Loss of the Rudder Trim Change-Over between the FAC 1 and the FAC 2
TASK 22-66-00-810-816-A
Loss of the Rudder Trim Change-Over between the FAC 1 and the FAC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-66-00-710-078-A
Subtask 22-66-00-810-065-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:17 UTC
Loss of the Rudder Trim Change-Over between the FAC 1 and the FAC 2
1. Possible Causes
- FAC-2 [1CC2]
wiring of the RUD TR OPP ENGD COM and RUD TR OPP ENGD MON discretes (from the FAC 2 (1CC2) to the first terminal block)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-60-00-710-002 | Operational Test of the Automatic Change-Over Function |
| AMM 22-66-34-000-002 | Removal of the FAC |
| AMM 22-66-34-400-002 | Installation of the FAC |
| ASM 226803 | |
| AMM 22-96-00-710-001 | Operational Test of the AFS |
Subtask 22-66-00-710-078-A
A. Test
(1) Do the operational test for the AFS AMM 22-96-00-710-001 and read the result of the FAC 2.
4. Fault Isolation(1) Do the operational test for the AFS AMM 22-96-00-710-001 and read the result of the FAC 2.
NOTE: If you did the deactivation of:
- the channel 1 of the rudder trim actuator (relay 7CC1 removed) or
- the channel 1 of the rudder travel limitation unit (relay 13CC1 removed)
You can ignore the failure message "FAC2/RT ENGD CHG-OV".
- the channel 1 of the rudder trim actuator (relay 7CC1 removed) or
- the channel 1 of the rudder travel limitation unit (relay 13CC1 removed)
You can ignore the failure message "FAC2/RT ENGD CHG-OV".
Subtask 22-66-00-810-065-A
A. If the test gives the maintenance message AFS: FAC2/RT ENGD CHG-OV:
Subtask 22-66-00-710-079-A - Replace the FAC-2 [1CC2] , AMM 22-66-34-000-002 and AMM 22-66-34-400-002.
- Do a check and repair the
wiring of the RUD TR OPP ENGD COM and RUD TR OPP ENGD MON discretes (from the FAC 2 (1CC2) to the first terminal block) , ASM 226803.