Loss of the GND/FLT Information (PHC 2)
TASK 30-31-00-810-814-A
Loss of the GND/FLT Information (PHC 2)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 30-31-00-710-076-A 4. Fault Isolation
Subtask 30-31-00-810-063-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:29:35 UTC
Loss of the GND/FLT Information (PHC 2)
1. Possible Causes
- LGCIU-1 [5GA1]
- C/B-L/G/LGCIU/SYS1/NORM [1GA]
- C/B-HYDRAULIC/LGCIU/SYS2 [2GA]
- C/B-HYDRAULIC/LGCIU/SYS1/GRND SPLY [52GA]
- PHC-2 [6DA2]
- LGCIU-2 [5GA2]
- wiring
- ADIRU-2 [1FP2]
- PROX SNSR-R L/G EXT, SYS 1 [20GA]
- PROX SNSR-R L/G EXT, SYS 2 [22GA]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 30-31-00-710-001 | Operational Test of the Probe Ice Protection |
| ASM 303102 | |
| AMM 30-31-34-000-002 | Removal of the Probe Heat Computer (PHC) |
| AMM 30-31-34-400-002 | Installation of the Probe Heat Computer (PHC) |
| AMM 32-00-00-860-001 | Flight Configuration Precautions with Electrical Power |
| AMM 32-31-71-000-001 | Removal of the LGCIU |
| AMM 32-31-71-400-001 | Installation of the LGCIU |
| AMM 32-31-73-000-001 | Removal of the MLG Proximity-Sensors |
| AMM 32-31-73-200-001 | Inspection of the MLG Proximity Sensor and Target Clearances |
| AMM 32-31-73-400-001 | Installation of the MLG Proximity-Sensors |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
Subtask 30-31-00-710-076-A 4. Fault Isolation
Subtask 30-31-00-810-063-B ** ON A/C NOT FOR ALL
A. If the ECAM warning message ANTI ICE F/O PITOT comes into view only or associated with the maintenance message CHECK LGCIU - PHC2 INTERFACE and if the loss of GND/FLT information occurred:
Simulate flight configuration:
Subtask 30-31-00-810-063-C ** ON A/C NOT FOR ALL - make sure that there is no maintenance message related to the landing gear system (Ref. ATA 32).
- do the related trouble shooting.
- do the inspection of the MLG proximity sensor and target clearances AMM 32-31-73-200-001.
- do a check for ground at pin A/E and/or pin A/D and/or pin A/I of the PHC 2 (6DA2).
- replace the LGCIU-1 [5GA1] AMM 32-31-71-000-001 and AMM 32-31-71-400-001.
Simulate flight configuration:
- on the pannel 49VU, open the C/B-L/G/LGCIU/SYS1/NORM [1GA] circuit breaker.
- on the pannel 121VU, open the C/B-HYDRAULIC/LGCIU/SYS2 [2GA] and C/B-HYDRAULIC/LGCIU/SYS1/GRND SPLY [52GA] circuit breakers.
NOTE: Make sure you obey the flight configuration precautions AMM 32-00-00-860-001.
- do a check for ground at PIN A/E and/or PIN A/D and/or PIN A/I of the PHC2 (6DA2).
- replace the LGCIU-1 [5GA1] , AMM 32-31-71-000-001 and AMM 32-31-71-400-001.
- replace the PHC-2 [6DA2] , AMM 30-31-34-000-002 and AMM 30-31-34-400-002.
- replace the LGCIU-2 [5GA2] .
- do a check and repair the wiring from the PHC 2 pin A/E to the LGCIU 1 pin AB/14E and/or from the PHC 2 pin A/D to the LGCIU 2 pin AB/14E ASM 303102.
- replace the ADIRU-2 [1FP2] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
A. If the ECAM warning message ANTI ICE F/O PITOT comes into view only or associated with the maintenance message CHECK LGCIU - PHC2 INTERFACE and if the loss of GND/FLT information occurred:
Simulate flight configuration:
Subtask 30-31-00-710-077-A - make sure that there is no maintenance message related to the landing gear system (Ref. ATA 32).
- do the related trouble shooting.
- do the inspection of the MLG proximity sensor and target clearances AMM 32-31-73-200-001.
- replace the PROX SNSR-R L/G EXT, SYS 1 [20GA] and PROX SNSR-R L/G EXT, SYS 2 [22GA] , AMM 32-31-73-000-001 and AMM 32-31-73-400-001.
- do a check for ground at pin A/E and/or pin A/D and/or pin A/I of the PHC 2 (6DA2).
- replace the LGCIU-1 [5GA1] AMM 32-31-71-000-001 and AMM 32-31-71-400-001.
Simulate flight configuration:
- on the pannel 49VU, open the C/B-L/G/LGCIU/SYS1/NORM [1GA] circuit breaker.
- on the pannel 121VU, open the C/B-HYDRAULIC/LGCIU/SYS2 [2GA] and C/B-HYDRAULIC/LGCIU/SYS1/GRND SPLY [52GA] circuit breakers.
NOTE: Make sure you obey the flight configuration precautions AMM 32-00-00-860-001.
- do a check for ground at PIN A/E and/or PIN A/D and/or PIN A/I of the PHC2 (6DA2).
- replace the LGCIU-1 [5GA1] , AMM 32-31-71-000-001 and AMM 32-31-71-400-001.
- replace the PHC-2 [6DA2] , AMM 30-31-34-000-002 and AMM 30-31-34-400-002.
- replace the LGCIU-2 [5GA2] .
- do a check and repair the wiring from the PHC 2 pin A/E to the LGCIU 1 pin AB/14E and/or from the PHC 2 pin A/D to the LGCIU 2 pin AB/14E ASM 303102.
- replace the ADIRU-2 [1FP2] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
B. Do the operational test given in Para. 3.