LGCIU - EFCS Reports Loss of Data from LGCIU 2 Bus 2
TASK 32-31-00-810-845-A
LGCIU - EFCS Reports Loss of Data from LGCIU 2 Bus 2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 32-31-00-710-062-A
Subtask 32-31-00-810-096-A
[Rev.8 from Aug 2018]
2026.04.04 04:31:23 UTC
LGCIU - EFCS Reports Loss of Data from LGCIU 2 Bus 2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AWM 279251 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
| AMM 32-31-71-000-001 | Removal of the LGCIU |
| AMM 32-31-71-400-001 | Installation of the LGCIU |
| AWM 326106 |
Subtask 32-31-00-710-062-A
A. Test
(1) Do a check of the Post Flight Report (PFR) to see if other systems have also identified the same fault.
4. Fault Isolation(1) Do a check of the Post Flight Report (PFR) to see if other systems have also identified the same fault.
NOTE: If other systems also identify the same loss of data, the fault will be in the LGCIU, or the bus wiring which is the same for all those systems. If only one system has identified the loss of data, the fault will be in that system or the wiring which is applicable to that system only.
(2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001- if the message NO FAULTS RECORDED is shown, no other maintenance work is necessary
- if the message LGCIU2 BUS2 is shown do the fault isolation procedure in Para. 4.A.
Subtask 32-31-00-810-096-A
A. Procedure
(1) Interchange the LGCIU-2 with the LGCIU-1 AMM 32-31-71-000-001, AMM 32-31-71-400-001.
(a) Do the test in Para. 3.A.(2):
(a) Do the test in Para. 3.A.(2):
(a) Do the test in Para. 3.A.(2):
(5) Do the test in Para. 3.A.(2).
(1) Interchange the LGCIU-2 with the LGCIU-1 AMM 32-31-71-000-001, AMM 32-31-71-400-001.
(a) Do the test in Para. 3.A.(2):
- if the fault continues, do step (3)
- if the fault goes, do the next step.
(a) Do the test in Para. 3.A.(2):
- if the fault continues and has been identified by other systems, do step (4)
- if the fault continues and has been identified by the EFCS only, do the next step.
(a) Do the test in Para. 3.A.(2):
- if the fault continues, do the next step.
(5) Do the test in Para. 3.A.(2).