1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 30-31-00-720-050-A
Subtask 30-31-00-810-110-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:38 UTC
Failure of the Pitot Probe without Maintenance Message on the Post Flight Report
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 30-31-00-810-802-A | Failure of the Pitot Probe (PHC1) |
Subtask 30-31-00-720-050-A
A. Test
Not Applicable
4. Fault IsolationNot Applicable
Subtask 30-31-00-810-110-A
A. If the fault symptom is identified by the crew observation:
ANTI ICE CAPT PITOT or ANTI ICE F/O PITOT or ANTI ICE STBY PITOT warning on the upper ECAM DU without maintenance message on the Post Flight Report, the related pitot probe is defective.
(1) Do the trouble shooting procedure (Ref. TSM TASK 30-31-00-810-802)
ANTI ICE CAPT PITOT or ANTI ICE F/O PITOT or ANTI ICE STBY PITOT warning on the upper ECAM DU without maintenance message on the Post Flight Report, the related pitot probe is defective.