W DOC AIRBUS | TSM A320F

L/G - Gear Selector Valve or Door Selector Valve Fault


TASK 32-31-00-810-883-A
L/G - Gear Selector Valve or Door Selector Valve Fault


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 32-31-00-810-806-A
L/G Selector Valve Fault
TSM TASK 32-31-00-810-807-A
L/G Doors Selector Valve System Fault
3. Fault Confirmation
Subtask 32-31-00-710-074-A
A. Test
   (1) Do a BITE test of the LGCIU-1 [5GA1] or LGCIU-2 [5GA2] identified on the Post Flight Report (PFR):
  • if the message LGCIU1(2)/VALVES 40GA/41GA is shown, do the fault isolation procedure in Para. 4.A.
  • if a different message is shown, do the trouble shooting procedure related to the maintenance message.
4. Fault Isolation
Subtask 32-31-00-810-141-A
A. Procedure
   (1) Do the fault isolation procedure for the [40GA] (Ref. TSM TASK 32-31-00-810-806).
     (a) Do the test in Para. 3.A.:
  • if the fault continues, do the next step.
   (2) Do the fault isolation procedure for the [41GA] (Ref. TSM TASK 32-31-00-810-807).
     (a) Do the test in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:31:26 UTC