Failure of the Pitot Probe (PHC1)


TASK 30-31-00-810-802-A
Failure of the Pitot Probe (PHC1)


1. Possible Causes
  • PROBE-PITOT, 1 [9DA1]
  • PHC-1 [6DA1]
  • wiring from the PHC 1 (6DA1) to the pitot probe 1 (9DA1)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 30-31-00-710-001
Operational Test of the Probe Ice Protection
ASM 303101
AMM 30-31-34-000-002
Removal of the Probe Heat Computer (PHC)
AMM 30-31-34-400-002
Installation of the Probe Heat Computer (PHC)
AMM 34-11-15-000-001
Removal of the Pitot Probe
AMM 34-11-15-400-001
Installation of the Pitot Probe
3. Fault Confirmation
Subtask 30-31-00-710-052-A
A. Test
   (1) Do the operational test of the probe ice protection AMM 30-31-00-710-001.
4. Fault Isolation
Subtask 30-31-00-810-051-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message PITOT PROBE 9DA1:
  • Disconnect the connector from the pitot probe 1 (9DA1) and do a check of the resistance between pins A/B and A/C.
   (1) If the resistance is more than 35,7 ohms (open circuit) or less than 32,3 ohms (short circuit) at a temperature of 20 deg.C (68 deg.F):
     (a) Replace the PROBE-PITOT, 1 [9DA1] , AMM 34-11-15-000-001 and AMM 34-11-15-400-001.
   (2) If the resistance is between 32,3 ohms and 35,7 ohms at a temperature of 20 deg.C (68 deg.F):
     (a) Replace the PHC-1 [6DA1] , AMM 30-31-34-000-002 and AMM 30-31-34-400-002.
     (b) If the fault continues:
  • Do a check and repair the wiring from the PHC 1 (6DA1) to the pitot probe 1 (9DA1), pin A/H to pin A/B ASM 303101.
Subtask 30-31-00-810-051-D ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message PITOT PROBE 9DA1:
  • Disconnect the connector from the pitot probe 1 (9DA1) and do a check of the resistance between pins A/B and A/C.
   (1) If the resistance is more than 34 ohms (open circuit) or less than 24 ohms (short circuit) at a temperature of 20 deg.C (68 deg.F):
     (a) Replace the PROBE-PITOT, 1 [9DA1] , AMM 34-11-15-000-001 and AMM 34-11-15-400-001.
   (2) If the resistance is between 24 ohms and 34 ohms at a temperature of 20 deg.C (68 deg.F):
     (a) Replace the PHC-1 [6DA1] , AMM 30-31-34-000-002 and AMM 30-31-34-400-002.
     (b) If the fault continues:
  • Do a check and repair the wiring from the PHC 1 (6DA1) to the pitot probe 1 (9DA1), pin A/H to pin A/B ASM 303101.
Subtask 30-31-00-710-053-A
B. Do the operational test given in Para. 3.