of the FAC ENGD SW COM and FAC ENGD SW MON discretes (from the FAC 2 (1CC2) to the FLT CTL/FAC 2 pushbutton switch (12CC2))
  • wiring of the 28VDC and GND FAC discretes (from the FAC 2 (1CC2) to the FLT CTL/FAC 2 pushbutton switch (12CC2))
  • RELAY-FAC2 ENGAGED [11CC2]
  • wiring of the FAC ENGD COM and FAC ENGD MON discretes (from the FAC 2 (1CC2) to the FAC 2 ENGAGED relay (11CC2))
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 226501
AMM 22-66-34-000-002
Removal of the FAC
AMM 22-66-34-400-002
Installation of the FAC
AMM 22-96-00-710-001
Operational Test of the AFS
3. Fault Confirmation
Subtask 22-66-00-710-120-A
A. Test
   (1) Do the operational tests of the AFS AMM 22-96-00-710-001 and read the result for the FAC 2:
     (a) with the FLT CTL/FAC 2 pushbutton switch (12CC2) released.
     (b) with the FLT CTL/FAC 2 pushbutton switch (12CC2) pushed.
4. Fault Isolation
Subtask 22-66-00-810-089-A
A. If only the first test gives the maintenance message AFS: FAC2/P-B SW 12CC2:
   (1) If the fault continues:
  • do a check and repair the wiring of the FAC ENGD SW COM and FAC ENGD SW MON discretes (from the FAC 2 (1CC2) to the FLT CTL/FAC 2 pushbutton switch (12CC2)), ASM 226501.
Subtask 22-66-00-810-090-A
B. If only the second test gives the maintenance message AFS: FAC2/P-B SW 12CC2:
   (1) If the fault continues:
  • do a check of the wiring of the FAC ENGD SW COM and FAC ENGD SW MON discretes (from the FAC 2 (1CC2) to the FLT CTL/FAC 2 pushbutton switch (12CC2)) ASM 226501.
     (a) If there is no continuity:
  • repair the above wiring.
     (b) If there is continuity:
  • do a check and repair the wiring of the 28VDC and GND FAC discretes (from the FAC 2 (1CC2) to the FLT CTL/FAC 2 pushbutton switch (12CC2)), ASM 226501.
Subtask 22-66-00-810-091-A
C. If the two tests do not give the maintenance message:
   (1) If the fault continues:
  • replace the RELAY-FAC2 ENGAGED [11CC2] .
   (2) If the fault continues:
  • do a check and repair the wiring of the FAC ENGD COM and FAC ENGD MON discretes (from the FAC 2 (1CC2) to the FAC 2 ENGAGED relay (11CC2)) ASM 226501.
Subtask 22-66-00-710-121-A
D. Do the test given in Para. 3.A.1.(b).
[Rev.8 from Aug 2018] 2026.04.04 04:25:18 UTC