Leak Test of the APU Bleed-Air Supply-System
TASK 36-12-00-790-001-A
Leak Test of the APU Bleed-Air Supply-System
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 36-12-00-010-052-A ** ON A/C NOT FOR ALL
Subtask 36-12-00-720-050-B ** ON A/C NOT FOR ALL
Subtask 36-12-00-860-059-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:15:22 UTC
Leak Test of the APU Bleed-Air Supply-System
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | ACCESS PLATFORM 3M (10 FT) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 147AB, 147EB, 147FB, 151BW, 161AW, 161BW, 161CW, 161DW, 191BB, 191EB, 191JB, 197BB, 312AR, 314AR | |
| 151CW, 151DW, 151EW, 151HW, 151JW | |
| 151RW | |
| 151SW, 151TW, 151UW, 151VW |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 25-55-11-000-001-A | Removal of the Aft Cargo-Compartment Partition at FR47 |
| TASK 25-55-11-400-001-A | Installation of the Aft Cargo-Compartment Partition at FR47 |
| TASK 25-55-12-000-001-A | Removal of the Aft Cargo-Compartment Partition at FR65 |
| TASK 25-55-12-400-001-A | Installation of the Aft Cargo-Compartment Partition at FR65 |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
| TASK 36-22-00-790-001-A | Leak Check on all the Bleed Air Ducts and the Packs Components |
| TASK 49-00-00-860-005-A | APU Start by External Power |
| TASK 49-00-00-860-005-A-01 | APU Start by Batteries |
| TASK 49-00-00-860-006-A | APU Shutdown by External Power |
| TASK 49-00-00-860-006-A-01 | APU Shutdown by Batteries |
| TASK 49-00-00-860-008-A | APU Start by External Power |
| TASK 49-00-00-860-008-A-01 | APU Start by Batteries |
| TASK 49-00-00-860-009-A | APU Shutdown by External Power (131-9(A)) |
| TASK 49-00-00-860-009-A-01 | APU Shutdown by Batteries (131-9(A)) |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 36-12-00-010-052-A ** ON A/C NOT FOR ALL
A. Get Access
APU Bleed Air Ducts - Access ** ON A/C NOT FOR ALL
APU Bleed Air Ducts - Access ** ON A/C NOT FOR ALL
(a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panels 191BB and 191EB.
(b) Remove the access panels 191BB and 191EB.
(2) Get access to the APU bleed-air ducts between FR36 and FR42.
(a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panel 191JB.
(b) Remove the access panel 191JB.
(3) Get access to the APU bleed-air ducts between FR42 and FR50.
(a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panels 147AB, 147EB, 147FB and 197BB.
(b) Remove the access panels 147AB, 147EB, 147FB and 197BB.
(4) Get access to the APU bleed-air ducts between FR46 and FR70 from the AFT cargo compartment.
(a) Open the AFT cargo compartment door (Ref. AMM TASK 52-30-00-860-001).
(b) Remove the applicable access panels for the APU bleed-air ducts:
(a) Put the ACCESS PLATFORM 3M (10 FT) below the rear fuselage.
(b) Open the applicable access door for the APU bleed-air ducts:
Subtask 36-12-00-010-052-B ** ON A/C NOT FOR ALL
APU Bleed Air Ducts - Access ** ON A/C NOT FOR ALL
APU Bleed Air Ducts - Access ** ON A/C NOT FOR ALL NOTE: Remove only the related access panels in the area where you will do the leak test.
(1) Get access to the APU bleed-air ducts between FR35 and FR36. (a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panels 191BB and 191EB.
(b) Remove the access panels 191BB and 191EB.
(2) Get access to the APU bleed-air ducts between FR36 and FR42.
(a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panel 191JB.
(b) Remove the access panel 191JB.
(3) Get access to the APU bleed-air ducts between FR42 and FR50.
(a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panels 147AB, 147EB, 147FB and 197BB.
(b) Remove the access panels 147AB, 147EB, 147FB and 197BB.
(4) Get access to the APU bleed-air ducts between FR46 and FR70 from the AFT cargo compartment.
(a) Open the AFT cargo compartment door (Ref. AMM TASK 52-30-00-860-001).
(b) Remove the applicable access panels for the APU bleed-air ducts:
- between the FR46 and FR47
remove the partition panel 151BW (Ref. AMM TASK 25-55-11-000-001) - between the FR47 and FR49
remove the access panel 151CW - between the FR49 and FR52
remove the access panel 151DW - between the FR52 and FR55
remove the access panel 151EW - between the FR55 and FR58
remove the access panel 151HW - between the FR58 and FR59
remove the access panel 151JW - between the FR59 and FR62
remove the access panel 161AW - between the FR62 and FR63
remove the access panel 161BW - between the FR63 and FR65
remove the access panel 161CW - between the FR65 and FR70
remove partition panel 161DW (Ref. AMM TASK 25-55-12-000-001).
(a) Put the ACCESS PLATFORM 3M (10 FT) below the rear fuselage.
(b) Open the applicable access door for the APU bleed-air ducts:
A. Get Access
APU Bleed Air Ducts - Access ** ON A/C NOT FOR ALL
APU Bleed Air Ducts - Access ** ON A/C NOT FOR ALL
(a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panels 191BB and 191EB.
(b) Remove the access panels 191BB and 191EB.
(2) Get access to the APU bleed-air ducts between FR36 and FR42.
(a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panel 191JB.
(b) Remove the access panel 191JB.
(3) Get access to the APU bleed-air ducts between FR42 and FR50.
(a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panels 147AB, 147EB, 147FB and 197BB.
(b) Remove the access panels 147AB, 147EB, 147FB and 197BB.
(4) Get access to the APU bleed-air ducts between FR46 and FR70 from the AFT cargo compartment.
(a) Open the AFT cargo compartment door (Ref. AMM TASK 52-30-00-860-001).
(b) Remove the applicable access panels for the APU bleed-air ducts:
(a) Put the ACCESS PLATFORM 3M (10 FT) below the rear fuselage.
(b) Open the applicable access door for the APU bleed-air ducts:
Subtask 36-12-00-010-052-C ** ON A/C NOT FOR ALL
APU Bleed Air Ducts - Access ** ON A/C NOT FOR ALL
APU Bleed Air Ducts - Access ** ON A/C NOT FOR ALL NOTE: Remove only the related access panels in the area where you will do the leak test.
(1) Get access to the APU bleed-air ducts between FR35 and FR36. (a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panels 191BB and 191EB.
(b) Remove the access panels 191BB and 191EB.
(2) Get access to the APU bleed-air ducts between FR36 and FR42.
(a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panel 191JB.
(b) Remove the access panel 191JB.
(3) Get access to the APU bleed-air ducts between FR42 and FR50.
(a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panels 147AB, 147EB, 147FB and 197BB.
(b) Remove the access panels 147AB, 147EB, 147FB and 197BB.
(4) Get access to the APU bleed-air ducts between FR46 and FR70 from the AFT cargo compartment.
(a) Open the AFT cargo compartment door (Ref. AMM TASK 52-30-00-860-001).
(b) Remove the applicable access panels for the APU bleed-air ducts:
- between the FR46 and FR47
remove the partition panel 151BW (Ref. AMM TASK 25-55-11-000-001) - between the FR47 and FR47.4
remove the access panel 151RW - between the FR47.4 and FR49
remove the access panel 151CW - between the FR49 and FR52
remove the access panel 151DW - between the FR52 and FR55
remove the access panel 151EW - between the FR55 and FR58
remove the access panel 151HW - between the FR58 and FR59
remove the access panel 151JW - between the FR59 and FR62
remove the access panel 161AW - between the FR62 and FR63
remove the access panel 161BW - between the FR63 and FR65
remove the access panel 161CW - between the FR65 and FR70
remove the partition panel 161DW (Ref. AMM TASK 25-55-12-000-001).
(a) Put the ACCESS PLATFORM 3M (10 FT) below the rear fuselage.
(b) Open the applicable access door for the APU bleed-air ducts:
A. Get Access
(a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panels 191BB and 191EB.
(b) Remove the access panels 191BB and 191EB.
(2) Get access to the APU bleed-air ducts between FR36 and FR42.
(a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panel 191JB.
(b) Remove the access panel 191JB.
(3) Get access to the APU bleed-air ducts between FR42 and FR50.
(a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panels 147AB, 147EB, 147FB and 197BB.
(b) Remove the access panels 147AB, 147EB, 147FB and 197BB.
(4) Get access to the APU bleed-air ducts between FR46 and FR70 from the AFT cargo compartment.
(a) Open the AFT cargo compartment door (Ref. AMM TASK 52-30-00-860-001).
(b) Remove the applicable access panels for the APU bleed-air ducts:
(a) Put the ACCESS PLATFORM 3M (10 FT) below the rear fuselage.
(b) Open the applicable access door for the APU bleed-air ducts:
Subtask 36-12-00-865-055-A NOTE: Remove only the related access panels in the area where you will do the leak test.
(1) Get access to the APU bleed-air ducts between FR35 and FR36. (a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panels 191BB and 191EB.
(b) Remove the access panels 191BB and 191EB.
(2) Get access to the APU bleed-air ducts between FR36 and FR42.
(a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panel 191JB.
(b) Remove the access panel 191JB.
(3) Get access to the APU bleed-air ducts between FR42 and FR50.
(a) Put the ACCESS PLATFORM 2M (6 FT) in position below the access panels 147AB, 147EB, 147FB and 197BB.
(b) Remove the access panels 147AB, 147EB, 147FB and 197BB.
(4) Get access to the APU bleed-air ducts between FR46 and FR70 from the AFT cargo compartment.
(a) Open the AFT cargo compartment door (Ref. AMM TASK 52-30-00-860-001).
(b) Remove the applicable access panels for the APU bleed-air ducts:
- between the FR46 and FR53
remove the partition panel 151BW (Ref. AMM TASK 25-55-11-000-001) and remove the access panel 151SW - between the FR53 and FR56
remove the access panel 151TW - between the FR56 and FR58
remove the access panel 151UW - between the FR58 and FR59
remove the access panel 151VW - between the FR59 and FR62
remove the access panel 161AW - between the FR62 and FR63
remove the access panel 161BW - between the FR63 and FR65
remove the access panel 161CW - between the FR65 and FR70
remove the partition panel 161DW (Ref. AMM TASK 25-55-12-000-001).
(a) Put the ACCESS PLATFORM 3M (10 FT) below the rear fuselage.
(b) Open the applicable access door for the APU bleed-air ducts:
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 36-12-00-860-058-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR BLEED/ENG 1/CTL | 3HA1 | D12 |
| 49VU | AIR BLEED/ENG 1/MONG | 2HA1 | D11 |
| ** ON A/C ALL | |||
| 49VU | AIR BLEED/X FEED/VALVE/BAT | 2HV | D13 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR BLEED/ENG 2/MONG | 3HA2 | D12 |
| 49VU | AIR BLEED/ENG 1/CTL | 2HA1 | D11 |
| ** ON A/C ALL | |||
| 121VU | APU/APU/CTL | 2KD | L42 |
| 121VU | APU/ECB/SPLY | 1KD | L41 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR BLEED/ENG 2/CTL | 3HA2 | Z23 |
| 122VU | AIR BLEED/ENG 2/MONG | 2HA2 | Z22 |
| ** ON A/C ALL | |||
| 122VU | AIR BLEED/X FEED VALVE/NORM | 1HV | Z20 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR BLEED/ENG 1/MONG | 3HA1 | Z23 |
| 122VU | AIR BLEED/ENG 2/CTL | 2HA2 | Z22 |
C. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
(3) On the AIR COND panel 30VU, make sure that:
4. Procedure(1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
(3) On the AIR COND panel 30VU, make sure that:
- The OFF legends on the PACK 1 and PACK 2 pushbutton switches are on,
- the OFF legends of the ENG BLEED pushbutton switches are on,
- the X-BLEED selector switch is in the SHUT position.
- The ANTI ICE pushbutton switches are off (the ON legends are off).
Subtask 36-12-00-720-050-B ** ON A/C NOT FOR ALL
A. Leak Test of the APU Bleed-Air Supply-System
(1) Start the APU (Ref. AMM TASK 49-00-00-860-005).
Subtask 36-12-00-720-050-C ** ON A/C NOT FOR ALL (1) Start the APU (Ref. AMM TASK 49-00-00-860-005).
NOTE: After the APU starts, Airbus recommends you to wait for a minimum of 3 minutes for the warm up period, before you select the APU BLEED.
(2) On AIR COND panel 30VU: - Push the APU BLEED pushbutton-switch (the ON legend comes on).
- The APU bleed-air supply is correct.
- Clamps
- Connections
- Ducts.
A. Leak Test of the APU Bleed-Air Supply-System
(1) Start the APU (Ref. AMM TASK 49-00-00-860-008).
5. Close-up(1) Start the APU (Ref. AMM TASK 49-00-00-860-008).
NOTE: After the APU starts, Airbus recommends you to wait for a minimum of 3 minutes of warm up period before you select the APU BLEED.
(2) On AIR COND panel 30VU: - Push the APU BLEED P/BSW (the ON legend comes on).
- The APU bleed air-supply is correct.
- The clamps
- The connections
- The ducts.
Subtask 36-12-00-860-059-B ** ON A/C NOT FOR ALL
A. Put the aircraft back to the serviceable condition.
(1) On the AIR COND panel 30VU, push the APU BLEED pushbutton switch (the OFF legend comes on).
(2) Shut down the APU (Ref. AMM TASK 49-00-00-860-006).
(3) On the AIR COND panel 30VU, set the X-BLEED selector switch in the AUTO position.
(4) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(5) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
Subtask 36-12-00-860-059-C ** ON A/C NOT FOR ALL (1) On the AIR COND panel 30VU, push the APU BLEED pushbutton switch (the OFF legend comes on).
(2) Shut down the APU (Ref. AMM TASK 49-00-00-860-006).
(3) On the AIR COND panel 30VU, set the X-BLEED selector switch in the AUTO position.
(4) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(5) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
A. Put the aircraft back to the serviceable condition.
(1) On the AIR COND panel 30VU, push the APU BLEED pushbutton switch (the OFF legend comes on).
(2) Shut down the APU (Ref. AMM TASK 49-00-00-860-009).
(3) On the AIR COND panel 30VU, set the X-BLEED selector switch in the AUTO position.
(4) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(5) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
Subtask 36-12-00-410-052-A ** ON A/C NOT FOR ALL (1) On the AIR COND panel 30VU, push the APU BLEED pushbutton switch (the OFF legend comes on).
(2) Shut down the APU (Ref. AMM TASK 49-00-00-860-009).
(3) On the AIR COND panel 30VU, set the X-BLEED selector switch in the AUTO position.
(4) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(5) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) For the APU bleed-air ducts between FR35 and FR36:
(a) Install the access panels 191BB and 191EB.
(b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panels 191BB and 191EB.
(3) For the APU bleed-air ducts between FR36 and FR42:
(a) Install the access panel 191JB.
(b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panel 191JB.
(4) For the APU bleed-air ducts between FR42 and FR50:
(a) Install the access panels 147AB, 147EB, 147FB and 197BB.
(b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panels 147AB, 147EB, 147FB and 197BB.
(5) For the APU bleed-air ducts between the FR46 and FR47:
(a) Install the partition panel 151BW (Ref. AMM TASK 25-55-11-400-001).
(6) For the APU bleed-air ducts between the FR47 and FR49:
(16) For the APU bleed-air ducts between the FR70 and FR77:
(19) Remove the WARNING NOTICE(S).
Subtask 36-12-00-410-052-B ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) For the APU bleed-air ducts between FR35 and FR36:
(a) Install the access panels 191BB and 191EB.
(b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panels 191BB and 191EB.
(3) For the APU bleed-air ducts between FR36 and FR42:
(a) Install the access panel 191JB.
(b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panel 191JB.
(4) For the APU bleed-air ducts between FR42 and FR50:
(a) Install the access panels 147AB, 147EB, 147FB and 197BB.
(b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panels 147AB, 147EB, 147FB and 197BB.
(5) For the APU bleed-air ducts between the FR46 and FR47:
(a) Install the partition panel 151BW (Ref. AMM TASK 25-55-11-400-001).
(6) For the APU bleed-air ducts between the FR47 and FR49:
- Install the access panel 151CW.
- Install the access panel 151DW.
- Install the access panel 151EW.
- Install the access panel 151HW.
- Install the access panel 151JW.
- Install the access panel 161AW.
- Install the access panel 161BW.
- Install the access panel 161CW.
- Install the partition panel 161DW (Ref. AMM TASK 25-55-12-400-001).
(16) For the APU bleed-air ducts between the FR70 and FR77:
- Close the access door 312AR.
- Close the access door 314AR.
(19) Remove the WARNING NOTICE(S).
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) For the APU bleed-air ducts between FR35 and FR36:
(a) Install the access panels 191BB and 191EB.
(b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panels 191BB and 191EB.
(3) For the APU bleed-air ducts between FR36 and FR42:
(a) Install the access panel 191JB.
(b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panel 191JB.
(4) For the APU bleed-air ducts between FR42 and FR50:
(a) Install the access panels 147AB, 147EB, 147FB and 197BB.
(b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panels 147AB, 147EB, 147FB and 197BB.
(5) For the APU bleed-air ducts between the FR46 and FR47:
(17) For the APU bleed-air ducts between the FR70 and FR77:
(20) Remove the WARNING NOTICE(S).
Subtask 36-12-00-410-052-C ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) For the APU bleed-air ducts between FR35 and FR36:
(a) Install the access panels 191BB and 191EB.
(b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panels 191BB and 191EB.
(3) For the APU bleed-air ducts between FR36 and FR42:
(a) Install the access panel 191JB.
(b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panel 191JB.
(4) For the APU bleed-air ducts between FR42 and FR50:
(a) Install the access panels 147AB, 147EB, 147FB and 197BB.
(b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panels 147AB, 147EB, 147FB and 197BB.
(5) For the APU bleed-air ducts between the FR46 and FR47:
- Install the partition panel 151BW (Ref. AMM TASK 25-55-11-400-001).
- Install the access panel 151RW.
- Install the access panel 151CW.
- Install the access panel 151DW.
- Install the access panel 151EW.
- Install the access panel 151HW.
- Install the access panel 151JW.
- Install the access panel 161AW.
- Install the access panel 161BW.
- Install the access panel 161CW.
- Install the partition panel 161DW (Ref. AMM TASK 25-55-12-400-001).
(17) For the APU bleed-air ducts between the FR70 and FR77:
- Close the access door 312AR.
- Close the access door 314AR.
(20) Remove the WARNING NOTICE(S).
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) For the APU bleed-air ducts between FR35 and FR36:
(a) Install the access panels 191BB and 191EB.
(b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panels 191BB and 191EB.
(3) For the APU bleed-air ducts between FR36 and FR42:
(a) Install the access panel 191JB.
(b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panel 191JB.
(4) For the APU bleed-air ducts between FR42 and FR50:
(a) Install the access panels 147AB, 147EB, 147FB and 197BB.
(b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panels 147AB, 147EB, 147FB and 197BB.
(5) For the APU bleed-air ducts between the FR46 and FR53:
(14) For the APU bleed-air ducts between the FR70 and FR77:
(17) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) For the APU bleed-air ducts between FR35 and FR36:
(a) Install the access panels 191BB and 191EB.
(b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panels 191BB and 191EB.
(3) For the APU bleed-air ducts between FR36 and FR42:
(a) Install the access panel 191JB.
(b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panel 191JB.
(4) For the APU bleed-air ducts between FR42 and FR50:
(a) Install the access panels 147AB, 147EB, 147FB and 197BB.
(b) Remove the ACCESS PLATFORM 2M (6 FT) from below the access panels 147AB, 147EB, 147FB and 197BB.
(5) For the APU bleed-air ducts between the FR46 and FR53:
- Install the partition panel 151BW (Ref. AMM TASK 25-55-11-400-001).
- Install the access panel 151SW.
- Install the access panel 151TW.
- Install the access panel 151UW.
- Install the access panel 151VW.
- Install the access panel 161AW.
- Install the access panel 161BW.
- Install the access panel 161CW.
- Install the partition panel 161DW (Ref. AMM TASK 25-55-12-400-001).
(14) For the APU bleed-air ducts between the FR70 and FR77:
- Close the access door 312AR.
- Close the access door 314AR.
(17) Remove the WARNING NOTICE(S).