32-31 NORMAL EXTENSION AND RETRACTION
- PB.201 NORMAL EXTENSION AND RETRACTION - FAULT ISOLATION PROCEDURES
-
32-31-00-810-801-A
[8]
No Data from CFDIU. Interactive Mode Selection #amp# Monitor Sequence Fault -
32-31-00-810-802-A
[8]
LGCIU Fault -
32-31-00-810-804-A
[8]
LGCIU Selection. Hardware/Control Determination. -
32-31-00-810-806-A
[8]
L/G Selector Valve Fault -
32-31-00-810-807-A
[8]
L/G Doors Selector Valve System Fault -
32-31-00-810-808-A
[8]
L/G and Doors Will Not Operate After Selection -
32-31-00-810-809-A
[8]
L/G Selector Lever Deselection -
32-31-00-810-813-A
[8]
R MLG Compressed/Extended Proximity Sensor Failed to Flight Condition -
32-31-00-810-814-A
[8]
L MLG Compressed/Extended Proximity Sensor Failed to Flight Condition -
32-31-00-810-815-A
[8]
NLG Compressed/Extended Proximity Sensor Fault -
32-31-00-810-816-A
[8]
RLG Door Open Proximity Sensor Fault -
32-31-00-810-817-A
[8]
LLG Door Open Proximity Sensor Fault -
32-31-00-810-818-A
[8]
NLG Door Open Proximity Sensor Fault -
32-31-00-810-819-A
[8]
RLG Door Closed Proximity Sensor Fault -
32-31-00-810-820-A
[8]
LLG Door Closed Proximity Sensor Fault -
32-31-00-810-821-A
[8]
NLG Door Closed Proximity Sensor Fault -
32-31-00-810-822-A
[8]
RLG Downlock Proximity Sensor Fault -
32-31-00-810-823-A
[8]
LLG Downlock Proximity Sensor Fault -
32-31-00-810-824-A
[8]
NLG Downlock Proximity Sensor Fault -
32-31-00-810-825-A
[8]
RLG Uplock Proximity Sensor Fault (8GA, 10GA) -
32-31-00-810-826-A
[8]
LLG Uplock Proximity Sensor Fault (9GA, 11GA) -
32-31-00-810-827-A
[8]
NLG Uplock Proximity Sensor Fault -
32-31-00-810-828-A
[8]
Left Flap Disconnect Proximity Sensor -
32-31-00-810-829-A
[8]
Right Flap Disconnect Proximity Sensor -
32-31-00-810-830-A
[8]
Cargo Door (Fwd) Handle Proximity Sensor Fault (28WV) -
32-31-00-810-831-A
[8]
Cargo Door (Aft) Handle Proximity Sensor Fault (34WV) -
32-31-00-810-832-A
[8]
Cargo Door (Fwd) Safety Mechanism Proximity Sensor Fault (30WV) -
32-31-00-810-833-A
[8]
Cargo Door (Aft) Safety Mechanism Proximity Sensor Fault (32WV) -
32-31-00-810-834-A
[8]
Cargo Door (Fwd) Lockshaft Proximity Sensor Fault (5MJ) -
32-31-00-810-835-A
[8]
Cargo Door (Aft) Lockshaft Proximity Sensor Fault (12MJ) -
32-31-00-810-836-A
[8]
L/G Uplock or Downlock fault -
32-31-00-810-837-A
[8]
L/G or L/G Door Uplock TGT POS Fault (sensors 8GA thru 13GA and 26GA thru 31GA) -
32-31-00-810-839-A
[8]
LGCIU BITE Test Not Possible -
32-31-00-810-840-A
[8]
L/G Door Fully Open Proximity Sensor TGT POS Fault (32GA thru 39GA) -
32-31-00-810-842-A
[8]
L/G Shock Absorber Extended Proximity Sensor TGT POS Fault (20GA thru 25GA) -
32-31-00-810-843-A
[8]
LGCIU - EFCS Reports Loss of Data from LGCIU 1 Bus 2 -
32-31-00-810-844-A
[8]
LGCIU - Loss of Data by the SEC,DMC,FWC,DMU,FAC or SFCC from LGCIU 1 or LGCIU 2 -
32-31-00-810-845-A
[8]
LGCIU - EFCS Reports Loss of Data from LGCIU 2 Bus 2 -
32-31-00-810-846-A
[8]
L/G Failure of one of the uplock proximity sensors 8GA thru 13GA -
32-31-00-810-849-A
[8]
L/G Failure Of The L/G Safety Valve Power Interrupt Test -
32-31-00-810-850-A
[8]
L/G Fault Code H138 or H146 is Shown in LGCIU Trouble Shooting Data -
32-31-00-810-851-A
[8]
L/G - NLG Shock Absorber Fault -
32-31-00-810-852-A
[8]
LGCIU - VOR Interface Fault -
32-31-00-810-853-A
[8]
L/G Doors Uncommanded Opening in Flight -
32-31-00-810-855-A
[8]
MLG Vibration and Noise During Retraction and Exetension, and/or MLG FWD Pintle Bearing Lubrication Difficult -
32-31-00-810-856-A
[8]
NLG Doors Do Not Open Fully -
32-31-00-810-857-A
[8]
MLG Door (LH) Does Not Open Fully -
32-31-00-810-858-A
[8]
MLG Door (RH) Does Not Open Fully -
32-31-00-810-859-A
[8]
NLG Doors Do Not Close Fully or Slow to Operate -
32-31-00-810-860-A
[8]
MLG Door (LH) Does Not Close Fully or Slow to Operate -
32-31-00-810-861-A
[8]
MLG Door (RH) Does Not Close Fully or Slow to Operate -
32-31-00-810-862-A
[8]
NLG Does Not Downlock -
32-31-00-810-863-A
[8]
MLG (LH) Does Not Downlock -
32-31-00-810-864-A
[8]
MLG (RH) Does Not Downlock -
32-31-00-810-865-A
[8]
NLG Does Not Uplock -
32-31-00-810-866-A
[8]
MLG (LH) Does Not Uplock -
32-31-00-810-867-A
[8]
MLG (RH) Does Not Uplock -
32-31-00-810-868-A
[8]
NLG Shock Absorber Does Not Extend (L/G will not retract) -
32-31-00-810-869-A
[8]
MLG (LH) Shock Absorber Does Not Extend -
32-31-00-810-870-A
[8]
MLG (RH) Shock Absorber Does Not Extend -
32-31-00-810-872-A
[8]
LGCIU 1 (2) Fault -
32-31-00-810-875-A
[8]
L/G Uplock Locked When L/G is Locked Down -
32-31-00-810-876-A
[8]
NLG Shock Absorber - Sliding Tube Oil Seepage or Unusual Extension (Specially when Off-loading) -
32-31-00-810-877-A
[8]
FWD Cargo - Door Indication Proximity-Switch TGT POS Fault (5MJ, 28WV, 30WV) -
32-31-00-810-879-A
[8]
LGCIU - No Data from CFDS -
32-31-00-810-880-A
[8]
L/G Shock Absorber Fault -
32-31-00-810-881-A
[8]
LGCIU - The EFCS Does Not Receive Data from the LGCIU -
32-31-00-810-882-A
[8]
L/G - GEAR NOT DOWN Message Caused by Downlock Proximity Switch Fault (14GA thru 19GA) -
32-31-00-810-883-A
[8]
L/G - Gear Selector Valve or Door Selector Valve Fault -
32-31-00-810-884-A
[8]
L/G - VHF Transceiver Does Not Get Data from the LGCIU -
32-31-00-810-885-A
[8]
L/G - Lever Does Not Move - Retraction Inhibit Baulk Solenoid Does Not Release -
32-31-00-810-886-A
[8]
Aft Cargo - Door Indication Proximity-Switch TGT POS Fault (12MJ, 32WV, 34WV) -
32-31-00-810-887-A
[8]
L/G - SYS DISAGREE and MLG L Amber XX Shown, Aircraft on Ground, or a System Unusual Ground/Flight Condition or Indication -
32-31-00-810-888-A
[8]
L/G SYS DISAGREE With No LGCIU BITE Message -
32-31-00-810-889-A
[8]
LGCIU ARINC BUS Internal Feedback -
32-31-00-810-890-A
[8]
LGCIU Incompatible With Aircraft Type -
32-31-00-810-891-A
[8]
LGCIU Power Supply Interruption -
32-31-00-810-892-A
[8]
LGCIU Auto Reset Fault -
32-31-00-810-893-A
[8]
LGCIU Ground Power and 70Kts Inputs Inconsistent -
32-31-00-810-894-A
[8]
LGCIU System ID Inconsistent With Proximity Sensors -
32-31-00-810-895-A
[8]
L/G - Gear Indicator Lights Flickering -
32-31-00-810-896-A
[8]
L/G Downlock Proximity Sensor TGT POS Fault (sensors 14GA thru 19GA) -
32-31-00-810-898-A
[8]
L/G - All Landing Gears and all Landing Gear Doors Slow Operation -
32-31-00-810-899-A
[8]
FWD Cargo Door LGCIU 2 Control Fault -
32-31-00-810-900-A
[8]
AFT Cargo Door LGCIU 2 Control Fault -
32-31-00-810-901-A
[8]
'LG EXT PROX SNSR TGT POS' and(or) 'LG SHOCK ABSORBER' Fault Message(s) is(are) shown on the PFR after the First Flight-Cycle after Maintenance
-
32-31-00-810-801-A
[8]
- PB.301 NORMAL EXTENSION AND RETRACTION - TASK SUPPORTING DATA