FWD Cargo Door LGCIU 2 Control Fault
TASK 32-31-00-810-899-A
FWD Cargo Door LGCIU 2 Control Fault
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 32-31-00-700-060-A
Subtask 32-31-00-810-163-A
[Rev.8 from Aug 2018]
2026.04.04 04:31:29 UTC
FWD Cargo Door LGCIU 2 Control Fault
WARNING:
MAKE SURE THAT THE TRAVEL RANGE OF THE CARGO DOOR IS CLEAR BEFORE YOU UNLOCK IT. STAY AFT OF (LEFT OF) THE DOOR WHEN YOU UNLOCK IT BECAUSE IT CAN OPEN SUDDENLY AND CAUSE INJURY.
CAUTION:
DO NOT OPEN THE CARGO COMPARTMENT DOORS IF THE WIND SPEED IS MORE THAN 40 KNOTS TO PREVENT DAMAGE TO THE DOOR OR TO THE AIRCRAFT STRUCTURE.
CAUTION:
YOU MUST CLOSE THE CARGO COMPARTMENT DOORS BEFORE THE WIND SPEED IS MORE THE 65 KNOTS TO PREVENT DAMAGE TO THE DOOR OR TO THE AIRCRAFT STRUCTURE.
1. Possible Causes2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 32-31-71-000-001 | Removal of the LGCIU |
| AMM 32-31-71-400-001 | Installation of the LGCIU |
| AMM 52-30-00-860-001 | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| AMM 52-30-00-860-002 | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| AMM 52-30-00-860-003 | Open the FWD or Aft Cargo-Compartment Door with the Hand Pump |
| ASM 523501 | |
| AMM 52-36-15-000-001 | Removal of the Manual Selector Valve |
| AMM 52-36-15-400-001 | Installation of the Manual Selector Valve |
Subtask 32-31-00-700-060-A
A. Test
(1) If the CFDS message LGCIU2(5GA2)/WRG: AA7A is shown (for the FWD cargo door) on the PFR and the FWD cargo door operates correctly:
(a) No maintenance steps are necessary.
(2) If the FWD cargo door does not operate correctly:
(a) Do the fault isolation.
4. Fault Isolation(1) If the CFDS message LGCIU2(5GA2)/WRG: AA7A is shown (for the FWD cargo door) on the PFR and the FWD cargo door operates correctly:
(a) No maintenance steps are necessary.
(2) If the FWD cargo door does not operate correctly:
(a) Do the fault isolation.
Subtask 32-31-00-810-163-A
A. Procedure
(1) Remove the LGCIU-2 [5GA2] AMM 32-31-71-000-001.
(3) Set the FWD cargo door manual selector to open and hold:
(a) Replace the MAN SEL VALVE-FWD CARGO DOOR [2501MJ] , AMM 52-36-15-000-001 and AMM 52-36-15-400-001.
(b) Install the LGCIU-2 [5GA2] , AMM 32-31-71-400-001.
(6) Open and close the FWD cargo door AMM 52-30-00-860-001 and AMM 52-30-00-860-002.
(7) If no defect was found in step (3) or the fault continues:
(a) Replace the LGCIU-2 [5GA2] , AMM 32-31-71-000-001 and AMM 32-31-71-400-001.
(8) Do the test in step (6).
(9) If the fault continues:
(a) Do the trouble shooting of the FWD cargo door Ref. TSM ATA 52-30-00.
(1) Remove the LGCIU-2 [5GA2] AMM 32-31-71-000-001.
WARNING:
MAKE SURE THAT THE TRAVEL RANGE OF THE CARGO DOOR IS CLEAR BEFORE YOU UNLOCK IT. STAY AFT OF (LEFT OF) THE DOOR WHEN YOU UNLOCK IT BECAUSE IT CAN OPEN SUDDENLY AND CAUSE INJURY.
(2) Open the FWD cargo door AMM 52-30-00-860-003 but do not open safety and tag the C/B (1MJ): NOTE: Removal of the LGCIU 2 prevents operation of the Yellow Electric Pump.
(a) Let the door open with gravity only. Do not use force. (3) Set the FWD cargo door manual selector to open and hold:
NOTE: The cargo door can move with the manual selector set to open.
(a) At the LGCIU 2 ARINC tray: - Do a check at pin AA7A, 28VDC must be available.
- There must be no 28VDC on pin AA7A.
- There must be 28VDC available on pin AA7A.
- LGCIU 2 (5GA2) Pin AA7A to the SW-VALVE FWD SELECTOR 2501MJ Pin AB
- ASM 523501.
(a) Replace the MAN SEL VALVE-FWD CARGO DOOR [2501MJ] , AMM 52-36-15-000-001 and AMM 52-36-15-400-001.
(b) Install the LGCIU-2 [5GA2] , AMM 32-31-71-400-001.
(6) Open and close the FWD cargo door AMM 52-30-00-860-001 and AMM 52-30-00-860-002.
(7) If no defect was found in step (3) or the fault continues:
(a) Replace the LGCIU-2 [5GA2] , AMM 32-31-71-000-001 and AMM 32-31-71-400-001.
(8) Do the test in step (6).
(9) If the fault continues:
(a) Do the trouble shooting of the FWD cargo door Ref. TSM ATA 52-30-00.