W DOC AIRBUS | TSM A320F

Loss of the GND/FLT Information (PHC 1 and PHC 2)


TASK 30-31-00-810-869-A
Loss of the GND/FLT Information (PHC 1 and PHC 2)


1. Possible Causes
  • PROX SNSR-L L/G EXT, SYS 1 [21GA]
  • PROX SNSR-L L/G EXT, SYS 2 [23GA]
  • PROX SNSR-R L/G EXT, SYS 1 [20GA]
  • PROX SNSR-R L/G EXT, SYS 2 [22GA]
  • LGCIU-1 [5GA1]
  • LGCIU-2 [5GA2]
  • C/B-L/G/LGCIU/SYS1/NORM [1GA]
  • C/B-HYDRAULIC/LGCIU/SYS2 [2GA]
  • C/B-HYDRAULIC/LGCIU/SYS1/GRND SPLY [52GA]
  • PHC-1 [6DA1]
  • PHC-2 [6DA2]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 30-31-00-710-001
Operational Test of the Probe Ice Protection
ASM 303101
ASM 303102
AMM 30-31-34-000-002
Removal of the Probe Heat Computer (PHC)
AMM 30-31-34-400-002
Installation of the Probe Heat Computer (PHC)
AMM 32-00-00-860-001
Flight Configuration Precautions with Electrical Power
AMM 32-31-71-000-001
Removal of the LGCIU
AMM 32-31-71-400-001
Installation of the LGCIU
AMM 32-31-73-000-001
Removal of the MLG Proximity-Sensors
AMM 32-31-73-200-001
Inspection of the MLG Proximity Sensor and Target Clearances
AMM 32-31-73-400-001
Installation of the MLG Proximity-Sensors
3. Fault Confirmation
Subtask 30-31-00-710-179-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the operational test of the probe ice protection AMM 30-31-00-710-001.
4. Fault Isolation
Subtask 30-31-00-810-121-A ** ON A/C NOT FOR ALL
A. If the ECAM warning message ANTI ICE CAPT+F/O PITOT comes into view:
   (1) If the fault continues:
   (2) If the fault continues:
  • Do a check for ground signal at pin A/<E, pin A/<D and pin A/<I of the PHC 1 (6DA1) and PHC 2 (6DA2) ASM 303101 and ASM 303102.
     (a) If there is no ground signal:
     (b) If there is a ground signal:
Simulate the flight configuration:
  • Make sure that you obey the flight configuration precautions AMM 32-00-00-860-001.
  • On the overhead circuit breaker panel 49VU, open the C/B-L/G/LGCIU/SYS1/NORM [1GA] circuit breaker.
  • On the rear circuit breaker panel 121VU, open the C/B-HYDRAULIC/LGCIU/SYS2 [2GA] and C/B-HYDRAULIC/LGCIU/SYS1/GRND SPLY [52GA] circuit breakers.
  • Do a check for ground signal at pin A/<E, pin A/<D and pin A/<I of the PHC 1 (6DA1) and PHC 2 (6DA2) ASM 303101 and ASM 303102.
       1 If there is a ground signal:
       2 If there is no ground signal:
         a If the fault continues:
  • Do a check and repair the wiring :
    . From the PHC 1 (6DA1) pin A/<E to the LGCIU 1 (5GA1) pin AB/14A and/or from the PHC 1 (6DA1) pin A/<D to the LGCIU 2 (5GA2) pin AB/14A ASM 303101.
    . From the PHC 2 (6DA2) pin A/<E to the LGCIU 1 (5GA1) pin AB/14E and/or from the PHC 2 (6DA2) pin A/<D to the LGCIU 2 (5GA2) pin AB/14E ASM 303102.
Subtask 30-31-00-710-180-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.