W DOC AIRBUS | TSM A320F

MLG Door (LH) Does Not Close Fully or Slow to Operate


TASK 32-31-00-810-860-A
MLG Door (LH) Does Not Close Fully or Slow to Operate


WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. MOVEMENT OF THE LANDING GEAR CAN CAUSE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
1. Possible Causes
  • LH MLG door retraction system components
  • LH MLG door clearance
  • LH MLG door uplock unit and rollers
  • LH MLG door forward and aft fittings
  • UPLOCK ASSY-MLG DOOR, L [2521GM]
  • 2523GM
  • BYPASS VALVE-MLG DOOR GROUND OPENING, L [2517GM]
  • [41GA]
  • MANIFOLD ASSY-L/G AND DOOR SELECTOR VALVES [2524GM]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 32-31-00-810-898-A
L/G - All Landing Gears and all Landing Gear Doors Slow Operation
AMM 32-12-00-710-002
Operational Test of the Main Landing Gear (MLG) Doors Ground-Opening-Mechanism
AMM 32-12-11-400-001
Installation of the Door Assembly - Main
AMM 32-31-00-200-001
Detailed Inspection of Gear Uplock and Door Uplock Units and Rollers
AMM 32-31-00-200-003
Detailed Inspection of Retraction Actuator
AMM 32-31-00-210-002
General Visual Inspection of L/G Extension/Retraction System Components
AMM 32-31-00-720-002
Functional Test of the Normal Extension and Retraction of the Landing Gear
AMM 32-31-13-000-001
Removal of the MLG Door Ground-Opening Bypass-Valve
AMM 32-31-13-400-001
Installation of the MLG Door Ground-Opening Bypass-Valve
AMM 32-31-31-000-001
Removal of the Selector-Valve Manifold Assembly
AMM 32-31-31-400-001
Installation of the Selector-Valve Manifold Assembly
AMM 32-31-33-000-001
Removal of the MLG Door Uplock 2520GM
AMM 32-31-33-400-002
Installation of the MLG Door Uplock 2520GM
AMM 32-31-34-000-001
Removal of the Landing-Gear (L/G) Door Selector Valve
AMM 32-31-34-400-001
Installation of the Landing-Gear (L/G) Door Selector Valve
AMM 32-31-35-000-001
Removal of the MLG Door Actuating-Cylinder
AMM 52-81-00-200-001
Detailed Inspection of MLG Door, Forward and Aft Fittings, LH/RH
3. Fault Confirmation
Subtask 32-31-00-860-092-A
A. Test
   (1) Do a check of the Post Flight Report:
  • if two CFDS L L/G DOOR CLOSED PROX SNSR TGT POS messages related to the same door, for the same flight are shown
    or
  • if the ECAM WARNING, DOORS NOT CLOSED message with two CFDS L L/G DOOR CLOSED PROX SNSR TGT POS messages related to the same door are shown
    or
  • if the MLG door was difficult to open on the ground.
     (a) Do the fault isolation procedure in para 4.A.
4. Fault Isolation
Subtask 32-31-00-810-118-A
A. Procedure
   (1) Do the detailed inspection of the LH MLG door retraction system components AMM 32-31-00-200-003 and AMM 32-31-00-210-002.
   (2) Do a check of the LH MLG door clearance AMM 32-12-11-400-001.
   (3) Do the detailed inspection of the LH MLG door uplock unit and rollers AMM 32-31-00-200-001.
   (4) Do the detailed inspection of the LH MLG door forward and aft fittings AMM 52-81-00-200-001.
   (5) Correct all the faults that you find.
   (6) Do the Functional Test of the Normal Extension and Retraction System AMM 32-31-00-720-002.
   (7) If the MLG doors close in the correct time but do not uplock:
     (a) Replace the UPLOCK ASSY-MLG DOOR, L [2521GM] AMM 32-31-33-000-001 and AMM 32-31-33-400-002.
   (8) If the fault continues:
     (a) Operate the MLG doors 10 times. Use the Ground Door Opening handle AMM 32-12-00-710-002.
NOTE: This will bleed the door open/close hydraulic system.
   (9) If the fault continues:
     (a) Replace the 2523GM AMM 32-31-35-000-001 and AMM 32-31-35-000-001.
   (10) If the fault continues:
     (a) Replace the BYPASS VALVE-MLG DOOR GROUND OPENING, L [2517GM] AMM 32-31-13-000-001 and AMM 32-31-13-400-001.
   (11) If the fault continues:
     (a) Replace the [41GA] AMM 32-31-34-000-001 and AMM 32-31-34-400-001.
     (b) Replace the MANIFOLD ASSY-L/G AND DOOR SELECTOR VALVES [2524GM] AMM 32-31-31-000-001 and AMM 32-31-31-400-001.
   (12) If the fault continues:
     (a) Do the TSM task (Ref. TSM TASK 32-31-00-810-898).
5. Close-up
Subtask 32-31-00-942-060-A
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
[Rev.8 from Aug 2018] 2026.04.04 04:31:24 UTC