Loss of the Reception of the ELAC 2 Discretes by One FAC or One FMGC
TASK 22-66-00-810-851-A
Loss of the Reception of the ELAC 2 Discretes by One FAC or One FMGC
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-66-00-865-068-A
Subtask 22-66-00-810-110-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:19 UTC
Loss of the Reception of the ELAC 2 Discretes by One FAC or One FMGC
1. Possible Causes
- FAC-1 [1CC1]
wiring of the ELAC OPP HLTY COM discrete from the FAC 1 (1CC1) to the first terminal block - FAC-2 [1CC2]
wiring of the ELAC OWN HLTY MON discrete from the FAC 2 (1CC2) to the first terminal block - FMGC-1 [1CA1]
- ELAC-2 [2CE2]
wiring of the ELAC OPP AP DISC MON and ELAC OPP AP DISC COM discretes from the FMGC 1 (1CA1) to the ELAC 2 (2CE2) - FMGC-2 [1CA2]
wiring of the ELAC OWN AP DISC MON and ELAC OWN AP DISC COM discretes from the FMGC 2 (1CA2) to the ELAC 2 (2CE2)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-66-34-000-002 | Removal of the FAC |
| AMM 22-66-34-400-002 | Installation of the FAC |
| ASM 226801 | |
| AMM 22-83-34-000-001 | Removal of the FMGC |
| AMM 22-83-34-400-001 | Installation of the FMGC |
| ASM 228504 | |
| AMM 22-96-00-710-001 | Operational Test of the AFS |
| AMM 27-93-34-000-001 | Removal of the ELAC |
| AMM 27-93-34-400-001 | Installation of the ELAC |
Subtask 22-66-00-865-068-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 22-66-00-710-150-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | FLIGHT CONTROLS/ELAC1/NORM/SPLY | 15CE1 | B11 |
| 121VU | FLIGHT CONTROLS/ELAC2/NORM/SPLY | 15CE2 | R20 |
B. Test
(1) Do the test of the AFS AMM 22-96-00-710-001.
4. Fault Isolation(1) Do the test of the AFS AMM 22-96-00-710-001.
NOTE: When the APU is under MMEL, the AFS: ELAC2 message can possibly come into view before the second engine starts.
If the failure message comes into view, it will go out of view when the two engines run (but the failure message will be recorded in the PFR).
If the APU is under MMEL and if the test of the AFS is correct, no maintenance action is necessary.
If the failure message comes into view, it will go out of view when the two engines run (but the failure message will be recorded in the PFR).
If the APU is under MMEL and if the test of the AFS is correct, no maintenance action is necessary.
Subtask 22-66-00-810-110-A
A. If the test gives the maintenance message AFS: ELAC2 (ISSUED BY: FAC1):
Subtask 22-66-00-810-111-A - replace the FAC-1 [1CC1] AMM 22-66-34-000-002 and AMM 22-66-34-400-002.
- do a check and repair the
wiring of the ELAC OPP HLTY COM discrete from the FAC 1 (1CC1) to the first terminal block ASM 226801.
B. If the test gives the maintenance message AFS: ELAC2 (ISSUED BY: FAC2):
Subtask 22-66-00-810-112-A - replace the FAC-2 [1CC2] AMM 22-66-34-000-002 and AMM 22-66-34-400-002.
- do a check and repair the
wiring of the ELAC OWN HLTY MON discrete from the FAC 2 (1CC2) to the first terminal block ASM 226801.
C. If the test gives the maintenance message AFS: ELAC2 (ISSUED BY: FG1):
Subtask 22-66-00-810-113-A - replace the FMGC-1 [1CA1] AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
- replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
- do a check and repair the
wiring of the ELAC OPP AP DISC MON and ELAC OPP AP DISC COM discretes from the FMGC 1 (1CA1) to the ELAC 2 (2CE2) ASM 228504.
D. If the test gives the maintenance message AFS: ELAC2 (ISSUED BY: FG2):
Subtask 22-66-00-710-151-A - replace the FMGC-2 [1CA2] AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
- replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
- do a check and repair the
wiring of the ELAC OWN AP DISC MON and ELAC OWN AP DISC COM discretes from the FMGC 2 (1CA2) to the ELAC 2 (2CE2) ASM 228504.
E. Do the test given in Para. 3.