W DOC AIRBUS | TSM A320F

L/G SYS DISAGREE With No LGCIU BITE Message


TASK 32-31-00-810-888-A
L/G SYS DISAGREE With No LGCIU BITE Message


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
1. Possible Causes
  • PROX SNSR-NLG DOORS CLOSED, SYS 1 [30GA]
  • PROX SNSR-L L/G DOOR CLOSED, SYS 1 [27GA]
  • PROX SNSR-R L/G DOOR CLOSED, SYS 1 [26GA]
  • UPLOCK ASSY-NLG DOOR [2534GM]
  • UPLOCK ASSY-MLG DOOR, R [2520GM]
  • UPLOCK ASSY-MLG DOOR, L [2521GM]
  • PROX SNSR-NLG DOORS CLOSED, SYS 2 [31GA]
  • PROX SNSR-L L/G DOOR CLOSED, SYS 2 [29GA]
  • PROX SNSR-R L/G DOOR CLOSED, SYS 2 [28GA]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-32-00-860-009
Procedure to Get Access to the SYSTEM REPORT/TEST/L/G Page
AMM 32-00-00-860-001
Flight Configuration Precautions with Electrical Power
AMM 32-31-14-000-001
Removal of the NLG Door Uplock Assy
AMM 32-31-14-400-001
Installation of the NLG Door Uplock Assy
AMM 32-31-33-000-001
Removal of the MLG Door Uplock 2520GM
AMM 32-31-33-400-002
Installation of the MLG Door Uplock 2520GM
AMM 32-31-73-000-001
Removal of the MLG Proximity-Sensors
AMM 32-31-73-000-005
Removal of the NLG Proximity-Sensors
AMM 32-31-73-400-001
Installation of the MLG Proximity-Sensors
AMM 32-31-73-400-005
Installation of the NLG Proximity-Sensors
AMM 32-31-73-820-008
Inductance Check of the Proximity Sensors/Switches
3. Fault Confirmation
Subtask 32-31-00-710-077-A
A. Test
   (1) Before the L/G doors are opened for maintenance:
     (a) Get access to the L/G SYSTEM/REPORT/TEST L/G page AMM 31-32-00-860-009.
     (b) Do a check of the LAST LEG REPORT and the GROUND SCANNING of LGCIU 1 and 2.
     (c) If a fault message is shown do the applicable troubleshooting procedure.
NOTE: If the L/G doors are opened for maintenance before you get access to the LGCIU LAST LEG REPORT and the GROUND SCANNING. A message unrelated to the defect will be shown.
NOTE: The ECAM WARNING "L/G SYS DISAGREE" is inhibited during flight phases, 03, 04, 05, 07 and 08.
   (2) If no maintenance message is shown:
     (a) Do the trouble shooting from Para. 4.
4. Fault Isolation
Subtask 32-31-00-865-065-A
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUL/G/LGCIU/SYS1/NORM1GAC09
121VUHYDRAULIC/LGCIU/SYS22GAQ35
121VUHYDRAULIC/LGCIU/SYS1/GRND SPLY52GAQ34
Subtask 32-31-00-810-150-A
B. Procedure
   (1) Make sure that all the L/G doors are in the closed position.
   (2) Do the flight configuration precautions, AMM 32-00-00-860-001, make sure the aircraft has ground electrical power.
   (3) To put LGCIU 1 in control:
     (a) Make sure C/B's 1GA and 52GA are closed and open the C/B 2GA.
     (b) On the ECAM WHEEL PAGE make sure that the L/G door indication shows all the doors closed.
   (4) If the L/G door indication is correct, go to step (12).
   (5) If a L/G door indication does not show closed:
     (a) Do an inductance test of the applicable proximity sensor AMM 32-31-73-820-008:
  • for the NLG door PROX SNSR-NLG DOORS CLOSED, SYS 1 [30GA]
  • for the L MLG door PROX SNSR-L L/G DOOR CLOSED, SYS 1 [27GA]
  • for the R MLG door PROX SNSR-R L/G DOOR CLOSED, SYS 1 [26GA] .
   (6) If no defect is found continue at step (12).
   (7) If a defect is found, replace the applicable proximity sensor:
   (8) Do the test in steps (1) thru (3) again.
   (9) If the fault continues:
     (a) Replace the applicable uplock:
   (10) Do the test in steps (1) thru (3)again.
   (11) Close the C/B 2GA.

   (12) To troubleshoot System 2:
     (a) Make sure that all the L/G doors are in the closed position.
     (b) Do the flight configuration precautions, AMM 32-00-00-860-001, make sure the aircraft has electrical power.
   (13) To put LGCIU 2 in control:
     (a) Make sure C/B 2GA is closed and open the C/B's 1GA and 52GA.
     (b) On the ECAM WHEEL PAGE make sure that the L/G door indication shows all the doors closed.
   (14) If a L/G door indication does not show closed:
     (a) Do an inductance test of the applicable proximity sensor AMM 32-31-73-820-008:
  • for the NLG door PROX SNSR-NLG DOORS CLOSED, SYS 2 [31GA]
  • for the L MLG door PROX SNSR-L L/G DOOR CLOSED, SYS 2 [29GA]
  • for the R MLG door PROX SNSR-R L/G DOOR CLOSED, SYS 2 [28GA] .
   (15) Replace the defective proximity sensor:
   (16) Do the test in steps (12) and (13)again.
   (17) If the fault continues:
     (a) Replace the applicable uplock:
   (18) Do the test in steps (12) and (13)again.
[Rev.8 from Aug 2018] 2026.04.04 04:31:27 UTC