LGCIU - The EFCS Does Not Receive Data from the LGCIU
TASK 32-31-00-810-881-A
LGCIU - The EFCS Does Not Receive Data from the LGCIU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 32-31-00-710-072-A
Subtask 32-31-00-810-139-A
[Rev.8 from Aug 2018]
2026.04.04 04:31:26 UTC
LGCIU - The EFCS Does Not Receive Data from the LGCIU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-860-001 | EIS Start Procedure |
| ASM 323103 | |
| ASM 323104 | |
| AMM 32-31-71-000-001 | Removal of the LGCIU |
| AMM 32-31-71-400-001 | Installation of the LGCIU |
Subtask 32-31-00-710-072-A
A. Test
(1) Do the EIS Start Procedure (Upper and Lower ECAM DU only) AMM 31-60-00-860-001.
(2) At the ECAM Control Panel set the STS page.
(3) Look at the Status Page for the message LGCIU 1 (2).
4. Fault Isolation(1) Do the EIS Start Procedure (Upper and Lower ECAM DU only) AMM 31-60-00-860-001.
(2) At the ECAM Control Panel set the STS page.
(3) Look at the Status Page for the message LGCIU 1 (2).
- if the message is shown, do the fault isolation procedure in Para. 4.A.
- if the message is not shown, there is no LGCIU 1 (2) fault.
Subtask 32-31-00-810-139-A
A. Procedure
(1) Interchange LGCIU 1 with LGCIU 2, AMM 32-31-71-000-001 and AMM 32-31-71-400-001.
(2) Do the test in Para. 3.A:
(4) Make sure that the serviceable LGCIU is installed in its initial position.
(5) Do the test in Para. 3.A:
(7) Do the test in Para. 3.A.
(1) Interchange LGCIU 1 with LGCIU 2, AMM 32-31-71-000-001 and AMM 32-31-71-400-001.
(2) Do the test in Para. 3.A:
- if the fault stays in the initial system (identified in the failure message), do step (5)
- if the fault moves to the opposite system, do the next step.
(4) Make sure that the serviceable LGCIU is installed in its initial position.
(5) Do the test in Para. 3.A:
- if the fault continues do the next step.
(7) Do the test in Para. 3.A.