LLG Downlock Proximity Sensor Fault
TASK 32-31-00-810-823-A
LLG Downlock Proximity Sensor Fault
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 32-31-00-740-063-A
Subtask 32-31-00-810-074-A
Subtask 32-31-00-860-073-A
[Rev.8 from Aug 2018]
2026.04.04 04:31:20 UTC
LLG Downlock Proximity Sensor Fault
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. MOVEMENT OF THE LANDING GEAR CAN CAUSE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Possible Causes- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
- PROX SNSR-L L/G DNLK, SYS 1 [15GA]
- PROX SNSR-L L/G DNLK, SYS 2 [17GA]
- wiring
- LGCIU-1 [5GA1]
- LGCIU-2 [5GA2]
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | INDUCTANCE METER 1KHZ |
| No specific | AR | MULTIMETER - STANDARD |
| No specific | AR | TESTER - INSULATION RESISTANCE |
| 38-368-02 | 1 | UNIT-TEST,SENSOR |
| 38-368-03 | 1 | UNIT-TEST,SENSOR |
| REFERENCE | DESIGNATION |
|---|---|
| AMM 32-31-00-040-003 | Check of the System 2 Proximity Sensors of the Landing Gear and the Landing Gear Doors |
| ASM 323103 | |
| ASM 323104 | |
| AMM 32-31-71-000-001 | Removal of the LGCIU |
| AMM 32-31-71-400-001 | Installation of the LGCIU |
| AMM 32-31-73-000-001 | Removal of the MLG Proximity-Sensors |
| AMM 32-31-73-200-001 | Inspection of the MLG Proximity Sensor and Target Clearances |
| AMM 32-31-73-400-001 | Installation of the MLG Proximity-Sensors |
| AMM 32-31-73-820-008 | Inductance Check of the Proximity Sensors/Switches |
| AMM 32-69-00-740-001 | BITE Check of Landing-Gear Control Interface-Unit (LGCIU) With Use of MCDU to Ensure that Continuous BITE is Operative |
| TSM TASK 32-31-00-03 | NORMAL EXTENSION AND RETRACTION - TASK SUPPORTING DATA |
Subtask 32-31-00-740-063-A
A. Test
(1) Do a BITE test on the LGCIU 1 or LGCIU 2 AMM 32-69-00-740-001, which identified the L L/G proximity-sensor fault:
4. Fault Isolation(1) Do a BITE test on the LGCIU 1 or LGCIU 2 AMM 32-69-00-740-001, which identified the L L/G proximity-sensor fault:
- If a L L/G DNLK PROX SNSR message is shown, do the isolation procedure in Para. 4.A.(2).
NOTE: The fault L L/G DNLK PROX SNSR TGT POS can not be identified by the BITE test. The BITE test can only confirm an open-circuit or short-circuit in the proximity-sensor, or its related wiring. Target position faults can only be confirmed by continuous BITE during L/G operation. To confirm a target position fault, it is necessary to do the proximity-sensor/target inspection and the inductance check, given in the fault isolation procedure.
Subtask 32-31-00-810-074-A
A. Procedure
(1) If the PRF shows a proximity sensor target-position fault, do the steps that follow:
(a) Do the inspection of the PROX SNSR-L L/G DNLK, SYS 1 [15GA] or the PROX SNSR-L L/G DNLK, SYS 2 [17GA] AMM 32-31-73-200-001.
(b) Use the INDUCTANCE METER 1KHZ to do a check of the inductance of the applicable proximity sensor AMM 32-31-73-820-008:
(a) At the applicable proximity sensor, release the electrical-connector.
(b) If the 38-368-02 UNIT-TEST,SENSOR or the 38-368-03 UNIT-TEST,SENSOR is available, do the troubleshooting procedure of the proximity sensor32-31-00-03 TSM TASK 32-31-00-03 .
(c) Use the MULTIMETER - STANDARD and do a check of the resistance between pins A and B of the proximity sensors, ASM 323103 or ASM 323104. Make sure that the resistance is:
(e) Connect one test lead of the TESTER - INSULATION RESISTANCE to pins AB and the other test lead to the case.
(f) Supply a test signal for five seconds and read the resistance value shown.
(g) Make sure that the resistance is more than 400 Megohms.
(h) From the resistance checks in steps (c) and (g):
(4) Do a check and repair the wiring between the applicable proximity sensor electrical-connector and the related LGCIU ARINC tray, ASM 323103 or ASM 323104.
(5) Do the test in Para. 3.A. (1).
(7) If MMEL conditions apply to the PROX SNSR-L L/G DNLK, SYS 2 [17GA] :
(a) Do the deactivation procedure of the proximity sensor AMM 32-31-00-040-003.
5. Close-up(1) If the PRF shows a proximity sensor target-position fault, do the steps that follow:
(a) Do the inspection of the PROX SNSR-L L/G DNLK, SYS 1 [15GA] or the PROX SNSR-L L/G DNLK, SYS 2 [17GA] AMM 32-31-73-200-001.
(b) Use the INDUCTANCE METER 1KHZ to do a check of the inductance of the applicable proximity sensor AMM 32-31-73-820-008:
- If the fault continues, do step (2).
(a) At the applicable proximity sensor, release the electrical-connector.
(b) If the 38-368-02 UNIT-TEST,SENSOR or the 38-368-03 UNIT-TEST,SENSOR is available, do the troubleshooting procedure of the proximity sensor
(c) Use the MULTIMETER - STANDARD and do a check of the resistance between pins A and B of the proximity sensors, ASM 323103 or ASM 323104. Make sure that the resistance is:
- Between 11 and 13 ohms for a ferrite proximity sensor (PN 8-484-01)
- Between 15 and 17 ohms for an all metal proximity sensor (PN 8-933-01).
(e) Connect one test lead of the TESTER - INSULATION RESISTANCE to pins AB and the other test lead to the case.
(f) Supply a test signal for five seconds and read the resistance value shown.
(g) Make sure that the resistance is more than 400 Megohms.
(h) From the resistance checks in steps (c) and (g):
- If the two resistance values are correct, do step (4)
- If one or more of the resistance values is not correct, do the next step.
(4) Do a check and repair the wiring between the applicable proximity sensor electrical-connector and the related LGCIU ARINC tray, ASM 323103 or ASM 323104.
(5) Do the test in Para. 3.A. (1).
- If the fault continues, do step (6).
(7) If MMEL conditions apply to the PROX SNSR-L L/G DNLK, SYS 2 [17GA] :
(a) Do the deactivation procedure of the proximity sensor AMM 32-31-00-040-003.
Subtask 32-31-00-860-073-A
A. Put the aircraft back to its initial configuration.