W DOC AIRBUS | AMM A320F

Leak Test of the APU Bleed-Air Supply-System


TASK 36-12-00-790-001-A
Leak Test of the APU Bleed-Air Supply-System


WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT)
No specific
AR
ACCESS PLATFORM 3M (10 FT)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
147AB, 147EB, 147FB, 151BW, 161AW, 161BW, 161CW, 161DW, 191BB, 191EB, 191JB, 197BB, 312AR, 314AR
151CW, 151DW, 151EW, 151HW, 151JW
151RW
151SW, 151TW, 151UW, 151VW
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 25-55-11-000-001-A
Removal of the Aft Cargo-Compartment Partition at FR47
TASK 25-55-11-400-001-A
Installation of the Aft Cargo-Compartment Partition at FR47
TASK 25-55-12-000-001-A
Removal of the Aft Cargo-Compartment Partition at FR65
TASK 25-55-12-400-001-A
Installation of the Aft Cargo-Compartment Partition at FR65
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
TASK 36-22-00-790-001-A
Leak Check on all the Bleed Air Ducts and the Packs Components
TASK 49-00-00-860-005-A
APU Start by External Power
TASK 49-00-00-860-005-A-01
APU Start by Batteries
TASK 49-00-00-860-006-A
APU Shutdown by External Power
TASK 49-00-00-860-006-A-01
APU Shutdown by Batteries
TASK 49-00-00-860-008-A
APU Start by External Power
TASK 49-00-00-860-008-A-01
APU Start by Batteries
TASK 49-00-00-860-009-A
APU Shutdown by External Power (131-9(A))
TASK 49-00-00-860-009-A-01
APU Shutdown by Batteries (131-9(A))
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 52-30-00-860-002-A
Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
F APU Bleed Air Ducts - Access ** ON A/C NOT FOR ALL
F APU Bleed Air Ducts - Access ** ON A/C NOT FOR ALL
F APU Bleed Air Ducts - Access ** ON A/C NOT FOR ALL
F APU Bleed Air Ducts - Access ** ON A/C NOT FOR ALL
F APU Bleed Air Ducts - Access ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 36-12-00-010-052-A ** ON A/C NOT FOR ALL
A. Get Access
F APU Bleed Air Ducts - Access ** ON A/C NOT FOR ALL
F APU Bleed Air Ducts - Access ** ON A/C NOT FOR ALL
NOTE: Remove only the related access panels in the area where you will do the leak test.
   (1) Get access to the APU bleed-air ducts between FR35 and FR36.
     (a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panels 191BB and 191EB.
     (b) Remove the access panels 191BB and 191EB.
   (2) Get access to the APU bleed-air ducts between FR36 and FR42.
     (a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panel 191JB.
     (b) Remove the access panel 191JB.
   (3) Get access to the APU bleed-air ducts between FR42 and FR50.
     (a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panels 147AB, 147EB, 147FB and 197BB.
     (b) Remove the access panels 147AB, 147EB, 147FB and 197BB.
   (4) Get access to the APU bleed-air ducts between FR46 and FR70 from the AFT cargo compartment.
     (a) Open the AFT cargo compartment door (Ref. AMM TASK 52-30-00-860-001).
     (b) Remove the applicable access panels for the APU bleed-air ducts:
  • between the FR46 and FR47
    remove the partition panel 151BW (Ref. AMM TASK 25-55-11-000-001)
  • between the FR47 and FR49
    remove the access panel 151CW
  • between the FR49 and FR52
    remove the access panel 151DW
  • between the FR52 and FR55
    remove the access panel 151EW
  • between the FR55 and FR58
    remove the access panel 151HW
  • between the FR58 and FR59
    remove the access panel 151JW
  • between the FR59 and FR62
    remove the access panel 161AW
  • between the FR62 and FR63
    remove the access panel 161BW
  • between the FR63 and FR65
    remove the access panel 161CW
  • between the FR65 and FR70
    remove partition panel 161DW (Ref. AMM TASK 25-55-12-000-001).
   (5) Get access to the APU bleed-air duct aft of FR70.
     (a) Put the ACCESS PLATFORM 3M (10 FT) below the rear fuselage.
     (b) Open the applicable access door for the APU bleed-air ducts:
  • between the FR70 and FR77
    open the access door 312AR,
  • aft of FR77
    open the access door 314AR.
Subtask 36-12-00-010-052-B ** ON A/C NOT FOR ALL
A. Get Access
F APU Bleed Air Ducts - Access ** ON A/C NOT FOR ALL
F APU Bleed Air Ducts - Access ** ON A/C NOT FOR ALL
NOTE: Remove only the related access panels in the area where you will do the leak test.
   (1) Get access to the APU bleed-air ducts between FR35 and FR36.
     (a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panels 191BB and 191EB.
     (b) Remove the access panels 191BB and 191EB.
   (2) Get access to the APU bleed-air ducts between FR36 and FR42.
     (a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panel 191JB.
     (b) Remove the access panel 191JB.
   (3) Get access to the APU bleed-air ducts between FR42 and FR50.
     (a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panels 147AB, 147EB, 147FB and 197BB.
     (b) Remove the access panels 147AB, 147EB, 147FB and 197BB.
   (4) Get access to the APU bleed-air ducts between FR46 and FR70 from the AFT cargo compartment.
     (a) Open the AFT cargo compartment door (Ref. AMM TASK 52-30-00-860-001).
     (b) Remove the applicable access panels for the APU bleed-air ducts:
  • between the FR46 and FR47
    remove the partition panel 151BW (Ref. AMM TASK 25-55-11-000-001)
  • between the FR47 and FR47.4
    remove the access panel 151RW
  • between the FR47.4 and FR49
    remove the access panel 151CW
  • between the FR49 and FR52
    remove the access panel 151DW
  • between the FR52 and FR55
    remove the access panel 151EW
  • between the FR55 and FR58
    remove the access panel 151HW
  • between the FR58 and FR59
    remove the access panel 151JW
  • between the FR59 and FR62
    remove the access panel 161AW
  • between the FR62 and FR63
    remove the access panel 161BW
  • between the FR63 and FR65
    remove the access panel 161CW
  • between the FR65 and FR70
    remove the partition panel 161DW (Ref. AMM TASK 25-55-12-000-001).
   (5) Get access to the APU bleed-air duct aft of FR70.
     (a) Put the ACCESS PLATFORM 3M (10 FT) below the rear fuselage.
     (b) Open the applicable access door for the APU bleed-air ducts:
  • between the FR70 and FR77
    open the access door 312AR,
  • aft of FR77
    open the access door 314AR.
Subtask 36-12-00-010-052-C ** ON A/C NOT FOR ALL
A. Get Access
F APU Bleed Air Ducts - Access ** ON A/C NOT FOR ALL
NOTE: Remove only the related access panels in the area where you will do the leak test.
   (1) Get access to the APU bleed-air ducts between FR35 and FR36.
     (a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panels 191BB and 191EB.
     (b) Remove the access panels 191BB and 191EB.
   (2) Get access to the APU bleed-air ducts between FR36 and FR42.
     (a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panel 191JB.
     (b) Remove the access panel 191JB.
   (3) Get access to the APU bleed-air ducts between FR42 and FR50.
     (a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panels 147AB, 147EB, 147FB and 197BB.
     (b) Remove the access panels 147AB, 147EB, 147FB and 197BB.
   (4) Get access to the APU bleed-air ducts between FR46 and FR70 from the AFT cargo compartment.
     (a) Open the AFT cargo compartment door (Ref. AMM TASK 52-30-00-860-001).
     (b) Remove the applicable access panels for the APU bleed-air ducts:
  • between the FR46 and FR53
    remove the partition panel 151BW (Ref. AMM TASK 25-55-11-000-001) and remove the access panel 151SW
  • between the FR53 and FR56
    remove the access panel 151TW
  • between the FR56 and FR58
    remove the access panel 151UW
  • between the FR58 and FR59
    remove the access panel 151VW
  • between the FR59 and FR62
    remove the access panel 161AW
  • between the FR62 and FR63
    remove the access panel 161BW
  • between the FR63 and FR65
    remove the access panel 161CW
  • between the FR65 and FR70
    remove the partition panel 161DW (Ref. AMM TASK 25-55-12-000-001).
   (5) Get access to the APU bleed-air duct aft of FR70.
     (a) Put the ACCESS PLATFORM 3M (10 FT) below the rear fuselage.
     (b) Open the applicable access door for the APU bleed-air ducts:
  • between the FR70 and FR77
    open the access door 312AR,
  • aft of FR77
    open the access door 314AR.
Subtask 36-12-00-865-055-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR BLEED/ENG 1/CTL3HA1D12
49VUAIR BLEED/ENG 1/MONG2HA1D11
** ON A/C ALL
49VUAIR BLEED/X FEED/VALVE/BAT2HVD13
** ON A/C NOT FOR ALL
49VUAIR BLEED/ENG 2/MONG3HA2D12
49VUAIR BLEED/ENG 1/CTL2HA1D11
** ON A/C ALL
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
** ON A/C NOT FOR ALL
122VUAIR BLEED/ENG 2/CTL3HA2Z23
122VUAIR BLEED/ENG 2/MONG2HA2Z22
** ON A/C ALL
122VUAIR BLEED/X FEED VALVE/NORM1HVZ20
** ON A/C NOT FOR ALL
122VUAIR BLEED/ENG 1/MONG3HA1Z23
122VUAIR BLEED/ENG 2/CTL2HA2Z22
Subtask 36-12-00-860-058-A
C. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
   (2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
   (3) On the AIR COND panel 30VU, make sure that:
  • The OFF legends on the PACK 1 and PACK 2 pushbutton switches are on,
  • the OFF legends of the ENG BLEED pushbutton switches are on,
  • the X-BLEED selector switch is in the SHUT position.
   (4) On the ANTI ICE panel 25VU, make sure that:
  • The ANTI ICE pushbutton switches are off (the ON legends are off).
4. Procedure
Subtask 36-12-00-720-050-B ** ON A/C NOT FOR ALL
A. Leak Test of the APU Bleed-Air Supply-System
   (1) Start the APU (Ref. AMM TASK 49-00-00-860-005).
NOTE: After the APU starts, Airbus recommends you to wait for a minimum of 3 minutes for the warm up period, before you select the APU BLEED.
   (2) On AIR COND panel 30VU:
  • Push the APU BLEED pushbutton-switch (the ON legend comes on).
   (3) On the BLEED page of the lower ECAM DU, make sure that:
  • The APU bleed-air supply is correct.
   (4) At the APU bleed-air ducts (Ref. AMM TASK 36-22-00-790-001), make sure that there are no leaks from:
  • Clamps
  • Connections
  • Ducts.
Subtask 36-12-00-720-050-C ** ON A/C NOT FOR ALL
A. Leak Test of the APU Bleed-Air Supply-System
   (1) Start the APU (Ref. AMM TASK 49-00-00-860-008).
NOTE: After the APU starts, Airbus recommends you to wait for a minimum of 3 minutes of warm up period before you select the APU BLEED.
   (2) On AIR COND panel 30VU:
  • Push the APU BLEED P/BSW (the ON legend comes on).
   (3) On the BLEED page of the lower ECAM DU, make sure that:
  • The APU bleed air-supply is correct.
   (4) At the APU bleed-air ducts, make sure that there are no leaks from (Ref. AMM TASK 36-22-00-790-001):
  • The clamps
  • The connections
  • The ducts.
5. Close-up
Subtask 36-12-00-860-059-B ** ON A/C NOT FOR ALL
A. Put the aircraft back to the serviceable condition.
   (1) On the AIR COND panel 30VU, push the APU BLEED pushbutton switch (the OFF legend comes on).
   (2) Shut down the APU (Ref. AMM TASK 49-00-00-860-006).
   (3) On the AIR COND panel 30VU, set the X-BLEED selector switch in the AUTO position.
   (4) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
   (5) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
Subtask 36-12-00-860-059-C ** ON A/C NOT FOR ALL
A. Put the aircraft back to the serviceable condition.
   (1) On the AIR COND panel 30VU, push the APU BLEED pushbutton switch (the OFF legend comes on).
   (2) Shut down the APU (Ref. AMM TASK 49-00-00-860-009).
   (3) On the AIR COND panel 30VU, set the X-BLEED selector switch in the AUTO position.
   (4) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
   (5) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
Subtask 36-12-00-410-052-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) For the APU bleed-air ducts between FR35 and FR36:
     (a) Install the access panels 191BB and 191EB.
     (b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panels 191BB and 191EB.
   (3) For the APU bleed-air ducts between FR36 and FR42:
     (a) Install the access panel 191JB.
     (b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panel 191JB.
   (4) For the APU bleed-air ducts between FR42 and FR50:
     (a) Install the access panels 147AB, 147EB, 147FB and 197BB.
     (b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panels 147AB, 147EB, 147FB and 197BB.
   (5) For the APU bleed-air ducts between the FR46 and FR47:
     (a) Install the partition panel 151BW (Ref. AMM TASK 25-55-11-400-001).
   (6) For the APU bleed-air ducts between the FR47 and FR49:
  • Install the access panel 151CW.
   (7) For the APU bleed-air ducts between the FR49 and FR52:
  • Install the access panel 151DW.
   (8) For the APU bleed-air ducts between the FR52 and FR55:
  • Install the access panel 151EW.
   (9) For the APU bleed-air ducts between the FR55 and FR58:
  • Install the access panel 151HW.
   (10) For the APU bleed-air ducts between FR58 and FR59:
  • Install the access panel 151JW.
   (11) For the APU bleed-air ducts between the FR59 and FR62:
  • Install the access panel 161AW.
   (12) For the APU bleed-air ducts between the FR62 and FR63:
  • Install the access panel 161BW.
   (13) For the APU bleed-air ducts between the FR63 and FR65:
  • Install the access panel 161CW.
   (14) For the APU bleed-air ducts between the FR65 and FR70:
   (15) Close the AFT cargo compartment door (Ref. AMM TASK 52-30-00-860-002).
   (16) For the APU bleed-air ducts between the FR70 and FR77:
  • Close the access door 312AR.
   (17) For the APU bleed-air ducts aft of FR77:
  • Close the access door 314AR.
   (18) Remove the ACCESS PLATFORM 3M (10 FT) from below the rear fuselage.
   (19) Remove the WARNING NOTICE(S).
Subtask 36-12-00-410-052-B ** ON A/C NOT FOR ALL
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) For the APU bleed-air ducts between FR35 and FR36:
     (a) Install the access panels 191BB and 191EB.
     (b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panels 191BB and 191EB.
   (3) For the APU bleed-air ducts between FR36 and FR42:
     (a) Install the access panel 191JB.
     (b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panel 191JB.
   (4) For the APU bleed-air ducts between FR42 and FR50:
     (a) Install the access panels 147AB, 147EB, 147FB and 197BB.
     (b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panels 147AB, 147EB, 147FB and 197BB.
   (5) For the APU bleed-air ducts between the FR46 and FR47:
   (6) For the APU bleed-air ducts between the FR47 and 47.4:
  • Install the access panel 151RW.
   (7) For the APU bleed-air ducts between the FR47.4 and FR49:
  • Install the access panel 151CW.
   (8) For the APU bleed-air ducts between the FR49 and FR52:
  • Install the access panel 151DW.
   (9) For the APU bleed-air ducts between the FR52 and FR55:
  • Install the access panel 151EW.
   (10) For the APU bleed-air ducts between the FR55 and FR58:
  • Install the access panel 151HW.
   (11) For the APU bleed-air ducts between FR58 and FR59:
  • Install the access panel 151JW.
   (12) For the APU bleed-air ducts between the FR59 and FR62:
  • Install the access panel 161AW.
   (13) For the APU bleed-air ducts between the FR62 and FR63:
  • Install the access panel 161BW.
   (14) For the APU bleed-air ducts between the FR63 and FR65:
  • Install the access panel 161CW.
   (15) For the APU bleed-air ducts between the FR65 and FR70:
   (16) Close the AFT cargo compartment door (Ref. AMM TASK 52-30-00-860-002).
   (17) For the APU bleed-air ducts between the FR70 and FR77:
  • Close the access door 312AR.
   (18) For the APU bleed-air ducts aft of FR77:
  • Close the access door 314AR.
   (19) Remove the ACCESS PLATFORM 3M (10 FT) from below the rear fuselage.
   (20) Remove the WARNING NOTICE(S).
Subtask 36-12-00-410-052-C ** ON A/C NOT FOR ALL
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) For the APU bleed-air ducts between FR35 and FR36:
     (a) Install the access panels 191BB and 191EB.
     (b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panels 191BB and 191EB.
   (3) For the APU bleed-air ducts between FR36 and FR42:
     (a) Install the access panel 191JB.
     (b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panel 191JB.
   (4) For the APU bleed-air ducts between FR42 and FR50:
     (a) Install the access panels 147AB, 147EB, 147FB and 197BB.
     (b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panels 147AB, 147EB, 147FB and 197BB.
   (5) For the APU bleed-air ducts between the FR46 and FR53:
   (6) For the APU bleed-air ducts between the FR53 and FR56:
  • Install the access panel 151TW.
   (7) For the APU bleed-air ducts between the FR56 and FR58:
  • Install the access panel 151UW.
   (8) For the APU bleed-air ducts between the FR58 and FR59:
  • Install the access panel 151VW.
   (9) For the APU bleed-air ducts between the FR59 and FR62:
  • Install the access panel 161AW.
   (10) For the APU bleed-air ducts between FR62 and FR63:
  • Install the access panel 161BW.
   (11) For the APU bleed-air ducts between the FR63 and FR65:
  • Install the access panel 161CW.
   (12) For the APU bleed-air ducts between the FR65 and FR70:
   (13) Close the AFT cargo compartment door (Ref. AMM TASK 52-30-00-860-002).
   (14) For the APU bleed-air ducts between the FR70 and FR77:
  • Close the access door 312AR.
   (15) For the APU bleed-air ducts aft of FR77:
  • Close the access door 314AR.
   (16) Remove the ACCESS PLATFORM 3M (10 FT) from below the rear fuselage.
   (17) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 01:15:22 UTC