Deactivation of the APU Leak-Detection Loop


TASK 36-12-00-040-811-A
Deactivation of the APU Leak-Detection Loop


WARNING: MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
ZONE: 191
ZONE: 211
1. Reason for the Job
MMEL 36-09-01E
AIR APU BLEED LEAK ALERT
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
191
AIR CONDITIONING COMPT AND FAIRINGS
211
COCKPIT
191DB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 36-11-00-740-001-A
BITE Test of the BMC 1(2)
TASK 36-12-51-200-001-A
Remove and Check the Auxiliary Power Unit (APU) Bleed Check-Valve for Condition
TASK 36-22-00-790-001-A
Leak Check on all the Bleed Air Ducts and the Packs Components
AWM 362201
3. Job Set-up
Subtask 36-12-00-861-054-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 36-12-00-941-081-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) In the cockpit, on AIR COND panel 25VU:
     (a) Make sure that the ENG BLEED 1 and 2 pushbutton switches are released (the OFF legends are on).
     (b) Make sure that the APU BLEED pushbutton switch is released (the ON legend is off).
     (c) Make sure that the PACK 1 and 2 pushbutton switches are released (the OFF legends are on).
     (d) Make sure that the X BLEED selector switch is set to the OFF position.
     (e) Put a WARNING NOTICE(S) in position to tell persons not to operate the ENG BLEED 1 and 2 pushbutton switches.
     (f) Put the WARNING NOTICE(S) in position to tell persons not to operate the APU BLEED system.
   (2) Open access door 191DB on the HP ground connector:
     (a) Put the WARNING NOTICE(S) in position to tell persons not to pressurize the pneumatic system.
4. Procedure
Subtask 36-12-00-740-052-A ** ON A/C NOT FOR ALL
A. BITE Test
   (1) Do the BITE test of BMC 1(2) (Ref. AMM TASK 36-11-00-740-001):
     (a) Make sure that the fault "36-22-17 - APU LOOP" comes into view.
Subtask 36-12-00-790-072-A ** ON A/C NOT FOR ALL
B. Leak Test
   (1) Do a leak check of the APU bleed-air ducts (Ref. AMM TASK 36-22-00-790-001):
     (a) Make sure that there are no leaks.
NOTE: A leak on the APU bleed-air ducts is a NO GO condition.
Subtask 36-12-00-865-161-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR BLEED/X FEED/VALVE/BAT2HVD13
49VUAIR BLEED/ENG 1/CTL3HA1D12
49VUAIR BLEED/ENG 1/MONG2HA1D11
122VUAIR BLEED/ENG 2/CTL3HA2Z23
122VUAIR BLEED/ENG 2/MONG2HA2Z22
122VUAIR BLEED/X FEED VALVE/NORM1HVZ20
Subtask 36-12-00-040-059-A ** ON A/C NOT FOR ALL
D. Deactivation of the APU Leak-Detection Loops
   (1) On lower-right connector-plate 95VU, do the steps that follow:
     (a) Remove connector 251VC-A from its location.
     (b) Disconnect pins 25 and 26 from connector 251VC-A and put the CAP - BLANKING on the pins to prevent them from contamination AWM 362201.
     (c) Identify the disconnected cables with a label.
     (d) Install connector 251VC-A on the plate.
Subtask 36-12-00-220-062-A ** ON A/C NOT FOR ALL
E. Inspection of the APU Bleed Check-Valve
   (1) Make sure that the APU bleed check-valve is serviceable (Ref. AMM TASK 36-12-51-200-001).
NOTE: An unserviceable APU bleed check-valve is a NO GO condition.
Subtask 36-12-00-865-162-A ** ON A/C NOT FOR ALL
F. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR BLEED/X FEED/VALVE/BAT2HVD13
49VUAIR BLEED/ENG 1/CTL3HA1D12
49VUAIR BLEED/ENG 1/MONG2HA1D11
122VUAIR BLEED/ENG 2/CTL3HA2Z23
122VUAIR BLEED/ENG 2/MONG2HA2Z22
122VUAIR BLEED/X FEED VALVE/NORM1HVZ20
5. Close-up
Subtask 36-12-00-860-150-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the WARNING NOTICE(S).
   (3) Close access door 191DB.
   (4) Make an entry in the logbook.
Subtask 36-12-00-862-053-A ** ON A/C NOT FOR ALL
B. De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).