FAC 2 FAULT Legend Comes on without ECAM Warning
TASK 22-66-00-810-837-A
FAC 2 FAULT Legend Comes on without ECAM Warning
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-66-00-710-120-A
Subtask 22-66-00-810-089-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:18 UTC
FAC 2 FAULT Legend Comes on without ECAM Warning
1. Possible Causes
- FAC-2 [1CC2]
wiring of the FAC ENGD SW COM and FAC ENGD SW MON discretes (from the FAC 2 (1CC2) to the FLT CTL/FAC 2 pushbutton switch (12CC2)) wiring of the 28VDC and GND FAC discretes (from the FAC 2 (1CC2) to the FLT CTL/FAC 2 pushbutton switch (12CC2)) - RELAY-FAC2 ENGAGED [11CC2]
wiring of the FAC ENGD COM and FAC ENGD MON discretes (from the FAC 2 (1CC2) to the FAC 2 ENGAGED relay (11CC2))
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 226501 | |
| AMM 22-66-34-000-002 | Removal of the FAC |
| AMM 22-66-34-400-002 | Installation of the FAC |
| AMM 22-96-00-710-001 | Operational Test of the AFS |
Subtask 22-66-00-710-120-A
A. Test
(1) Do the operational tests of the AFS AMM 22-96-00-710-001 and read the result for the FAC 2:
(a) with the FLT CTL/FAC 2 pushbutton switch (12CC2) released.
(b) with the FLT CTL/FAC 2 pushbutton switch (12CC2) pushed.
4. Fault Isolation(1) Do the operational tests of the AFS AMM 22-96-00-710-001 and read the result for the FAC 2:
(a) with the FLT CTL/FAC 2 pushbutton switch (12CC2) released.
(b) with the FLT CTL/FAC 2 pushbutton switch (12CC2) pushed.
Subtask 22-66-00-810-089-A
A. If only the first test gives the maintenance message AFS: FAC2/P-B SW 12CC2:
Subtask 22-66-00-810-090-A - replace the FAC-2 [1CC2] , AMM 22-66-34-000-002 and AMM 22-66-34-400-002.
- do a check and repair the
wiring of the FAC ENGD SW COM and FAC ENGD SW MON discretes (from the FAC 2 (1CC2) to the FLT CTL/FAC 2 pushbutton switch (12CC2)) , ASM 226501.
B. If only the second test gives the maintenance message AFS: FAC2/P-B SW 12CC2:
Subtask 22-66-00-810-091-A - replace the FAC 2 (1CC2) AMM 22-66-34-000-002 and AMM 22-66-34-400-002.
- do a check of the wiring of the FAC ENGD SW COM and FAC ENGD SW MON discretes (from the FAC 2 (1CC2) to the FLT CTL/FAC 2 pushbutton switch (12CC2)) ASM 226501.
- repair the above wiring.
- do a check and repair the
wiring of the 28VDC and GND FAC discretes (from the FAC 2 (1CC2) to the FLT CTL/FAC 2 pushbutton switch (12CC2)) , ASM 226501.
C. If the two tests do not give the maintenance message:
Subtask 22-66-00-710-121-A - replace the FAC 2 (1CC2) AMM 22-66-34-000-002 and AMM 22-66-34-400-002.
- replace the RELAY-FAC2 ENGAGED [11CC2] .
- do a check and repair the
wiring of the FAC ENGD COM and FAC ENGD MON discretes (from the FAC 2 (1CC2) to the FAC 2 ENGAGED relay (11CC2)) ASM 226501.
D. Do the test given in Para. 3.A.1.(b).