Pressurization of the Bleed System with the APU
TASK 36-12-00-860-001-A
Pressurization of the Bleed System with the APU
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 36-12-00-941-051-A ** ON A/C NOT FOR ALL
Subtask 36-12-00-869-055-B ** ON A/C NOT FOR ALL
Subtask 36-12-00-860-055-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:14:25 UTC
Pressurization of the Bleed System with the APU
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
| TASK 49-00-00-860-005-A | APU Start by External Power |
| TASK 49-00-00-860-005-A-01 | APU Start by Batteries |
| TASK 49-00-00-860-006-A | APU Shutdown by External Power |
| TASK 49-00-00-860-006-A-01 | APU Shutdown by Batteries |
| TASK 49-00-00-860-008-A | APU Start by External Power |
| TASK 49-00-00-860-008-A-01 | APU Start by Batteries |
| TASK 49-00-00-860-009-A | APU Shutdown by External Power (131-9(A)) |
| TASK 49-00-00-860-009-A-01 | APU Shutdown by Batteries (131-9(A)) |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
Subtask 36-12-00-941-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(2) Install a WARNING NOTICE(S) on the access door 811 to tell persons not to close the access door 811.
Subtask 36-12-00-860-054-A ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE FWD AVIONICS ACCESS DOOR 811 IS OPEN WITH A WARNING PLACARD ATTACHED TO IT.
THE WARNING NOTICE MUST TELL PERSONS NOT TO CLOSE THE DOOR. THIS PREVENTS ACCIDENTAL PRESSURIZATION OF THE AIRCRAFT.
(1) When you operate the air condioning make sure that the access door 811 is open (Ref. AMM TASK 52-41-00-010-002). (2) Install a WARNING NOTICE(S) on the access door 811 to tell persons not to close the access door 811.
B. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
(3) On the AIR COND overhead panel 30VU:
Subtask 36-12-00-865-053-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
(3) On the AIR COND overhead panel 30VU:
- Release the PACK 1 and PACK 2 P/BSWs to off (the OFF legends come on)
- Make sure that the X-bleed selector switch is in the AUTO position.
C. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | APU/APU/CTL | 2KD | L42 |
| 121VU | APU/ECB/SPLY | 1KD | L41 |
| 122VU | AIR BLEED/X FEED VALVE/NORM | 1HV | Z20 |
Subtask 36-12-00-869-055-B ** ON A/C NOT FOR ALL
A. Pressurization of the Bleed System with the APU
(1) Start and operate the APU (Ref. AMM TASK 49-00-00-860-005).
(3) On the ECAM control panel, push the BLEED key (the BLEED page comes into view).
(4) On the AIR BLEED page of the ECAM lower DU, make sure that all indications shown are normal (i.e. green indication).
(5) When the pressurization of the bleed system is no longer necessary:
Subtask 36-12-00-869-055-C ** ON A/C NOT FOR ALL (1) Start and operate the APU (Ref. AMM TASK 49-00-00-860-005).
NOTE: After the APU starts, Airbus recommends you to wait for a minimum of 3 minutes for the warm up period, before you select the APU BLEED.
(2) On AIR COND overhead panel 30VU, push the APU BLEED pushbutton-switch to ON (the ON legend comes on). (3) On the ECAM control panel, push the BLEED key (the BLEED page comes into view).
(4) On the AIR BLEED page of the ECAM lower DU, make sure that all indications shown are normal (i.e. green indication).
(5) When the pressurization of the bleed system is no longer necessary:
- On the AIR COND overhead panel 30VU, release the APU BLEED pushbutton-switch to off (the ON legend goes off)
- Shutdown the APU (Ref. AMM TASK 49-00-00-860-006).
A. Pressurization of the Bleed System with the APU
(1) Start and operate the APU (Ref. AMM TASK 49-00-00-860-008).
(3) On the ECAM control panel, push the APU key (the APU page comes into view).
(4) On the AIR BLEED page of the ECAM lower DU, make sure that all indications shown are normal (i.e. green indication).
(5) When the pressurization of the bleed system is no longer necessary:
5. Close-up(1) Start and operate the APU (Ref. AMM TASK 49-00-00-860-008).
NOTE: After the APU starts, Airbus recommends you to wait for a minimum of 3 minutes of warm up period before you select the APU BLEED.
(2) On the AIR COND overhead panel 30VU, push the APU BLEED P/BSW to ON (the ON legend comes on). (3) On the ECAM control panel, push the APU key (the APU page comes into view).
(4) On the AIR BLEED page of the ECAM lower DU, make sure that all indications shown are normal (i.e. green indication).
(5) When the pressurization of the bleed system is no longer necessary:
- On the AIR COND overhead panel 30VU, release the APU BLEED P/BSW to off (the ON legend goes off)
- Shutdown the APU (Ref. AMM TASK 49-00-00-860-009).
Subtask 36-12-00-860-055-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) On the AIR COND overhead panel 30VU:
(Ref. AMM TASK 31-60-00-860-002).
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(4) If the access door 811 is open:
(1) On the AIR COND overhead panel 30VU:
- Push the PACK 1 and PACK 2 P/BSWs to ON (the OFF legends goes OFF)
- Make sure that the X-bleed selector switch is in the AUTO position.
(Ref. AMM TASK 31-60-00-860-002).
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(4) If the access door 811 is open:
- Remove the WARNING NOTICE(S).
- Close the access door 811 (Ref. AMM TASK 52-41-00-410-002).