30-31 PROBE ICE PROTECTION
- PB.201 PROBE ICE PROTECTION - FAULT ISOLATION PROCEDURES
-
30-31-00-810-801-A
[8]
Loss of the PHC 1 -
30-31-00-810-802-A
[8]
Failure of the Pitot Probe (PHC1) -
30-31-00-810-803-A
[8]
Loss of the GND/FLT Information (PHC 1) -
30-31-00-810-804-A
[8]
Loss of the Power Supply for the Pitot Probe (PHC1) -
30-31-00-810-805-A
[8]
Failure of the L Static Probe (PHC1) -
30-31-00-810-806-A
[8]
Loss of the Power Supply for the Static Probe -
30-31-00-810-807-A
[8]
Failure of the R Static Probe (PHC1) -
30-31-00-810-808-A
[8]
Failure of the Angle of Attack Sensor (PHC 1) -
30-31-00-810-809-A
[8]
Loss of the Power Supply for the Angle of Attack Sensor -
30-31-00-810-810-A
[8]
Failure of the TAT Sensor -
30-31-00-810-811-A
[8]
Loss of the Power Supply for the TAT Sensor -
30-31-00-810-812-A
[8]
Loss of the PHC 2 -
30-31-00-810-813-A
[8]
Failure of the Pitot Probe (PHC 2) -
30-31-00-810-814-A
[8]
Loss of the GND/FLT Information (PHC 2) -
30-31-00-810-815-A
[8]
Loss of the Power Supply for the Pitot Probe (PHC 2) -
30-31-00-810-816-A
[8]
Failure of the L Static Probe (PHC 2) -
30-31-00-810-817-A
[8]
Loss of the Power Supply for the Static Probe (PHC 2) -
30-31-00-810-818-A
[8]
Failure of the R Static Probe (PHC 2) -
30-31-00-810-819-A
[8]
Failure of the Angle of Attack Sensor (PHC 2) -
30-31-00-810-820-A
[8]
Loss of the Power Supply for the Angle of Attack Sensor (PHC 2) -
30-31-00-810-821-A
[8]
Failure of the TAT Sensor (PHC 2) -
30-31-00-810-822-A
[8]
Loss of the Power Supply for the TAT Sensor -
30-31-00-810-823-A
[8]
Loss of the PHC 3 -
30-31-00-810-824-A
[8]
Failure of the Pitot Probe (PHC 3) -
30-31-00-810-825-A
[8]
Loss of the GND/FLT Information (PHC 3) -
30-31-00-810-826-A
[8]
Loss of the Power Supply for the Pitot Probe (PHC 3) -
30-31-00-810-827-A
[8]
Failure of the L Static Probe (PHC 3) -
30-31-00-810-828-A
[8]
Loss of the Power Supply for the Static Probe (PHC 3) -
30-31-00-810-829-A
[8]
Failure of the R Static Probe (PHC 3) -
30-31-00-810-830-A
[8]
Failure of the Angle of Attack Sensor (PHC 3) -
30-31-00-810-831-A
[8]
Loss of the Power Supply for the Angle of Attack Sensor (PHC 3) -
30-31-00-810-832-A
[8]
Loss of the Validation Input (PHC 1) -
30-31-00-810-833-A
[8]
Loss of the Validation Input (PHC 2) -
30-31-00-810-834-A
[8]
Loss of the Validation Input (PHC 3) -
30-31-00-810-835-A
[8]
Loss of the Input Discrete (ENG 1/ENG 2) (PHC 1) -
30-31-00-810-836-A
[8]
Loss of the Input Discrete (ENG 1/ENG 2) (PHC 2) -
30-31-00-810-837-A
[8]
Loss of the Input Discrete (ENG 1/ENG 2) (PHC 3) -
30-31-00-810-838-A
[8]
Loss of the PHC 1 (Class 3 Faults) -
30-31-00-810-839-A
[8]
Loss of the PHC 2 (Class 3 Faults) -
30-31-00-810-840-A
[8]
Loss of the PHC 3 (Class 3 Faults) -
30-31-00-810-841-A
[8]
Loss of the Pitot Probe Output-Discrete from the PHC 1 -
30-31-00-810-842-A
[8]
Loss of the Angle-of-Attack Sensor Output-Discrete from the PHC 1 -
30-31-00-810-843-A
[8]
Loss of the L Static Probe Output-Discrete from the PHC 1 -
30-31-00-810-844-A
[8]
Loss of the R Static Probe Output-Discrete from the PHC 1 -
30-31-00-810-845-A
[8]
Loss of the TAT Sensor Output-Discrete from the PHC 1 -
30-31-00-810-846-A
[8]
Loss of the Pitot Probe Output Discrete from the PHC 2 -
30-31-00-810-847-A
[8]
Loss of the Angle-of-Attack Sensor Output-Discrete from the PHC 2 -
30-31-00-810-848-A
[8]
Loss of the L Static Probe Output-Discrete from the PHC 2 -
30-31-00-810-849-A
[8]
Loss of the R Static Probe Output-Discrete from the PHC 2 -
30-31-00-810-850-A
[8]
Loss of the TAT Sensor Output-Discrete from the PHC 2 -
30-31-00-810-851-A
[8]
Loss of the Pitot Probe Output-Discrete from the PHC 3 -
30-31-00-810-852-A
[8]
Loss of the Angle-of-Attack Sensor Output-Discrete from the PHC 3 -
30-31-00-810-853-A
[8]
Loss of the L Static Probe Output-Discrete from the PHC 3 -
30-31-00-810-854-A
[8]
Loss of the R Static Probe Output-Discrete from the PHC 3 -
30-31-00-810-855-A
[8]
Loss of the TAT Sensor Output-Discrete from the PHC 1 to the ADIRU 3 -
30-31-00-810-856-A
[8]
Loss of the LGCIU 1 or the LGCIU 2 -
30-31-00-810-860-A
[8]
Nuisance Warning Shown on the Post Flight Report (PFR) -
30-31-00-810-861-A
[8]
Failure of the Pitot Probe without Maintenance Message on the Post Flight Report -
30-31-00-810-862-A
[8]
Failure of the PHC 1 -
30-31-00-810-863-A
[8]
Failure of the PHC 2 -
30-31-00-810-864-A
[8]
Failure of the PHC 3 -
30-31-00-810-865-A
[8]
Failure of the Pitot Probes (PHC 1 and PHC 2) -
30-31-00-810-866-A
[8]
Failure of the Pitot Probes (PHC 1 and PHC 3) -
30-31-00-810-867-A
[8]
Failure of the Pitot Probes (PHC 2 and PHC 3) -
30-31-00-810-868-A
[8]
Failure of the Pitot Probes (PHC 1, PHC 2 and PHC 3) -
30-31-00-810-869-A
[8]
Loss of the GND/FLT Information (PHC 1 and PHC 2) -
30-31-00-810-870-A
[8]
Loss of the GND/FLT Information (PHC 1 and PHC 3) -
30-31-00-810-871-A
[8]
Loss of the GND/FLT Information (PHC 2 and PHC 3) -
30-31-00-810-872-A
[8]
Loss of the GND/FLT Information (PHC 1, PHC 2 and PHC 3) -
30-31-00-810-873-A
[8]
Nuisance Warning Shown on the Post Flight Report (PFR) -
30-31-00-810-874-A
[8]
Loss of the Captain Left STAT Output Discrete from the PHC 1 -
30-31-00-810-875-A
[8]
Loss of the Captain Right STAT Output Discrete from the PHC 1 -
30-31-00-810-876-A
[8]
Loss of the Captain AOA Output Discrete from the PHC 1 -
30-31-00-810-877-A
[8]
Loss of the F/O Left STAT Output Discrete from the PHC 2 -
30-31-00-810-878-A
[8]
Loss of the F/O Right STAT Output Discrete from the PHC 2 -
30-31-00-810-879-A
[8]
Loss of the F/O AOA Output Discrete from the PHC 2 -
30-31-00-810-880-A
[8]
Loss of the Standby Left STAT Output Discrete from the PHC 3 -
30-31-00-810-881-A
[8]
Loss of the Standby Right STAT Output Discrete from the PHC 3 -
30-31-00-810-882-A
[8]
Loss of the Standby AOA Output Discrete from the PHC 3
-
30-31-00-810-801-A
[8]