Failure of the Pitot Probe (PHC1)
TASK 30-31-00-810-802-A
Failure of the Pitot Probe (PHC1)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 30-31-00-710-052-A 4. Fault Isolation
Subtask 30-31-00-810-051-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:29:34 UTC
Failure of the Pitot Probe (PHC1)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 30-31-00-710-001 | Operational Test of the Probe Ice Protection |
| ASM 303101 | |
| AMM 30-31-34-000-002 | Removal of the Probe Heat Computer (PHC) |
| AMM 30-31-34-400-002 | Installation of the Probe Heat Computer (PHC) |
| AMM 34-11-15-000-001 | Removal of the Pitot Probe |
| AMM 34-11-15-400-001 | Installation of the Pitot Probe |
Subtask 30-31-00-710-052-A 4. Fault Isolation
Subtask 30-31-00-810-051-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message PITOT PROBE 9DA1:
(a) Replace the PROBE-PITOT, 1 [9DA1] , AMM 34-11-15-000-001 and AMM 34-11-15-400-001.
(2) If the resistance is between 32,3 ohms and 35,7 ohms at a temperature of 20 deg.C (68 deg.F):
(a) Replace the PHC-1 [6DA1] , AMM 30-31-34-000-002 and AMM 30-31-34-400-002.
(b) If the fault continues:
Subtask 30-31-00-810-051-D ** ON A/C NOT FOR ALL - Disconnect the connector from the pitot probe 1 (9DA1) and do a check of the resistance between pins A/B and A/C.
(a) Replace the PROBE-PITOT, 1 [9DA1] , AMM 34-11-15-000-001 and AMM 34-11-15-400-001.
(2) If the resistance is between 32,3 ohms and 35,7 ohms at a temperature of 20 deg.C (68 deg.F):
(a) Replace the PHC-1 [6DA1] , AMM 30-31-34-000-002 and AMM 30-31-34-400-002.
(b) If the fault continues:
- Do a check and repair the
wiring from the PHC 1 (6DA1) to the pitot probe 1 (9DA1) , pin A/H to pin A/B ASM 303101.
A. If the test gives the maintenance message PITOT PROBE 9DA1:
(a) Replace the PROBE-PITOT, 1 [9DA1] , AMM 34-11-15-000-001 and AMM 34-11-15-400-001.
(2) If the resistance is between 24 ohms and 34 ohms at a temperature of 20 deg.C (68 deg.F):
(a) Replace the PHC-1 [6DA1] , AMM 30-31-34-000-002 and AMM 30-31-34-400-002.
(b) If the fault continues:
Subtask 30-31-00-710-053-A - Disconnect the connector from the pitot probe 1 (9DA1) and do a check of the resistance between pins A/B and A/C.
(a) Replace the PROBE-PITOT, 1 [9DA1] , AMM 34-11-15-000-001 and AMM 34-11-15-400-001.
(2) If the resistance is between 24 ohms and 34 ohms at a temperature of 20 deg.C (68 deg.F):
(a) Replace the PHC-1 [6DA1] , AMM 30-31-34-000-002 and AMM 30-31-34-400-002.
(b) If the fault continues:
- Do a check and repair the
wiring from the PHC 1 (6DA1) to the pitot probe 1 (9DA1) , pin A/H to pin A/B ASM 303101.
B. Do the operational test given in Para. 3.