Loss of the TAT Sensor 2 Input on the ADR2
TASK 34-13-00-810-910-A
Loss of the TAT Sensor 2 Input on the ADR2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-00-740-219-A 4. Fault Isolation
Subtask 34-13-00-810-159-B
[Rev.8 from Aug 2018]
2026.04.04 04:32:27 UTC
Loss of the TAT Sensor 2 Input on the ADR2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 30-31-00-810-803-A | Loss of the GND/FLT Information (PHC 1) |
| AMM 30-31-00-710-001 | Operational Test of the Probe Ice Protection |
| ASM 341102 | |
| AMM 34-11-18-000-001 | Removal of the TAT Sensor |
| AMM 34-11-18-400-001 | Installation of the TAT Sensor |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| AMM 34-13-00-740-002 | INTERFACE TEST of the ADR |
Subtask 34-13-00-740-219-A 4. Fault Isolation
Subtask 34-13-00-810-159-B
A. If the test gives the maintenance message TAT SENSOR (11FP2)/ ADIRU2 (1FP2):
Subtask 34-13-00-740-220-A - do the operational test of the probe ice protection AMM 30-31-00-710-001.
- do the procedure that follows (Ref. TSM TASK 30-31-00-810-803).
- replace the SENSOR-TAT, 2 [11FP2] AMM 34-11-18-000-001 and AMM 34-11-18-400-001.
- replace the ADIRU-2 [1FP2] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- do a check and repair the wiring from the TAT sensor 2 to the ADIRU2 ASM 341102.
B. Do the test given in Para. 3.