W DOC AIRBUS | TSM A320F

Loss of the TAT Sensor Output-Discrete from the PHC 2


TASK 30-31-00-810-850-A
Loss of the TAT Sensor Output-Discrete from the PHC 2


1. Possible Causes
  • PHC-2 [6DA2]
  • wiring from the PHC 2 (6DA2) to the ADIRU 2 (1FP2)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 34-13-00-810-910-A
Loss of the TAT Sensor 2 Input on the ADR2
AMM 30-31-00-710-001
Operational Test of the Probe Ice Protection
ASM 303102
AMM 30-31-34-000-002
Removal of the Probe Heat Computer (PHC)
AMM 30-31-34-400-002
Installation of the Probe Heat Computer (PHC)
AMM 34-13-00-740-002
INTERFACE TEST of the ADR
ASM 341302
3. Fault Confirmation
Subtask 30-31-00-710-148-A
A. Test
   (1) Do the operational test of the probe ice protection AMM 30-31-00-710-001.
4. Fault Isolation
Subtask 30-31-00-810-099-A
A. If the test gives the maintenance message CHECK ADIRU2 TAT PHC2 INTERFACE:
  • do a check for ground at pin A/<A of the PHC 2 (6DA2) ASM 303102.
   (1) If there is no ground:
     (a) If the fault continues:
  • do a check and repair the wiring from the PHC 2 (6DA2) to the ADIRU 2 (1FP2) pin A/<A to pin AA/4F ASM 341302.
     (b) If the fault continues:
Subtask 30-31-00-710-149-A
B. Do the operational test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:29:38 UTC