L/G SYS DISAGREE With No LGCIU BITE Message
TASK 32-31-00-810-888-A
L/G SYS DISAGREE With No LGCIU BITE Message
A. Referenced Information
3. Fault Confirmation
Subtask 32-31-00-710-077-A
Subtask 32-31-00-865-065-A
[Rev.8 from Aug 2018]
2026.04.04 04:31:27 UTC
L/G SYS DISAGREE With No LGCIU BITE Message
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Possible Causes- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
- PROX SNSR-NLG DOORS CLOSED, SYS 1 [30GA]
- PROX SNSR-L L/G DOOR CLOSED, SYS 1 [27GA]
- PROX SNSR-R L/G DOOR CLOSED, SYS 1 [26GA]
- UPLOCK ASSY-NLG DOOR [2534GM]
- UPLOCK ASSY-MLG DOOR, R [2520GM]
- UPLOCK ASSY-MLG DOOR, L [2521GM]
- PROX SNSR-NLG DOORS CLOSED, SYS 2 [31GA]
- PROX SNSR-L L/G DOOR CLOSED, SYS 2 [29GA]
- PROX SNSR-R L/G DOOR CLOSED, SYS 2 [28GA]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-32-00-860-009 | Procedure to Get Access to the SYSTEM REPORT/TEST/L/G Page |
| AMM 32-00-00-860-001 | Flight Configuration Precautions with Electrical Power |
| AMM 32-31-14-000-001 | Removal of the NLG Door Uplock Assy |
| AMM 32-31-14-400-001 | Installation of the NLG Door Uplock Assy |
| AMM 32-31-33-000-001 | Removal of the MLG Door Uplock 2520GM |
| AMM 32-31-33-400-002 | Installation of the MLG Door Uplock 2520GM |
| AMM 32-31-73-000-001 | Removal of the MLG Proximity-Sensors |
| AMM 32-31-73-000-005 | Removal of the NLG Proximity-Sensors |
| AMM 32-31-73-400-001 | Installation of the MLG Proximity-Sensors |
| AMM 32-31-73-400-005 | Installation of the NLG Proximity-Sensors |
| AMM 32-31-73-820-008 | Inductance Check of the Proximity Sensors/Switches |
Subtask 32-31-00-710-077-A
A. Test
(1) Before the L/G doors are opened for maintenance:
(a) Get access to the L/G SYSTEM/REPORT/TEST L/G page AMM 31-32-00-860-009.
(b) Do a check of the LAST LEG REPORT and the GROUND SCANNING of LGCIU 1 and 2.
(c) If a fault message is shown do the applicable troubleshooting procedure.
(a) Do the trouble shooting from Para. 4.
4. Fault Isolation(1) Before the L/G doors are opened for maintenance:
(a) Get access to the L/G SYSTEM/REPORT/TEST L/G page AMM 31-32-00-860-009.
(b) Do a check of the LAST LEG REPORT and the GROUND SCANNING of LGCIU 1 and 2.
(c) If a fault message is shown do the applicable troubleshooting procedure.
NOTE: If the L/G doors are opened for maintenance before you get access to the LGCIU LAST LEG REPORT and the GROUND SCANNING. A message unrelated to the defect will be shown.
NOTE: The ECAM WARNING "L/G SYS DISAGREE" is inhibited during flight phases, 03, 04, 05, 07 and 08.
(2) If no maintenance message is shown: (a) Do the trouble shooting from Para. 4.
Subtask 32-31-00-865-065-A
A. Table of the circuit breakers used in this procedure:
Subtask 32-31-00-810-150-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | L/G/LGCIU/SYS1/NORM | 1GA | C09 |
| 121VU | HYDRAULIC/LGCIU/SYS2 | 2GA | Q35 |
| 121VU | HYDRAULIC/LGCIU/SYS1/GRND SPLY | 52GA | Q34 |
B. Procedure
(1) Make sure that all the L/G doors are in the closed position.
(2) Do the flight configuration precautions, AMM 32-00-00-860-001, make sure the aircraft has ground electrical power.
(3) To put LGCIU 1 in control:
(a) Make sure C/B's 1GA and 52GA are closed and open the C/B 2GA.
(b) On the ECAM WHEEL PAGE make sure that the L/G door indication shows all the doors closed.
(4) If the L/G door indication is correct, go to step (12).
(5) If a L/G door indication does not show closed:
(a) Do an inductance test of the applicable proximity sensor AMM 32-31-73-820-008:
(7) If a defect is found, replace the applicable proximity sensor:
(9) If the fault continues:
(a) Replace the applicable uplock:
(11) Close the C/B 2GA.
(12) To troubleshoot System 2:
(a) Make sure that all the L/G doors are in the closed position.
(b) Do the flight configuration precautions, AMM 32-00-00-860-001, make sure the aircraft has electrical power.
(13) To put LGCIU 2 in control:
(a) Make sure C/B 2GA is closed and open the C/B's 1GA and 52GA.
(b) On the ECAM WHEEL PAGE make sure that the L/G door indication shows all the doors closed.
(14) If a L/G door indication does not show closed:
(a) Do an inductance test of the applicable proximity sensor AMM 32-31-73-820-008:
(17) If the fault continues:
(a) Replace the applicable uplock:
(1) Make sure that all the L/G doors are in the closed position.
(2) Do the flight configuration precautions, AMM 32-00-00-860-001, make sure the aircraft has ground electrical power.
(3) To put LGCIU 1 in control:
(a) Make sure C/B's 1GA and 52GA are closed and open the C/B 2GA.
(b) On the ECAM WHEEL PAGE make sure that the L/G door indication shows all the doors closed.
(4) If the L/G door indication is correct, go to step (12).
(5) If a L/G door indication does not show closed:
(a) Do an inductance test of the applicable proximity sensor AMM 32-31-73-820-008:
- for the NLG door PROX SNSR-NLG DOORS CLOSED, SYS 1 [30GA]
- for the L MLG door PROX SNSR-L L/G DOOR CLOSED, SYS 1 [27GA]
- for the R MLG door PROX SNSR-R L/G DOOR CLOSED, SYS 1 [26GA] .
(7) If a defect is found, replace the applicable proximity sensor:
- for a NLG door proximity sensor AMM 32-31-73-000-005 and AMM 32-31-73-400-005
- for a MLG door proximity sensor AMM 32-31-73-000-001 and AMM 32-31-73-400-001.
(9) If the fault continues:
(a) Replace the applicable uplock:
- for UPLOCK ASSY-NLG DOOR [2534GM] , AMM 32-31-14-000-001 and AMM 32-31-14-400-001
- for UPLOCK ASSY-MLG DOOR, R [2520GM] or UPLOCK ASSY-MLG DOOR, L [2521GM] , AMM 32-31-33-000-001 and AMM 32-31-33-400-002.
(11) Close the C/B 2GA.
(12) To troubleshoot System 2:
(a) Make sure that all the L/G doors are in the closed position.
(b) Do the flight configuration precautions, AMM 32-00-00-860-001, make sure the aircraft has electrical power.
(13) To put LGCIU 2 in control:
(a) Make sure C/B 2GA is closed and open the C/B's 1GA and 52GA.
(b) On the ECAM WHEEL PAGE make sure that the L/G door indication shows all the doors closed.
(14) If a L/G door indication does not show closed:
(a) Do an inductance test of the applicable proximity sensor AMM 32-31-73-820-008:
- for the NLG door PROX SNSR-NLG DOORS CLOSED, SYS 2 [31GA]
- for the L MLG door PROX SNSR-L L/G DOOR CLOSED, SYS 2 [29GA]
- for the R MLG door PROX SNSR-R L/G DOOR CLOSED, SYS 2 [28GA] .
- for a NLG door proximity sensor AMM 32-31-73-000-005 and AMM 32-31-73-400-005
- for a MLG door proximity sensor AMM 32-31-73-000-001 and AMM 32-31-73-400-001.
(17) If the fault continues:
(a) Replace the applicable uplock:
- for UPLOCK ASSY-NLG DOOR [2534GM] , AMM 32-31-14-000-001 and AMM 32-31-14-400-001
- for UPLOCK ASSY-MLG DOOR, R [2520GM] or UPLOCK ASSY-MLG DOOR, L [2521GM] , AMM 32-31-33-000-001 and AMM 32-31-33-400-002.