LGCIU - Loss of Data by the SEC,DMC,FWC,DMU,FAC or SFCC from LGCIU 1 or LGCIU 2
TASK 32-31-00-810-844-A
LGCIU - Loss of Data by the SEC,DMC,FWC,DMU,FAC or SFCC from LGCIU 1 or LGCIU 2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 32-31-00-710-061-A
Subtask 32-31-00-810-095-A
[Rev.8 from Aug 2018]
2026.04.04 04:31:23 UTC
LGCIU - Loss of Data by the SEC,DMC,FWC,DMU,FAC or SFCC from LGCIU 1 or LGCIU 2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 32-31-71-000-001 | Removal of the LGCIU |
| AMM 32-31-71-400-001 | Installation of the LGCIU |
| ASM 326104 |
Subtask 32-31-00-710-061-A
A. Test
(1) Select MCDU MENU mode and set the CFDS menu, then access the A/C CURRENT STATUS page.
(2) Do a check of the STATUS report and look for an LGCIU 1 (2) fault from the SEC, DMC, FWC, DMU, FAC and SFFC:
4. Fault Isolation(1) Select MCDU MENU mode and set the CFDS menu, then access the A/C CURRENT STATUS page.
(2) Do a check of the STATUS report and look for an LGCIU 1 (2) fault from the SEC, DMC, FWC, DMU, FAC and SFFC:
- If only one of the units reports a fault, do the trouble shooting procedure related to the maintenance message applicable to the unit that reported the fault
- If more than one of these units report a fault, do the Fault Isolation procedure in Para. 4.
NOTE: The ATA references for the related sytems are as follows:
- SEC (27-95-00)
- DMC (31-63-00)
- FWC (31-53-00)
- DMU (31-36-00)
- FAC (22-66-00)
- SFCC (27-51-00)
Subtask 32-31-00-810-095-A
A. Procedure
(2) Do the test in Para. 3.A:
(4) Do the test in Para. 3.A:
(6) Do the test in para 3.A.
NOTE: This fault isolation procedure is for an LGCIU loss of data fault, reported by other units connected to the LGCIU by an ARINC data-bus.
(1) Interchange the two LGCIU AMM 32-31-71-000-001 and AMM 32-31-71-400-001, (2) Do the test in Para. 3.A:
- if the fault stays in the LGCIU system shown on the PFR, go to step (5)
- if the fault moves to the opposite LGCIU system, do the next step
(4) Do the test in Para. 3.A:
- if the fault continues, do the next step.
(6) Do the test in para 3.A.