W DOC AIRBUS | TSM A320F

Loss of the TAT Sensor 2 Input on the ADR2


TASK 34-13-00-810-910-A
Loss of the TAT Sensor 2 Input on the ADR2


1. Possible Causes
  • SENSOR-TAT, 2 [11FP2]
  • ADIRU-2 [1FP2]
  • wiring from the TAT sensor 2 to the ADIRU2
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 30-31-00-810-803-A
Loss of the GND/FLT Information (PHC 1)
AMM 30-31-00-710-001
Operational Test of the Probe Ice Protection
ASM 341102
AMM 34-11-18-000-001
Removal of the TAT Sensor
AMM 34-11-18-400-001
Installation of the TAT Sensor
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-13-00-740-002
INTERFACE TEST of the ADR
3. Fault Confirmation
Subtask 34-13-00-740-219-A
A. Test
Do the Interface test of the ADR (system 2) AMM 34-13-00-740-002.
4. Fault Isolation
Subtask 34-13-00-810-159-B
A. If the test gives the maintenance message TAT SENSOR (11FP2)/ ADIRU2 (1FP2):
   (1) If you cannot start the test:
   (2) If the test is OK:
     (a) If the fault continues:
       1 If the fault continues:
  • do a check and repair the wiring from the TAT sensor 2 to the ADIRU2 ASM 341102.
Subtask 34-13-00-740-220-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:40:01 UTC