Wrong VLS, F, S or Green Dot displays (PFD)
TASK 22-66-00-810-889-A
Wrong VLS, F, S or Green Dot displays (PFD)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-66-00-710-215-A
Subtask 22-66-00-810-166-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:24 UTC
Wrong VLS, F, S or Green Dot displays (PFD)
1. Possible Causes
- Angle of attack value is different on the three ADIRUs
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 34-11-00-810-861-A | Different Angle of Attack Value on the three ADIRUs |
Subtask 22-66-00-710-215-A
A. Test
(1) Not applicable.
4. Fault Isolation(1) Not applicable.
Subtask 22-66-00-810-166-A
A. If, on the PFD, the indications VLS, F, S or Green Dot are incorrect:
- if the Angle of attack value is different on the three ADIRUs , do the trouble shooting procedure (Ref. TSM TASK 34-11-00-810-861).