36-12 APU BLEED AIR SUPPLY AND CROSSBLEED SYSTEMS
- PB.001 APU BLEED AIR SUPPLY AND CROSSBLEED SYSTEMS - DESCRIPTION AND OPERATION
- PB.001 CONF:[21] APU BLEED AIR SUPPLY AND CROSSBLEED SYSTEMS - DESCRIPTION AND OPERATION
- PB.001 CONF:[03] APU BLEED AIR SUPPLY AND CROSSBLEED SYSTEMS - DESCRIPTION AND OPERATION
- PB.201 APU BLEED AIR SUPPLY AND CROSSBLEED SYSTEMS - MAINTENANCE PRACTICES
-
36-12-00-615-804-A
[10]
Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA1,4000HA2) with the APU Bleed Pressure -
36-12-00-615-804-A-01
[10]
Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA1) with the APU Bleed Pressure -
36-12-00-615-804-A-02
[10]
Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA2) with the APU Bleed Pressure -
36-12-00-615-807-A
[10]
Decontamination of the Bleed-Air Ducting System Disconnected at HP Ground Connector with the APU Bleed Pressure -
36-12-00-860-001-A
[10]
Pressurization of the Bleed System with the APU -
36-12-00-860-002-A
[10]
Pressurization of the Bleed System through the HP Ground Connector -
36-12-00-615-802-A
[10]
Decontamination of the Bleed-Air Ducting System Disconnected at APU Load-Compressor Valve with Engine 1 Bleed Pressure -
36-12-00-615-802-A-01
[10]
Decontamination of the Bleed-Air Ducting System Disconnected at APU Load-Compressor Valve with Engine 2 Bleed Pressure -
36-12-00-615-802-A-02
[10]
Decontamination of the Bleed-Air Ducting System Disconnected at APU Load-Compressor Valve with Engine 2 Bleed Pressure -
36-12-00-615-802-A-03
[10]
Decontamination of the Bleed-Air Ducting System Disconnected at APU Load-Compressor Valve with Engine 1 Bleed Pressure
-
36-12-00-615-804-A
[10]
- PB.201 CONF:[21] APU BLEED AIR SUPPLY AND CROSSBLEED SYSTEMS - MAINTENANCE PRACTICES
-
36-12-00-615-806-A
[10]
Decontamination of the Bleed-Air Ducting System disconnected at the Pressure Regulating Valve (PRV) (4000HA1, 4000HA2) with the APU Bleed Pressure -
36-12-00-615-806-A-01
[10]
Decontamination of the Bleed-Air Ducting System disconnected at the Pressure Regulating Valve (PRV) (4000HA1) with the APU Bleed Pressure -
36-12-00-615-806-A-02
[10]
Decontamination of the Bleed-Air Ducting System disconnected at the Pressure Regulating Valve (PRV) (4000HA2) with the APU Bleed Pressure -
36-12-00-615-808-A
[10]
Decontamination of the Bleed-Air Ducting System Disconnected at HP Ground Connector with the APU Bleed Pressure -
36-12-00-860-802-A
[10]
Pressurization of the Bleed System with the APU -
36-12-00-860-803-A
[10]
Pressurization of the Bleed System through the HP Ground Connector -
36-12-00-860-804-A
[10]
Pressurization of the Bleed System from a Second Aircraft -
36-12-00-615-803-A
[10]
Decontamination of the Bleed-Air Ducting System Disconnected at the APU Load-Compressor Valve with Engine 1 Bleed Pressure -
36-12-00-615-803-A-01
[10]
Decontamination of the Bleed-Air Ducting System Disconnected at the APU Load-Compressor Valve with Engine 2 Bleed Pressure
-
36-12-00-615-806-A
[10]
- PB.201 CONF:[03] APU BLEED AIR SUPPLY AND CROSSBLEED SYSTEMS - MAINTENANCE PRACTICES
-
36-12-00-615-805-A
[10]
Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA1, 4000HA2) with the APU Bleed Pressure -
36-12-00-615-805-A-01
[10]
Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA1) with the APU Bleed Pressure -
36-12-00-615-805-A-02
[10]
Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA2) with the APU Bleed Pressure -
36-12-00-615-809-A
[10]
Decontamination of the Bleed-Air Ducting System through HP Ground Connector with the APU Bleed Pressure -
36-12-00-860-805-A
[10]
Pressurization of the Bleed System with the APU -
36-12-00-860-806-A
[10]
Pressurization of the Bleed System through the HP Ground Connector -
36-12-00-615-801-A
[10]
Decontamination of the Bleed-Air Ducting System Disconnected at APU Load-Compressor Valve with Engine 1 Bleed Pressure -
36-12-00-615-801-A-01
[10]
Decontamination of the Bleed-Air Ducting System Disconnected at APU Load-Compressor Valve with Engine 2 Bleed Pressure
-
36-12-00-615-805-A
[10]
- PB.401 APU BLEED AIR SUPPLY AND CROSSBLEED SYSTEMS - DEACTIVATION/REACTIVATION
-
36-12-00-040-808-A
[10]
Deactivation of the APU Leak-Detection Loop -
36-12-00-040-810-A
[10]
Deactivation of the APU Leak-Detection Loop -
36-12-00-040-811-A
[10]
Deactivation of the APU Leak-Detection Loop -
36-12-00-440-805-A
[10]
Reactivation of the APU Leak-Detection Loop -
36-12-00-440-807-A
[10]
Reactivation of the APU Leak-Detection Loop -
36-12-00-440-808-A
[10]
Reactivation of the APU Leak-Detection Loop -
36-12-00-040-801-A
[10]
Deactivation of the APU Bleed Check-Valve -
36-12-00-040-804-A
[10]
Inspection of the APU Bleed Check-Valve for Correct Condition -
36-12-00-440-801-A
[10]
Reactivation of the APU Bleed Check-Valve
-
36-12-00-040-808-A
[10]
- PB.401 CONF:[21] APU BLEED AIR SUPPLY AND CROSSBLEED SYSTEMS - DEACTIVATION/REACTIVATION
-
36-12-00-040-813-A
[10]
Deactivation of the APU Leak-Detection Loop -
36-12-00-040-815-A
[10]
Deactivation of the APU Leak-Detection Loop -
36-12-00-040-820-A
[10]
Deactivation of the APU Leak-Detection Loop -
36-12-00-440-813-A
[10]
Reactivation of the APU Leak-Detection Loop -
36-12-00-440-815-A
[10]
Reactivation of the APU Leak-Detection Loop -
36-12-00-440-820-A
[10]
Reactivation of the APU Leak-Detection Loop -
36-12-00-040-802-A
[10]
Deactivation of the APU Bleed Check-Valve -
36-12-00-440-802-A
[10]
Reactivation of the APU Bleed Check-Valve -
36-12-00-040-805-A
[10]
Inspection of the APU Bleed Check-Valve for Correct Condition
-
36-12-00-040-813-A
[10]
- PB.401 CONF:[03] APU BLEED AIR SUPPLY AND CROSSBLEED SYSTEMS - DEACTIVATION/REACTIVATION
-
36-12-00-040-814-A
[10]
Deactivation of the APU Leak-Detection Loop -
36-12-00-040-819-A
[10]
Deactivation of the APU Leak-Detection Loop -
36-12-00-040-821-A
[10]
Deactivation of the APU Leak-Detection Loop -
36-12-00-440-814-A
[10]
Reactivation of the APU Leak-Detection Loop -
36-12-00-440-819-A
[10]
Reactivation of the APU Leak-Detection Loop -
36-12-00-440-821-A
[10]
Reactivation of the APU Leak-Detection Loop -
36-12-00-040-803-A
[10]
Deactivation of the APU Bleed Check-Valve -
36-12-00-440-803-A
[10]
Reactivation of the APU Bleed Check-Valve -
36-12-00-040-806-A
[10]
Inspection of the APU Bleed Check-Valve for Correct Condition
-
36-12-00-040-814-A
[10]
- PB.501 APU BLEED AIR SUPPLY AND CROSSBLEED SYSTEMS - ADJUSTMENT/TEST
-
36-12-00-710-001-A
[10]
Operational Test of the APU Bleed Air Supply and Crossbleed Systems -
36-12-00-710-002-A
[10]
Operational Check of Crossbleed Valve in Manual Mode -
36-12-00-790-001-A
[10]
Leak Test of the APU Bleed-Air Supply-System -
36-12-00-790-002-A
[10]
Perform Leak Check on APU Bleed Air Ducting (Upstream the APU Bleed Check Valve) -
36-12-00-790-003-A
[10]
Leak Check of Bleed Air Ducting in the Fuselage Area between the APU Bleed Check Valve, Air Conditioning Pack and Wing/Fuselage Connection
-
36-12-00-710-001-A
[10]
- PB.401 SPRING ROD - REMOVAL/INSTALLATION
-
36-12-11-000-001-A
[10]
Removal of the Spring Rods (FR65, FR68, FR72, FR74 and FR80) -
36-12-11-400-001-A
[10]
Installation of the Spring Rods (FR65, FR68, FR72 , FR74 and FR80)
-
36-12-11-000-001-A
[10]
- PB.401 DUCT - APU AND CROSSBLEED AIR SUPPLY SYSTEM - REMOVAL/INSTALLATION
-
36-12-41-000-001-A
[10]
Removal of a Bleed-Air Duct -
36-12-41-400-001-A
[10]
Installation of a Bleed-Air Duct
-
36-12-41-000-001-A
[10]
- PB.401 BELLOWS, FR 70 TO FR71 - REMOVAL/INSTALLATION
-
36-12-42-000-001-A
[10]
Removal of the Bellows -
36-12-42-400-001-A
[10]
Installation of the Bellows
-
36-12-42-000-001-A
[10]
- PB.401 VALVE - APU BLEED CHECK - REMOVAL/INSTALLATION
-
36-12-51-000-001-A
[10]
Removal of the APU Bleed Check-Valve -
36-12-51-400-001-A
[10]
Installation of the APU Bleed Check-Valve -
36-12-51-000-002-A
[10]
Removal of the Assembly of the APU Bleed Check-Valve -
36-12-51-400-002-A
[10]
Installation of the Assembly of the APU Bleed Check-Valve
-
36-12-51-000-001-A
[10]
- PB.601 VALVE - APU BLEED CHECK - INSPECTION/CHECK
-
36-12-51-200-001-A
[10]
Remove and Check the Auxiliary Power Unit (APU) Bleed Check-Valve for Condition
-
36-12-51-200-001-A
[10]
- PB.401 VALVE - CROSSBLEED - REMOVAL/INSTALLATION
-
36-12-52-000-001-A
[10]
Removal of the Crossbleed Valve -
36-12-52-400-001-A
[10]
Installation of the Crossbleed Valve -
36-12-52-000-002-A
[10]
Removal of the Crossbleed Valve Actuator -
36-12-52-400-002-A
[10]
Installation of the Crossbleed Valve Actuator
-
36-12-52-000-001-A
[10]
- PB.601 VALVE - CROSSBLEED - INSPECTION/CHECK
-
36-12-52-200-001-A
[10]
Inspection of the Crossbleed Valve
-
36-12-52-200-001-A
[10]
- PB.601 CONF:[21] VALVE - CROSSBLEED - INSPECTION/CHECK
-
36-12-52-200-802-A
[10]
Inspection of the Crossbleed Valve
-
36-12-52-200-802-A
[10]
- PB.601 CONF:[03] VALVE - CROSSBLEED - INSPECTION/CHECK
-
36-12-52-200-803-A
[10]
Inspection of the Crossbleed Valve
-
36-12-52-200-803-A
[10]