LGCIU 1 (2) Fault
TASK 32-31-00-810-872-A
LGCIU 1 (2) Fault
A. Referenced Information
3. Fault Confirmation
Subtask 32-31-00-740-083-A
Subtask 32-31-00-865-066-A
[Rev.8 from Aug 2018]
2026.04.04 04:31:25 UTC
LGCIU 1 (2) Fault
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. MOVEMENT OF THE LANDING GEAR CAN CAUSE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
1. Possible Causes- LGCIU
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 32-31-00-810-839-A | LGCIU BITE Test Not Possible |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 29-10-00-864-001 | Depressurize the Green Hydraulic System |
| AMM 31-32-00-860-009 | Procedure to Get Access to the SYSTEM REPORT/TEST/L/G Page |
Subtask 32-31-00-740-083-A
A. Test
(1) Get access to the SYSTEM REPORT/TEST/L/G page AMM 31-32-00-860-009:
(a) If you cannot get access to the SYSTEM REPORT/TEST/L/G page:
(3) If there are fault codes shown, do the applicable trouble shooting procedure, (Ref. P. Block 301).
(4) If there are no fault codes shown, and the LGCIU 2 ECAM WARNING is shown:
(a) Do the procedure in Para. 4. B. to do a reset of the LGCIU 2.
4. Fault Isolation(1) Get access to the SYSTEM REPORT/TEST/L/G page AMM 31-32-00-860-009:
(a) If you cannot get access to the SYSTEM REPORT/TEST/L/G page:
- Make sure that the aircraft electrical circuits are energized with an external power supply AMM 24-41-00-861-002. If external power is not available, do the TSM procedure 'LGCIU BITE Test Not Possible' (Ref. TSM TASK 32-31-00-810-839).
(3) If there are fault codes shown, do the applicable trouble shooting procedure, (Ref. P. Block 301).
(4) If there are no fault codes shown, and the LGCIU 2 ECAM WARNING is shown:
(a) Do the procedure in Para. 4. B. to do a reset of the LGCIU 2.
NOTE: If the LGCIU 2 FAULT shows after a L/G free fall test, with no other fault codes, you can ignore the fault.
Subtask 32-31-00-865-066-A
A. Table of the circuit breakers used in this procedure:
Subtask 32-31-00-810-130-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | HYDRAULIC/LGCIU/SYS2 | 2GA | Q35 |
B. Procedure
(1) Do a reset of the LGCIU-2 as follows:
(a) Make sure that the green hydraulic system is depressurised AMM 29-10-00-864-001.
(b) Open C/B 2GA.
(c) Wait for a minimum of 15 seconds.
(d) Close C/B 2GA.
(e) Make sure that the ECAM WARNING has gone.
(1) Do a reset of the LGCIU-2 as follows:
(a) Make sure that the green hydraulic system is depressurised AMM 29-10-00-864-001.
(b) Open C/B 2GA.
(c) Wait for a minimum of 15 seconds.
(d) Close C/B 2GA.
(e) Make sure that the ECAM WARNING has gone.